| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Residential Building * | REVIEW COMPLETED | Based on the information provided, Building Safety has no concerns or comments at this time. If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov |
|||
| Residential Engineering * | REVIEW COMPLETED | Permit Activity Number: TP-PRE-1026-00218 Project: Lot Line Modification Location: 1520 W RIVERVIEW BL; (115170450 & 115170440) Review Date: 11/12/2026 Reviewer: Dylan Molina - Engineering Associate I - Site Engineering *This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code.* City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Site Engineering Review Comments: 1. Lot Line adjustment application – Lot line adjustment to be completed through a “Lot Split” application through TDC Online. 2. Provide new legal descriptions for each individual parcel being created through this land split application completed by a registered land surveyor. Each description must be a stand-alone file for recording purposes. 3. Provide connection to exterior accessible route through parking lot, rather than in front of parking spaces. Connectivity will be maintained and Inclusive Home Design Ordinance adhered to. 4. Environmental Services will service 4 new dwellings; how will the 8 APC’s be collected and stored? Show APC storage and collection locations on site plans when submitting individual building permits. *** Please note: this review is for Pre-Application purposes. Please be aware that additional comments may be forthcoming during formal review process. If you have any questions or concerns, please contact Dylan Molina; Dylan.Molina@tucsonaz.gov |
|||
| Residential Zoning * | REVIEW COMPLETED | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Jeffrey Cassidy; Planner I PROJECT: TP-PRE-1026-00218 Address: 1516 and 1520 N Riverview Bl, Tucson, AZ 85745 Parcel(s): 115-17-076C and 115-17-0750 Zoning: R-2 Existing Use: Residential – Single Family, Detached Proposed Use: Residential - Middle Housing TRANSMITTAL DATE: November 12, 2026 ZONING COMMENTS: 1. The site is zoned R-2. The proposed use is Residential Use Group – Middle Housing, which is permitted, subject to use specific standards UDC 4.9.7.B.6, .8, & .9. a. Additionally, refer to UDC 4.9.7.B.11 thru 13. 2. To further facilitate Middle Housing development, and in the spirit of cooperation between PDSD and Tucson Water, “Flag Pole Lot” as referenced in Tucson Water Remote Meter Policy (IV-B.08) is hereby reduced from 15’ to 10’ for Middle Housing Development. This policy will be monitored and may be revoked at any time as the new middle housing regulations have recently been adopted and novel in application. Additionally, new codes and other policies are currently being developed that may require modification or revocation of this policy. Therefore, reducing the currently depicted 15’ easement access down to 10’ will negate the need to pursue a Design Development Option (DDO) review for the 3’ dimension currently depicted east of the existing residence on parcel 115-17-0440 as long as a minimum 5’ setback is described moving forward. 3. Dimensional Standards for R-2: a. Maximum lot coverage: 70% b. Maximum height: 25’ c. Perimeter yard (setbacks): 1) North (adjacent to R-2 Zone): 5’ 2) South (adjacent to R-2 Zone): 5’ 3) East (adjacent to R-2 Zone): 5’ 4) West (adjacent to R-2 Zone): 20’ 4. Development Standards a. Parking ratios (UDC 7.4.4-1). Ensure compliance with UDC 7.4.6, Design Standards. 1) Residential Use – Single Family Residential, 2-4 units 1 space per dwelling unit 5. Ensure pedestrian circulation is accessible, a minimum of 4’-0” wide connecting all areas of development and to any street frontage (TSM 7-01). FOR REFERENCE: UDC (Unified Development Code): https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-16 AM (Administrative Manual): https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-8283 TSM (Technical Standards Manual): https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-10261 If you have any questions, please contact me at jeffrey.cassidy@tucsonaz.gov. |
|||
| ROW Engineering Review * | REVIEW COMPLETED | Driveway will be required to be constructed per COT SD 206. Riverview Blvd is under Pavement moratorium until 01/06/2028, Utility connections that require pavement cuts will need to follow public utility administrative manual. |
|||
| TW New Area Development * | REVIEW COMPLETED | Lot#1-1516 W Riverview Blvd To meet Tucson Water’s frontage requirements and accommodate individual meter connections, Lot#1-1516 W Riverview Blvd will require a 10-foot-wide flagpole, which extends the parcel to the right-of-way of W Riverview Blvd to front the existing 6-inch cement asbestos A Zone water main and provide water service to this parcel. Lot#2-1520 W Riverview Blvd There is an existing 5/8-inch water meter serving the lot. The meter is connected to an existing 6-inch cement asbestos A Zone water main located along the south side of the parcel within the right-of-way of W Riverview Blvd. Water pressure in this area is 77-84 PSI at an elevation of 2315ft. Water pressure can vary by an additional 5 psi +/-. This project may require individual pressure regulators as part of private plumbing. Please coordinate with the City of Tucson Department of Transportation and Mobility (DTM) to confirm the paving schedule and whether the proposed work will be subject to the City’s 5-year pavement cut moratorium. If any new domestic water, irrigation water, or fire water services are needed to serve this proposed development, please contact Tucson Water’s New Services Section by calling 520-791-5164 or by sending an email to TW_Common@tucsonaz.gov. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to Deepesh Dawadi (Engineering Manager) at Deepeshraj.Dawadi@tucsonaz.gov. |