| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Fire New Construction * | REVIEW COMPLETED | TP-PRE-0925-00183 • Pre-Application Conference Review v1 • 5845 S PARK AV TUCSON, AZ 85706: Based on the information provided TFD has the following comments: 1. Verify hydrant coverage. IFC 24, 507.5. Buildings designated as R-2 will require fire sprinklers in accordance with IFC 24, 903.3 Questions: patricia.shelton@tucsonaz.gov / 520.837.7082 |
|||
| ROW Engineering Review * | REVIEW COMPLETED | 1. Reference PAG Standard Details for proposed improvements within the public ROW. 2. Curb and sidewalk required along the property frontage of Alvord Rd. 3. Curb return radius for new driveway on Park Ave should be per Street Design Guide. 4. Only one sidewalk in the ROW is required along Park Ave. If you have any questions, please contact Jesus.Villezcas@tucsonaz.gov |
|||
| Site Engineering * | REVIEW COMPLETED | Permit: TP-PRE-0925-00183 Location: 5845 S PARK AV Review Date: 9/25/2025 Site Engineering Comments: 1. A drainage report will be required to show compliance with First Flush Retention/balanced basin detention will be required for this development, A drainage report will be required to show compliance with Design Standards for Stormwater Detention and Retention Manual Chapters 2, 3, and 4. 2. A geotechnical report will be required to provide setback requirements for all structures in relation to basin proposed and potential issues relating to percolation due to the type C soils found for the site. 3. A grading permit will be required with cut/fill quantities and acres of disturbance 4. A Stormwater pollution prevention plan will be required. 5. The use of Low Impact Development Design practices is encouraged. These methods can be found within the DSSDR chapter 5. 6. Pedestrian Circulation will be required to connect to Alvord RD TSM 7-01.0.0 7. Clarify keynote 23 on the pre-submittal plan. The floor of the basin is required to be pervious to prevent ponding. 8. This review is for Pre-Application purposes. Please be aware that additional comments may be forthcoming during submission process. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
|||
| Site Landscape * | REVIEW COMPLETED | CDRC TRANSMITTAL PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, RLA SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: PROPOSED SITE DEVELOPMENT AT 5845 S. PARK AVENUE ACTIVITY NO: TP-PRE-0925-00183 ADDRESS: 5845 S PARK AV ZONING: O-3 OFFICE ZONE LAND USE: MULTIFAMILY COMMERCIAL This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by the Site Landscape and NPPO section to ensure compliance with the applicable UDC development criteria and Technical Standards. SITE LANDSCAPE/NPPO COMMENTS: 1. A NPPO or a NPPO Waiver is required per UDC 7.7. SEE UDC 7.7.3. APPLICABILITY; UDC 7.7.4 NPPO GENERAL PROVISIONS AND STANDARDS; UDC 7.7.4.C. PLAN APPROVAL PRIOR TO PERMITTING; UDC 7.7.4.D. PROFESSIONAL EXPERTISE 7.7.5.C.5; ALSO SEE AM 2-11.3.0 PERMITTED EXCEPTIONS. PDSD will provide the applicant with the NPPO Waiver form upon request. NOTE: IF COMPLETING THE NPPO WAIVER WITH THE OWNER SIGNING OFF ON THE SITE, THEN PROVIDED PHOTOS ON-SITE AND A RECENT AERIAL THAT CLEARLY SHOWS THAT THERE ARE NO PROTECTED NATIVE PLANT ON SITE. IF ALL OF THIS INFORMATION IS NOT INCLUDED WITH THE WAIVER, THEN SEE COMMENT NUMBER TWO BELOW FOR PROFESSIONAL EXPERTISE AND WHO SHALL COMPLETE THE WAIVER. 2. See UDC 7.7.4.D. Professional Expertise: Preparation of all elements of the Native Plant Preservation Plan and on-site monitoring as required under Section 7.7.5.C.5, On- Site Monitoring, must be performed by a plant professional, such as: 1. An arborist certified by the International Society of Arboriculture; 2. A landscape architect; or, 3. A horticulturist, biologist, or botanist with a minimum B.A. or B.S. in an appropriate arid environment natural resource field. 3. A landscape plan is required. Preparation of the landscape plan shall adhere to UDC 7.6.4 and Administrative Manual 2-10. 4. Provide the required number of trees in all vehicular parking areas (1 tree to 4 parking spaces) per UDC 7.6.4.B.1. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a. 5. An interior landscape borders is required along the east property boundary of the site per UDC 7.6.4.C-2 and Table 7.6.4-1. See UDC 7.6.4.C for landscape border requirements. Multifamily land use adjacent to residence zone requires a 10’ interior landscape border. The south property line with the parking lot adjacent to office zone requires a 5 foot masonry wall. 6. A street landscape border is required along S Park Av and along E Alvord Rd per UDC 7.6.4.C-2 and Table 7.6.4-1. See UDC 7.6.4.C for landscape border requirements. Multifamily land use along MS&R and non-MS&R requires a 10’ street landscape border. 7. A drip irrigation plan and details are required for all proposed landscape planting areas. 8. DTM review is required for all planting and irrigation in the ROW prior to the approval of the development package. Reach out to David Marhefka (david.marhefka@tucsonaz.gov) if necessary for this project. 9. All landscape plans shall incorporate water conserving design as defined in UDC Section 7.6.6, Use of Water, and as described in the Technical Standards Manual 5.01-5.11. 10. A Commercial Rainwater Harvesting plan is required: See Technical Standards Manual 4-01.3.0 RAINWATER HARVESTING PLAN. A Rainwater Harvesting Plan shall be submitted with all applications for commercial developments at which landscaping is required. 11. Coordinate the Landscape Plan, Commercial Rainwater Harvesting Plan and the Civil Grading Plans to have identical basin size, grades/percent slopes, spot elevations and curb cut inlet and outlet locations. 12. Maximize rainwater harvesting across the site into all landscape areas, including the street landscape borders and planting islands for the required trees in the parking area. 13. A separate irrigation water meter is required. Please label irrigation meter as “irrigation only”. See TSM 4-01.6.0 Thank you. Chad Keller, RLA Landscape Architect chad.keller@tucsonaz.gov |
|||
| Site Zoning * | REVIEW COMPLETED | CDRC TRANSMITTAL TO: Planning & Development Services Department FROM: Fernando L. García PDSD Zoning Review Section PROJECT: Multifamily Development 5845 S. Park Av, Tucson AZ 85706 Zoning: O-3 TP-PRE-0925-00183 TRANSMITTAL DATE: September 25, 2025 1. The proposed development must comply with the City of Tucson Unified Development Code (UDC) Administrative Manual Chapter 2-06 – Development Package. Building permits can be submitted and reviewed concurrently with the development package but the building plans cannot be approved until the development package is approved and the building plans are reviewed for consistency. 2. This parcel is zoned O-3. Multifamily development is an allowed use within the O-3. 3. An existing development package (DP), TD-DEV-1123-00470, is currently open on this parcel. Before a new DP can be accepted for this site, the existing DP must be fully withdrawn, including payment of an unpaid fees. 4. This site is bounded by S Park Av on the west side. S Park Av in this area is an arterial road with a proposed width of 120’. It is currently approximately 80’. Ensure provided plans demonstrate the future right-of-way (ROW) and that all required site improvements are outside of the future ROW area. 5. Dimensional standards for a multifamily development within the O-3 zone follow: a. Maximum residential density: 22 dwelling units per acre b. Maximum lot coverage: N/A c. Maximum height: 40’ d. Street perimeter yard: to S Park Av (Arterial): 10’ from future ROW; to E Alvord Rd (Local): 20’. e. Interior perimeter yard: to the west and north (abutting O-3): 10’ or ¾ height of adjacent wall, whichever is greater; to the east (abutting R-2): 10’ or ¾ height of adjacent wall, whichever is greater Perimeter yard measurements were not provided from structures to any adjacent property lines, and as such could not be confirmed, although it appears that required perimeter yard setbacks to the west and east are insufficient based upon the height of the building. Based upon heights of 21’, it is possible that the minimum required setback may reach 15.75’. Less than that appears to be shown on the submitted plans. A Design Development Option (DDO) will be required as a subrecord to the development package in order to request reduction of minimum required setback distances. 6. Minimum required motor vehicle parking requirements are per UDC Table 7.4.4-1. For multifamily development, the number of required spaces is assessed on a per-bedroom basis: a. The number of spaces per dwelling unit is based on the number of bedrooms in each unit as follows: • Studio, less than 400 sq. ft. GFA - 1.00 space per dwelling unit • Studio, more than 400 sq. ft. GFA, and 1 bedroom - 1.50 spaces per dwelling unit • Two bedroom - 2.00 spaces per dwelling unit • Three bedroom - 2.25 spaces per dwelling unit • Four or more bedroom - 2.50 spaces per dwelling unit b. Per the proposed plan, 36 spaces total are required for the 24 one-bedroom units and 8 spaces total are required for the two-bedroom units for a total required 44 spaces. 7. Electric vehicle supply equipment (EVSE) parking is required for this development per UDC Table 7.4.11-1. According to that table, 10% of provided parking spaces must be EV Ready and 20% of provided parking spaces must be EV Capable. If 56 total parking spaces are provided, then 6 of these must be EV Ready and 12 must be EV Ready; none are shown on the plan. 8. Bicycle parking is required per UDC Tabel 7.4.8-1: a. Short-term bicycle parking: 0.10 spaces per bedroom. Minimum requirement is 2 spaces. b. Long-term bicycle parking: 0.5 spaces per bedroom. Minimum requirement is 2 spaces. c. Per the proposed plan (32 bedrooms), three short-term bicycle parking spaces and 16 long-term bicycle parking spaces are required. Long-term bicycle parking can be provided within residential units. 9. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, the Zoning Review Section will conduct a full review to assure compliance with applicable UDC development criteria and technical standards. 10. If you have any questions, please contact me at fernando.garcia2@tucsonaz.gov. |
|||
| TW New Area Development * | REVIEW COMPLETED | TP-PRE-0925-00183 (5845 S PARK AV TUCSON, AZ 85706) Multifamily residential project Based on the information provided, Tucson Water has no objections to, or comments on, the proposed development. Potentially serving this new project is a 12in CA (cement asbestos) potable water main C zone, located on the west side of the lot, ROW of S Park Ave. There is an existing 5/8" water meter currently in place this will not be sufficient for the 29 units proposed. Due to the project size (multi units), this meter must be upgraded to a larger size. The proposed project will incur costs including, but not limited to, "new meter installation", "new service line connection", and "pavement replacement" Please note that there’s significant infrastructure upgrades are currently underway on S Park Ave. The project includes a comprehensive sewage system update followed by a complete repaving of the street to improve long-term functionality and road quality. If any new domestic water, irrigation water, or fire water services are needed to serve this proposed development, please contact Tucson Water’s New Services Section by calling 520-791-5164 or by sending an email to TW_Common@tucsonaz.gov. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Abdullah Salman | Project Manager Tucson Water - New Area Development Abdullah.Salman@tucsonaz.gov |