Review Date Reviewer's Name Type of Review Description Status Comments
Fire New Construction REVIEW COMPLETED TP-PRE-1123-00386 • Pre-Application Conference Review v1 •1440 S CRAYCROFT RD TUCSON, AZ 85711:
Based on the information provided, TFD has no comments at this time.
Questions: patricia.shelton@tucsonaz.gov / 520.837.7082
Site Engineering REVIEW COMPLETED Tucson codes and ordinances can be found online at https://codelibrary.amlegal.com/codes/tucson/latest/overview
The Design Standards for Stormwater Detention and Retention manual can be found online at https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf

1. Provide adequate area in front of gate for someone without gate access to maneuver and turn around without needing to back into the right of way. Vehicles cannot back out into the MS&R per Tucson Code 25-16.2

Lianne Evans
lianne.evans@tucsonaz.gov
Site Landscape REVIEW COMPLETED This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.

The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to assure compliance with the applicable UDC development criteria and Technical Standards.

Landscape/NPPO has no concerns or questions about the proposed changes to the
proposed project area.

If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov
Site Zoning REVIEW COMPLETED CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review
FROM: Georgia Pennington, Planner
PROJECT: Thursday Pre-submittal meeting – TP-PRE-1123-00386

Address: 1440 S Craycroft Rd
Parcel(s): 131-01-014J/131-01-014H
Zoning: C-1/C-2
Existing Use: Multifamily
Proposed Use: Multifamily
TRANSMITTAL DATE: DECEMBER 12, 2023

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 – Development Package. The Development Package is a separate submittal from the building permits, and the building permits cannot be approved until the Development Package is approved.

2. The existing zone is C-1/C-2. Multifamily Development is a permitted use in the C-1/C-2 zones.

3. The maximum height of a wall or fence within a perimeter yard shall be six feet; however, the wall or fence may be higher than six feet, but no higher than ten feet, if: (See Figure 6.6.1-A, Height of Wall or Fence within a Side or Rear Perimeter Yard .)
a. At least 75% of the area above six feet in height is left unobstructed and open through the use of architectural elements, such as arches, columns, or wrought iron;
b. Part of, or located on top of, a retaining wall no higher than ten feet measured from design grade and no higher than six feet measured from the top of the retaining portion of the wall;
c. A greater height is required through the rezoning process or the special exception land use process; or,
d. A greater height is required by a specific UDC standard.

4. Comply with Section 7-01 Pedestrian Access in the Technical Standards Manual for new construction.

5. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions, please contact me at Georgia.Pennington@tucsonaz.gov.
Traffic Engineering Review REVIEW COMPLETED TP-PRE-1123-00386
1440 S. Craycroft Rd.

Comments:
1. Keynote No. 2 Also add the length of the depth of the ingress/ egress drive, from the gutter line of Craycroft to the sliding gate; at both entrances.
2. Show on the plan, both the existing and future Right of Way.
3. Keynote No. 9 Of which where the pedestrian access sidewalk connects to the sidewalk in the ROW, there will need to be an ADA Landing. The landing shall be 5’ X 5’ and not exceed 2% in all directions.

David Stiffey
DTM Project Coordinator
David.Stiffey@tucsonaz.gov
TW New Area Development REVIEW COMPLETED TP-PRE-1123-00386 - Pre-Application Conference Review v1 – 1440 S CRAYCROFT RD

Tucson Water has no objections to, or comments on, the proposed development.

The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov