Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: TP-PRE-1222-00064
Parcel: 11105063G

Review Status: Approved

Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1

Plan Number - TP-PRE-1222-00064
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
Fire New Construction REVIEW COMPLETED Fire sprinkler plans shall be submitted to and a permit obtained from TFD
Fire alarm plans shall be submitted to and a permit obtained from TFD
Questions:
Jennifer Peel-Davis
Tucson Fire Department
Fire Plans Examiner
Fire Inspector I, II and Fire Alarm Plans Examiner
Jennifer.Peel-Davis@Tucsonaz.gov
Desk: 520-837-7033
Site Engineering REVIEW COMPLETED TP-PRE-1222-00064
3544 E Fort Lowell Rd

1. First Flush retention will be required based on the new impervious area. Please refer to the updated retention/detention manual at: https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-final-201406-manual.pdf With amendments listed at: https://www.tucsonaz.gov/files/pdsd/codes/Detention_Retention_Manual_Tech_Standards_Amemdments.pdf
2. Ensure vertical clearance of 25', as well as a 40X14' clear area in front of the waste enclosure (TSM 8-01)
3. Ensure connection of new buildings to existing pedestrian circulation path.
4. Ensure drainage northwest of proposed 2-story addition is maintained.


Scott Haseman
scott.haseman@tucsonaz.gov
Site Landscape REVIEW COMPLETED CDRC TRANSMITTAL

PROJECT: AGM CONTAINER CONTROLS EXPANSION
ACTIVITY NO. TP-PRE-1122-00064
ADDRESS/PARCEL: 3544 E FORT LOWELL RD/111-05-063G
ZONING: P-1

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.

The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to assure compliance with the applicable UDC development criteria and Technical Standards.

COMMENTS:
1. Maximize rainwater harvesting into existing landscape areas to accommodate first flush retention as defined in UDC Section 7.6.6, Use of Water, and as described in the Technical Standards Manual 5.01-5.11.

If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov or 520-837-4988
Site Zoning REVIEW COMPLETED CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review
FROM: Georgia Pennington, Planner

PROJECT: TP-PRE-1222-00064
Parcel(s): 111-05-063G
Current Zoning: P-I
Existing Use: Research and Product Development
Proposed Use: Research and Product Development


TRANSMITTAL DATE: 01/19/22

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 – Development Package. The Development Package is a separate submittal from the building permits, and the building permits cannot be approved until the Development Package is approved.

2. The existing zone is P-I. Research and Product Development are permitted uses in the P-I zone, subject to use-specific standards 4.9.5.C.5, .6, & .8, and 4.9.13.Q. Precision Manufacturing is a permitted use in the P-I zone, subject to use-specific standards 4.9.5.C.2, .4, .5, .6, .8, and 4.9.13.Q.

3. Clarify the land use per Section 11.

4. Maximum Height: 50 Feet

5. Parcels 111-05-063K and Parcel 111-05-063G must be combined prior to Development Package submittal (as it appears construction of a covered walkway crosses the parcel line).

6. Setbacks:
a. Front Street: 21 feet or height of proposed exterior building wall as measured from the back of existing curb or future curb location
b. Side Street: 21 feet or height of proposed exterior building wall as measured from the outside edge of the nearest adjacent travel lane
c. Side: 0’
d. Rear: 1.5 Height of proposed exterior building wall to the property line

7. Motor Vehicle Space requirements:
a. 1 space/300 SF GFA (Product and Research Development)
b. 1 space/1,000 SF GFA(Precision Manufacturing)

8. Bicycle Parking Requirements:
a. Short term: 2 spaces; Long term: 1 space/12,000 SF GFA (min 2) (Product and Research Development)
b. Short term: None; Long term: 1 Space per 15,000 SF GFA (min 2) (Precision Manufacturing)

9. Electric Vehicle Charging Requirements:
a. EV Ready- 5% outlets, EV Capable- 15% (Product and Research Development)
b. None (Precision Manufacturing)

10. Parking Area Access Lanes (PAAL) shall be 24 feet wide for 2-way traffic and fire access.
11. If expansion is 25%, the entire site must meet standards in:
a. Section 7.4 for motor vehicle parking
b. Section 7.5 for loading if applicable
c. Section 7-01 for pedestrian circulation

12. Comply with Section 7-01 Pedestrian Access in the Technical Standards Manual for new construction.

13. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions, please contact me at Georgia.Pennington@tucsonaz.gov.
Traffic Engineering Review REVIEW COMPLETED TP-PRE-1222-00064
3544 E. Ft. Lowell Rd.

Comments:
1. Any existing curb, sidewalk or curb access ramps that are non-compliant will be reconstructed to meet current standards.
2. Provide Sight Visibility Triangles when DP is submitted.
3. For additional information contact an inspector for an onsite precon. 520-791-5100


David Stiffey
DTM Project Coordinator
David.Stiffey@tucsonaz.gov
TW Hydraulic Modeling Review REVIEW COMPLETED 1. Tucson Water has no objections, or to comments on, the proposed development at this time.
2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov