| Fire New Construction | REVIEW COMPLETED | TP-PRE-1223-00389 • Pre-Application Conference Review v1 • 2451 S CAMPBELL AV TUCSON, AZ 85713: Based on the information provided, TFD has no comments at this time. Questions: patricia.shelton@tucsonaz.gov / 520.837.7082 |
|||
| ROW Engineering Review | REVIEW COMPLETED | TP-PRE-1223-00389 2451 S. Campbell Ave. Comments: 1. Any existing curb or sidewalk that is non-compliant will be reconstructed to meet current standards. 2. New curb access ramp(s) to be constructed at the SE corner of Campbell Ave/ 34th St. per P.A.G. standard 207. 3. Tie-in and continue with New Concrete Sidewalk along 34th St for the length of the property frontage, per P.A.G. standard 200. 4. When DP is submitted, show the ingress/ egress of each duplex, i.e. Driveways or driveway aprons. 5. Protect in place existing catch basins. 6. Protect in place or relocate accordingly, existing regulatory or warning signs. David Stiffey DTM Project Coordinator David.Stiffey@tucsonaz.gov |
|||
| Site Engineering | REVIEW COMPLETED | 1. This land division can not be facilitated via lot splits. 2. Approval from PCWW will be required - the proposed sewer line may need to be a public sewer main that meets their requirements. 3. Separate utility permit will be required for installation of sewer. 4. The Final Plat will need to comply with 2-07.5.0 of the Administrative Manual. See 2-07.5.5. for survey information required on the final plat - Basis of Bearing, section tie, etc. 5. Contact building safety regarding Overhead electrical service. 6. Contact building safety regarding HCS connections to new sewer line. Joshua Garcia joshua.garcia@tucsonaz.gov |
|||
| Site Landscape | REVIEW COMPLETED | Landscape/NPPO has no concerns about the proposed lot split. If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov |
|||
| Site Zoning | REVIEW COMPLETED | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Nicholas Martell, Principal Planner PROJECT: Thursday Pre-submittal meeting - TP-PRE-1223-00389 Address: 2451 S CAMPBELL AV Parcel: 13005303H Zoning: R-2, C-1 Existing Use: Vacant Proposed Use: Single Family-Duplex Subdivision TRANSMITTAL DATE: February 29, 2024 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 – Development Package/Tentative Plat. The Development Package is a separate submittal from the building permits, and the building permits cannot be approved until the Development Package is approved. 2. Development must comply with Administrative Manual Section 2-07 FINAL PLAT 3. Single Family-Residential is an allowed use in both zones: a. R-2 allowed with adherence to 4.9.7.B.6, .9, & .10 b. C-1 allowed without use-specific standards. 4. Parking is calculated as follows (Table 7.4.4-1 UDC): 2 spaces per dwelling unit plus visitor parking required at a ratio of 0.25 space per unit. 5. Perimeter yard setbacks are measured as follows: a. R-2: A residential use adjacent to a residential zone – 6’ or 2/3(H). Adjacent to a non-residential zone -10’ or ¾ (H). b. C-1: A residential use adjacent to a residential or nonresidential zone – 10’ or ¾ (H). 6. The maximum height of a duplex in either zone is 25’ building height (UDC TABLE 6.3-4.A and TABLE 6.3-2.B) 7. The stretch of South Campbell where the work is being proposed is considered a local street. Per 6.4.5.C of the UDC, For single-family and duplex development, the minimum required front street perimeter yard is 20 feet measured from the street property line. 8. Ensure access standards found in section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met. 9. Ensure bicycle parking is provided per article 7.4.8 of the UDC. 10. Ensure compliance with UDC 7.4.6: a. Per 7.4.6.K “Use of Street or Alley for Maneuvering Area A street or alley cannot be used for maneuvering directly into or from any parking space located wholly or partially outside the public right-of-way , except as follows: 1. The following uses are permitted to use a street or alley for access and maneuvering: a. Residential uses (including, but not limited to, single-family dwellings, mobile home dwellings, duplexes on individual lots, multifamily development, and Residential Care Services) that provide four or fewer off-street motor vehicle parking spaces. 11. The density calculations appear compliant with the R-2 and C-1 zones. The R-2 zone allows 15 units per acre, per TABLE 6.3-2.A. The C-1 Zone allows 36 units per acre per TABLE 6.3-4.A. 12. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions about this transmittal, contact me at Nicholas.Martell@tucsonaz.gov |
|||
| TW New Area Development | REVIEW COMPLETED | TP-PRE-1223-00389 - Pre-Application Conference Review v1 – 2451 S CAMPBELL AV Tucson Water has no objections to the proposed development and offers the following comments for your convenience: 1. The water meters may not be manifolded together as shown on the submitted drawing. Each water meter will need to have it own, separate water service line to the water main. 2. The water meters must be located at least 2’ away from the property corners. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |