Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Plan Number: TP-PRE-1023-00359
Parcel: 127090180

Review Status: Approved

Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1

Plan Number - TP-PRE-1023-00359
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
Fire New Construction REVIEW COMPLETED TP-PRE-1023-00359 • Pre-Application Conference Review v1 • 6105 E BROADWAY BL TUCSON, AZ 85711: Based on the information provided, TFD has no comments at this time.
Questions: patricia.shelton@tucsonaz.gov / 520.837.7082
Site Engineering REVIEW COMPLETED 1. Parcel is in a recently mapped Pima County floodplain, a hydrology study will be required to address the flooding potential.
2. Capacity for recycling is required in your refuse enclosure. A double enclosure or multiple single enclosures required.
3. Ensure that all sidewalks provide a minimum of 4 feet of unimpeded width.
4. Maximize water harvesting into all landscaped areas.
Joshua Garcia
joshua.garcia@tucsonaz.gov
Site Landscape REVIEW COMPLETED This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.
The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to assure compliance with the applicable UDC development criteria and Technical Standards.


Comments:
1. Landscape/NPPO has no questions or concerns about the proposed new footprint on the existing site.

If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov
Site Zoning REVIEW COMPLETED CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review
FROM: Paul Camarena, Planner
PROJECT: Thursday Pre-submittal meeting – TP-PRE-1023-00359
Address: 6105 E BROADWAY BL
Parcel(s): 127090180
Zoning: C-1
Existing Use: Food Service
Proposed Use: Food Service
TRANSMITTAL DATE: November 1, 2023

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The use is, Food Service which is permitted in the C-1 zone. The development is subject to use specific standards C-1: 4.9.4.M.1 & 5 and 4.9.13.O
3. Vehicular parking requirements are 1 space per 100 sq. ft. GFA and outdoor seating areas.
For a shopping center the parking requirement is 1 space per 300 sq. ft. GFA

4. Bicycle Parking requirements for short term parking spaces is 1 space per 2,000 sq ft. GFA minimum required is 2 spaces and long term spaces required is 1 space per 12,000 sq ft. GFA minimum required is 2 spaces.
5. The minimum width of a two-way PAAL is 24 ft.
6. Ensure access standards found in section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met. Pedestrian access along the street is required. Show complete pedestrian circulation for the site.
7. As Broadway Bl is designated as an Arterial on the COT MS&R Map the street perimeter yard setbacks are based on Unified Development Code (UDC) Article 6.4.5.C.2.a, For nonresidential and multifamily development abutting an Arterial or Collector Street the minimum required street perimeter yard is ten feet, as measured from the existing or future property line as determined by the adopted Major Streets and Routes Plan , whichever is greater, The interior setbacks are 0 for nonresidential use adjacent to a Nonresidential zone.
8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.
If you have any questions, please contact me at Paul.Camarena@tucsonaz.gov
Traffic Engineering Review REVIEW COMPLETED No Comments

David Stiffey

David.Stiffey@tucsonaz.gov
TW New Area Development REVIEW COMPLETED TP-PRE-1023-00359 - Pre-Application Conference Review v1 – 6105 E BROADWAY BL

Tucson Water has no objections to, or comments on, the proposed development.

The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov