Permit Number: TR-ROW-0126-00095
Parcel: 123100070

Address:
1516 E SENECA ST

Review Status: Requires Resubmit

Review Details: RIGHT-OF-WAY REVIEW v.1

Permit Number - TR-ROW-0126-00095
Review Name: RIGHT-OF-WAY REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/29/2026 ROW Engineering Review - Standard PENDING ASSIGNMENT
01/29/2026 Transportation Application Review Express REQUIRES RESUBMIT Please attach a Google aerial view showing the marked location where work is being conducted for the site plan. Additionally, please add the correct dimensions for the curb cut. Note that the maximum allowable curb cut width is 20 feet total, including wings. Please also attach a commentary note in the attachment describing the scope of work and dimensions.
Below are the curb cut requirements for residential zoned areas:

Minimum curb cut width: 10 feet
Maximum curb cut width: 20 feet
Maximum curb cut width for two adjoining properties: 30 feet
Minimum distance between curb cuts: 12 feet
Minimum distance from street light standards or catch basins: 5 feet
Minimum distance from fire hydrant or city water hydrant: 20 feet
Minimum distance from end of curb return: 4 feet

Please revise the site plan accordingly and resubmit for review.