Plan Review Detail
Review Status: In Review
Review Details: PRE-APPLICATION CONFERENCE RESIDENTIAL v.1
Plan Number - TP-PRE-1026-00223
Review Name: PRE-APPLICATION CONFERENCE RESIDENTIAL v.1
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Residential Zoning * | PENDING ASSIGNMENT | ||||
| ROW Engineering Review * | PENDING ASSIGNMENT | ||||
| Residential Building * | REVIEW COMPLETED | Based on what is being presented, Building Safety has no concerns or questions about this project. If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov |
|||
| Residential Engineering * | REVIEW COMPLETED | Permit Activity Number: TP-PRE-1026-00223 Project: Land Division - Split a lot Location: 2701 N NORDIC LN Review Date: 11/19/2026 Reviewer: Marco Contreras & Joe Macualay *This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code.* City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf Site Engineering Review Comments: 1. It will be required that the proposed land division be completed through the Minor Subdivision platting process [UDC 8.4.3] 2. The property located at 2701 N NORDIC LN – APN: 111-08-0430 does not qualify as a property that can be split through a “Simple Lot Split” application a. Justification: The property appears to have originally been a part of a previously platted single parcel paired with the associated southern parcel 111-08-0430. As such, this means that the originally platted parcel has already been split into two pieces. For this application to be completed would create three pieces of an original single piece of property. As such, further land division triggers the definition of a subdivision. b. Subdivision - Any property whose boundaries are fixed by a recorded plat, which is divided into three or more lots, tracts, or parcels of land; c. [UDC 8.3.1.E.1] For a property to qualify for a simple “Land Split” application – it is required that it does not constitute a subdivision as defined in Section 11.4.20 which would require compliance with platting requirements of Section 8.4; 3. As the property does not qualify for further land division through a land split application, and a new application be started through TDC Online. It will be required that a Subdivision (Minor Subdivision) application be submitted in compliance with UDC 8.4.3. 4. The Minor Subdivision final plat will be subject to formatting requirements established by Administrative Manual 2-07.0.0 *** Please note: this review is for Pre-Application purposes. Please be aware that additional comments may be forthcoming during formal review process. If you have any questions or concerns, please contact marco.contreras@tucsonaz.gov |
|||
| TW New Area Development * | REVIEW COMPLETED | Based on the information provided, Tucson Water has no objections to the proposed division of the existing parcel into two separate lots. An existing 5/8-inch water meter, located near the northeast corner of 2701 N. Nordic Lane, currently serves the property. The meter is connected to an existing 3/4-inch water service, which in turn connects to the existing 4-inch PVC water main located along the east side of the property within the N. Nordic Lane right-of-way. The proposed lot division and anticipated development of the western portion of the property will require the installation of a new water service with a minimum diameter of 1 inch, along with a new water meter. A potential tapping location is the existing 6-inch PVC Zone B water main within E. Bermuda Street right-of-way. An existing fire hydrant is located at the intersection of N. Nordic Lane and E. Bermuda Street. The water pressure in the 6-inch PVC water main within E. Bermuda Street ranges from 69.79 to 76.79 PSI at an approximate elevation of 2,600 feet and may fluctuate by an additional ±5 PSI. Individual pressure-reducing regulators may be required as part of the private plumbing system to accommodate the available water pressure. For all new domestic water, irrigation water, or fire water service requests, please contact Tucson Water's New Services Section at 520-791-5164 or via email at TW_Common@tucsonaz.gov. The above comments are based on the limited preliminary information provided by the applicant and should not be interpreted as a comprehensive review of the proposed development. Any questions, comments, or concerns regarding these comments may be directed to Deepesh Dawadi, P.E., Engineering Manager, at Deepeshraj.Dawadi@tucsonaz.gov |