Permit Review Detail
Review Status: Requires Resubmit
Review Details: RIGHT-OF-WAY REVIEW v.5
Permit Number - TR-ROW-0126-00095
Review Name: RIGHT-OF-WAY REVIEW v.5
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/27/2026 | ROW Engineering Review - Standard | REQUIRES RESUBMIT | DTM Eng. Review Comments - Redline Notes have been placed on 2 Aerial image file and 1 Cad drawing file all marked for Require Resubmittal status. Also refer to Email as i have sent you a copy of the Redline file for direct reference. Redline Comments --- Combine Driveway not to exceed 30' - Minimum Driveway width for 1516 E Seneca St New build would be 10' min width. City of Tucson Codes of Ordinances Chapter 25 - Streets and Sidewalks Sec. 25-38. Special requirements in residential districts. (a) Curb cuts and driveways shall conform to the following requirements in all residential zoned districts: Minimum curb cut width . . . . . 10 feet Maximum curb cut width . . . . . 20 feet Maximum curb cut width for 2 adjoining properties . . . . . 30 feet Minimum distance between curb cuts . . . . . 12 feet Minimum distance of curb cut from street light standards, or catch basins . . . . . 5 feet Minimum distance of curb cut from a fire hydrant of city water hydrant . . . . . 20 feet Minimum distance of curb cut from end of a curb return . . . . . 4 feet OR from a curb line or a cross street at a street intersection, whichever is more restrictive . . . . . 20 feet |
||
| 03/25/2026 | Transportation Application Review Express | REVIEW COMPLETED |