Permit Number: TR-ROW-0126-00082
Parcel: 133450360

Review Status: Requires Resubmit

Review Details: RIGHT-OF-WAY REVIEW v.2

Permit Number - TR-ROW-0126-00082
Review Name: RIGHT-OF-WAY REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/02/2026 ROW Engineering Review - Standard REQUIRES RESUBMIT Review Driveway location and provide updated related documentation meeting
1) PAG 206 Standard detail - Find attached document.
2) Meet City Chapter 25 requirements for Residential Curb cuts -
Sec. 25-38. Special requirements in residential districts.
(a) Curb cuts and driveways shall conform to the following requirements in all residential zoned districts:
Minimum curb cut width . . . . . 10 feet
Maximum curb cut width . . . . . 20 feet
Maximum curb cut width for 2 adjoining properties . . . . . 30 feet
Minimum distance between curb cuts . . . . . 12 feet
Minimum distance of curb cut from street light standards, or catch basins . . . . . 5 feet
Minimum distance of curb cut from a fire hydrant of city water hydrant . . . . . 20 feet
Minimum distance of curb cut from end of a curb return . . . . . 4 feet
OR
from a curb line or a cross street at a street intersection, whichever is more restrictive . . . . . 20 feet
03/02/2026 Transportation Application Review Express REVIEW COMPLETED