| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/10/2023 | Transportation Landscape Review | APPROVED | |||
| 11/09/2023 | Transportation Maps and Records Review | NOT REQUIRED | Review time expired - JV | ||
| 11/09/2023 | DTM Electrical | REQUIRES RESUBMIT | DTM Electrical comments have been added on separate PDF in attachments. | ||
| 11/09/2023 | Floodplain Administration Review | REQUIRES RESUBMIT | Construction Plan Provide more details existing and proposed location for relocating Rain Gauge Provide Drainage Easement on site on Development Plan Add construction note on Plan View A/V sensor and strainer in manhole detail to coordinate with COT Stormwater team for installation. |
||
| 11/09/2023 | PIA Engineering Review | REQUIRES RESUBMIT | Construction Plan Show 2% max slope in driveways, 6" concrete recommended for sidewalk area Storm drain conflict with curb, provide separation and depth Show onsite drainage structures RCP Slope should be 0.1% minimum per drainage manual add Plan number for existing storm drains Add class type for new RCPs Correct PIA number (TR-PIA-0423-00015) on Coversheet Reference Record Document ## for Easement Dedication |
||
| 11/09/2023 | DTM Electrical | REVIEW COMPLETED | |||
| 10/16/2023 | Traffic Engineering Review | REVIEW COMPLETED | Signing and striping comments from previous submittal have been addressed appropriately. |