Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: TP-PRE-1024-00237
Parcel: 13505149Z

Address:
2401 S WILMOT RD

Review Status: Approved

Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1

Plan Number - TP-PRE-1024-00237
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
Fire New Construction REVIEW COMPLETED TP-PRE-1024-00237 • Pre-Application Conference Review v1 • 2401 S WILMOT RD TUCSON, AZ 85711:
Based on the information provided, TFD has the following comments:
1. Provide Knox access at gates. IFC 24, 503.6, 506.1
2. Provide backflow prevention for underground fire line. IFC 24, 903.3.5
Questions: patricia.shelton@tucsonaz.gov / 520.837.7082
ROW Engineering Review REVIEW COMPLETED Existing Driveways will need to be replaced to meet code. Pedestrian pathway should not exceed 2% cross slope. Max driveway width is 30'.
Traffic Engineering recommends Right In only for middle driveway and Right out for North driveway.
The driveway to the South should be closed per access management guidelines, 2 driveways max per 300' on arterials.
Site Engineering REVIEW COMPLETED TP-PRE-1024-00237
2401 S WILMOT RD

Site engineering comments for this project are as follows:
1. Because the area of disturbance for this site is greater than 1 acre, a Stormwater Pollution Prevention Plan is required. See https://azdeq.gov/what-swppp for more information.
2. The 14ft x 40ft operational clear space in front of the waste enclosures does not include the apron. Please revise the clear space depiction and include waste stream calculations per TSM 8.
3. Clarify the proposed surfacing around the new building. Disturbed areas require groundcover or landscaping used as dust control. See UDC 7.6.4E
4. Show locations of roof downspouts. Stormwater from roof drains may not pass over ADA sidewalks per TSM 7-01.4.3E.
5. Note 25 says New CMU Wall but no wall is indicated on the plans. Please clarify.
6. Pedestrian circulation is required to connect all buildings, dumpster areas, and the sidewalk on the street frontage per TSM 7-01.3.3. Show a continuous pedestrian path to the dumpster area.
7. Please show curb cuts or flush curbs on the plans where inlets to the retention basins are proposed.

Ryan Insalaco
Email: ryan.insalaco@tucsonaz.gov
Phone: (520) 837-5351
Site Landscape REVIEW COMPLETED CDRC TRANSMITTAL
PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
REVIEWER: CHAD KELLER, RLA
PDSD LANDSCAPE/NATIVE PLANT PRESERVATION SECTION

PROJECT: DEMOLISH EXISTING BUILDING AND CONSTRUCT NEW BUILDING ALONG WITH ASSOCIATED PARKING AND SITE WORK
ACTIVITY NO: TP-PRE-1024-00237
ADDRESS: 2401 S WILMOT RD
ZONING: C-2 COMMERCIAL ZONE
LAND USE: COMMERCIAL BUILDING AND PARKING AREA

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting.

The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to ensure compliance with the applicable UDC development criteria and Technical Standards.

SITE LANDSCAPE/NPPO COMMENTS:

1. A landscape plan is required per UDC 7.6.2.B.1-b. The Unified Development Code requires all new development, or an expansion of greater than 25% of an existing development to submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4 and Administrative Manual 2-10.

2. Provide the required number of trees in all vehicular parking areas (1 tree to 4 parking spaces) per UDC 7.6.4.B.1. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a.

3. A street landscape border is required along W Wilmot Rd per UDC 7.6.4.C-2 and Table 7.6.4-1. See UDC 7.6.4.C for landscape border requirements.

4. DTM approval is required for all planting and irrigation in the ROW prior to the approval of the development package. Reach out to David Marhefka (david.marhefka@tucsonaz.gov) if necessary for this project.

5. All landscape plans shall incorporate water conserving design as defined in UDC Section 7.6.6, Use of Water, and as described in the Technical Standards Manual 5.01-5.11.

6. A Commercial Rainwater Harvesting plan is required: See Technical Standards Manual 4-01.3.0 RAINWATER HARVESTING PLAN. A Rainwater Harvesting Plan shall be submitted with all applications for commercial developments at which landscaping is required. The Rainwater Harvesting Plan shall consist of two elements: A Site Water Budget Calculation Spreadsheet and a Water Harvesting Implementation Plan. Preparation of the Rainwater Harvesting Plan elements require coordination between project managers, site engineers and landscape architects from the inception of the project. The two elements of the Rainwater Harvesting Plan shall illustrate how water harvesting will meet 50% of annual landscape water demand, as required by the ordinance. If a copy of the Site Water Budget Spreadsheet is needed, please reach out to the contact information at the bottom of these comments.

7. Ensure that the Landscape Plan, the Commercial Rainwater Harvesting Plan and the Civil Grading Plans are coordinated to show identical basin size, grades, spot elevations and curb cut locations.

8. Maximize rainwater harvesting across the site into all landscape areas, including the street landscape borders and planting islands for the required trees in the parking area.

9. A separate irrigation water meter is required. Please label irrigation meter as “irrigation only”. See TSM 4-01.6.0

If you have any questions about these comments, I can be reached at chad.keller@tucsonaz.gov
Site Zoning REVIEW COMPLETED CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review
FROM: Georgia Pennington; Planner

Address: 2401 S Wilmot Rd
Parcel(s): 135-05-149Z
Zoning: C-2
Existing Use: Elementary and Secondary Educational Use
Proposed Use: Elementary and Secondary Educational Use
TRANSMITTAL DATE: 10/30/2024

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 – Development Package. The Development Package is a separate submittal from the building permits, and the building permits cannot be approved until the Development Package is approved.

2. ADA standards such as sidewalks and parking spaces must be complied with.



3. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions. please contact me at georgia.pennington@tucsonaz.gov
TW New Area Development REVIEW COMPLETED TP-PRE-1024-00237 - Pre-Application Conference Review v1 – 2401 S WILMOT RD

Tucson Water has no objections to the proposed development and offers the following comments for your convenience:

1. The subject parcel is currently being served by a 1 inch water meter that does not appear to be displayed on the proposal. The proposed irrigation and domestic water meters appear to be in a different location.

2. The required domestic water meter size for the proposed high school will be determined by a water fixture count conducted in accordance with the 2018 International Plumbing Code and Tucson Water’s Water Meter Sizing Guidelines. Tucson Water’s Water Meter Sizing Guidelines are available at https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/tucson-water/documents/signed_meter_sizing_guidelines_march_2020.pdf

3. The existing 4” cement asbestos water main in the public alley may not be able to supply the automatic sprinkler system demand (including hose stream allowance) as well as the irrigation and domestic water demands. Hydraulic modeling of these demands will need to be performed to verify Tucson Water’s existing distribution system can supply these demands without creating any adverse conditions anywhere in the distribution system. Please submit a Water Feasibility Study Water Master Plan for this project via the Tucson Development Center Online portal to Tucson Water for review at the earliest opportunity.

4. If you are planning on using the existing 4 inch fire service installed in 1959 per FN 1149, please be aware it will need to be brought up to Tucson Water standards. See Tucson Water Standard Detail SD-500 sheet 4 of 8

5. Please contact Tucson Water’s New Services Section with any questions you may have about obtaining the new domestic water, irrigation water, or fire water services needed to serve this proposed development. Tucson Water’s New Services Section can be reached by calling 520-791-5164 or by sending an e-mail to TW_Common@tucsonaz.gov

The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Michael Asbury, Engineering Associate
Tucson Water, New Development Section
201 N. Stone Avenue, #2 Flr.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2202
michael.asbury@tucsonaz.gov