Review Date Reviewer's Name Type of Review Description Status Comments
Fire New Construction REVIEW COMPLETED -New OL will exceed 99 which will require installation of fire sprinklers per IFC 903.2.1.2
-New operational permit from TFD will need to be obtained at final for "places of assembly"
-Fire protection systems are deferred submittals through TFD and required separate permits. This includes fire sprinklers, fire sprinkler monitoring, fire service underground.
john.vincent@tucsonaz.gov
5203495581
Site Engineering REVIEW COMPLETED No comments.

For any questions, please contact
Lianne Evans
lianne.evans@tucsonaz.gov
Site Landscape REVIEW COMPLETED CDRC TRANSMITTAL
PROJECT: BIANCHI'S ITALIAN
ACTIVITY NO. TP-PRE-1222-00044
ADDRESS/PARCEL: 1110 N SILVERBELL RD/115-21-017G
ZONING: C-1

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.

The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to assure compliance with the applicable UDC development criteria and Technical Standards

COMMENTS:
1. Landscape/NPPO has no concerns with this primarily interior remodel of the existing site.

If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov or 520-837-4988
Site Zoning REVIEW COMPLETED CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review
FROM: Paul Camarena, Planner
PROJECT: Thursday Pre-submittal meeting – TP-PRE-1222-00044
Address: 1110 N SILVERBELL RD
Parcel(s): 11521017G
Zoning: C-1
Existing Use: Food service
Proposed Use: Existing
TRANSMITTAL DATE: 12/22/2022

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The use is Food Service, which is permitted in the C-1 zone. The development is subject to use specific standards C-1: 4.9.4.M.1 & 5 and 4.9.13.O
3. If an expansion is less than 25% or if a series of expansions cumulatively results in less than a 25% expansion in, the requirements apply only to the proposed expansion.
4. Vehicular parking requirements are 1 space per 100 sq. ft. GFA and outdoor seating areas
5. Bicycle Parking requirements - Short-term parking 1 space per 2,000 sq. ft. GFA. Minimum requirement is 2 spaces, Long- term parking 1 space per 12,000 sq. ft. GFA, the minimum requirement is 2 spaces.
6. The required setback along speedway and Silverbell Rd is the greater of 21ft or the Height measured from the back of existing curb or future curb location.
7. Ensure access standards found in section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met. Pedestrian access along the street is required. Show complete pedestrian circulation for the site.
8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.
If you have any questions, please contact me at Paul.Camarena@tucsonaz.gov
Traffic Engineering Review REVIEW COMPLETED No Comments
TW Hydraulic Modeling Review REVIEW COMPLETED 1. Tucson Water has no comments on, or objections to, the proposed development.
2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer