Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TR-ROW-0126-00095
Parcel: 123100070

Address:
1516 E SENECA ST

Review Status: Requires Resubmit

Review Details: RIGHT-OF-WAY REVIEW v.5

Permit Number - TR-ROW-0126-00095
Review Name: RIGHT-OF-WAY REVIEW v.5
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/27/2026 ROW Engineering Review - Standard REQUIRES RESUBMIT DTM Eng. Review Comments -
Redline Notes have been placed on 2 Aerial image file and 1 Cad drawing file all marked for Require Resubmittal status. Also refer to Email as i have sent you a copy of the Redline file for direct reference.
Redline Comments ---
Combine Driveway not to exceed 30' - Minimum Driveway width for 1516 E Seneca St
New build would be 10' min width.

City of Tucson Codes of Ordinances Chapter 25 - Streets and Sidewalks
Sec. 25-38. Special requirements in residential districts.
(a) Curb cuts and driveways shall conform to the following requirements in all residential zoned districts:
Minimum curb cut width . . . . . 10 feet
Maximum curb cut width . . . . . 20 feet
Maximum curb cut width for 2 adjoining properties . . . . . 30 feet
Minimum distance between curb cuts . . . . . 12 feet
Minimum distance of curb cut from street light standards, or catch basins . . . . . 5 feet
Minimum distance of curb cut from a fire hydrant of city water hydrant . . . . . 20 feet
Minimum distance of curb cut from end of a curb return . . . . . 4 feet
OR
from a curb line or a cross street at a street intersection, whichever is more restrictive . . . . . 20 feet
03/25/2026 Transportation Application Review Express REVIEW COMPLETED