Plan Number: TP-PRE-0925-00174
Parcel: 113071620

Review Status: Approved

Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1

Plan Number - TP-PRE-0925-00174
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
Fire New Construction * REVIEW COMPLETED TP-PRE-0925-00174 • Pre-Application Conference Review v1 • 1439 E HEDRICK DR TUCSON, AZ 85719:
Based on the information provided TFD has the following comments:
1. Verify dead ends in excess of 150’ are provided with turnarounds. IFC, 2024, D103.4
Questions: patricia.shelton@tucsonaz.gov / 520.837.7082
ROW Engineering Review * REVIEW COMPLETED DTM Comments for Proposed Locations:
As you have noted New Curb, Sidewalk, Driveway, and closure of existing curb opening.
New Sidewalk will need to meet and comply with PAG Standard 200
New Curb will need to meet and comply with PAG Standard 209, 210, 211
New Driveway will need to meet and comply with PAG Standard 206
All non used curb opening will be required to be closed and restore to me standards.
All utility work associate with project within the City of Tucson Right of Way will require separate and individual ROW permits for each scope of work to be performed.
If you have any further questions please feel free to reach me at
Zane Swenson
Engineering Associate
Dept. of Transportation and Mobility | Engineering Division
| Zane.Swenson@Tucsonaz.gov
Site Engineering * REVIEW COMPLETED Permit: TP-PRE-0825-00174
Location: 1439 E HEDRICK DR
Review Date: 9/18/2025
Site Engineering Comments:
1. A Drainage report will be required.
2. Detention within regulated floodplains is not permitted without the approval of the Floodplain Administrator per DSSDR chapter 4.2. Use Low Impact Development Design and water harvesting to provide balanced basin detention and first flush retention. DSSDR Ch 5.
3. An encroachment analysis will be required. Tucson Code Chapter 26 section 26-5.2
4. Flood venting will be required for the new CMU perimeter wall. Have the dimensions and spacing requirements included in the Drainage Report. Tucson Code Chapter 26 Section 26-8.
5. Pedestrian Circulation will be required to connect all buildings, dumpster areas, and the sidewalk on the street frontage per TSM 7-01.3. 3.
6. Sight Visibility triangles will be required for all site entrances/exits. Hedrick is a minor local road. Technical Standards Manual 10-01.5.0
7. Waste stream calculations will be required. Show that both solid waste and recycle collection service are met in accordance with Technical Standards Manual 8-01.4.0.H.
8. To ensure compliance with accessible cross-slope standards, Site Engineering suggests the proposed ramp between the ADA spaces be converted to a depressed curb to landing with two ramps sloping up from there.
9. A grading plan will be required for this development due to the floodplain status. Tucson Code Chapter 26 Section 26-8.a.3
10. Provide a Keynote for hatched square in the northwest corner of the parking lot.
11. This review is for Pre-Application purposes. Please be aware that additional comments may be forthcoming during submission process.

If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
Site Landscape * REVIEW COMPLETED CDRC TRANSMITTAL
PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
REVIEWER: CHAD KELLER, RLA
SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION

PROJECT: MULTI-FAMILY FLD SITE PLAN; FLD WILL USE THE INCREASED OPEN SPACE OPTION
ACTIVITY NO: TP-PRE-0925-00174
ADDRESS: 1439 E HEDRICK DR
ZONING: R-2 RESIDENCE ZONE
LAND USE: FLD, POSSIBLY STANDARD MULTIFAMILY

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting.

The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by the Site Landscape and NPPO section to ensure compliance with the applicable UDC development criteria and Technical Standards.

IF USING THE FLEXIBLE LOT DEVELOPMENT STANDARDS FOR THIS SITE -- LANDSCAPE COMMENTS:

1. UDC 8.7.3.H -- LANDSCAPING, SCREENING AND WALL REQUIREMENTS:
1. FLD projects shall comply with Section 7.6, Landscaping and Screening Standards, except as otherwise provided by this section.
2. One canopy tree shall be provided for every 40 feet of pedestrian circulation systems, excluding crossings with streets, alleys, and driveways. If providing canopy trees every 40 feet is not achievable, the applicant shall:
a. Provide the equivalent number of trees that would be obtained using the 40-foot increment measure; and,
b. Distribute the trees within the FLD project site along pedestrian circulation systems and within functional open space areas.
3. Landscape plans shall incorporate water-conserving design as defined in Section 7.6.6, Use of Water, and as described in the Technical Standards Manual.
4. Water harvesting techniques shall be incorporated as part of the landscape design based on the Water Harvesting Guidance Manual prepared for the City of Tucson Transportation Department Stormwater Section.
5. Mechanical equipment, utility boxes, irrigation equipment and similar elements shall be screened from adjacent streets exterior to the project and from adjacent existing residential development. Screening shall be architecturally integrated with the overall design of the FLD.
6. If a perimeter wall is proposed along an existing public right-of-way, it shall be constructed of, or painted with, graffiti-resistant materials. The wall shall incorporate one or more of the following decorative materials:
a. Tile;
b. Stone;
c. Brick;
d. Adobe;
e. A textured material such as stucco or plaster; or,
f. Metal.

2. UDC 8.7.3.F: OPEN SPACE REQUIREMENTS. See Table 8.7.3-2 for Functional Open Space Standards.

3. (4) ADDITIONAL FUNCTIONAL OPEN SPACE: The project preserves at least 20% more Functional Open Space than is required by Section 8.7.3.F.1, Functional Open Space Requirements. The additional open space shall be usable for passive or active recreational uses, such as trails, walking paths, picnic areas, and playgrounds.

4. On the Development Package landscape plans provide calculations for functional open space and how the plan meets the standards set forth in the previous two comments.

5. UDC 8.7.3.F.2 CONFIGURATION AND LOCATION OF FUNCTIONAL OPEN SPACE WITHIN AN FLD PROJECT ARE AS FOLLOWS:
a. FLD projects five acres and less. Functional open space amenities should be configured as contiguous areas but may also be incorporated into the design of other elements on the site, such as detention/retention basins and buffers, to make those areas functional.
b. FLD projects more than five acres. Functional open space may be divided into smaller areas if they are distributed throughout the project site and conveniently located for residents of the FLD project.
c. Functional open space shall be conveniently located to and usable by the maximum number of residential units on the site.
d. To the greatest extent possible, functional open space should not be comprised of remnant areas that are not usable by residents of the FLD project.
e. Where the project is located near a public preserve or can provide connections to open space areas or areas of environmentally or culturally significant features, the open space shall be configured in a manner to preserve this connectivity.

6. A NPPO OR A NPPO WAIVER IS REQUIRED PER UDC 7.7. SEE UDC 7.7.3. APPLICABILITY; UDC 7.7.4 NPPO GENERAL PROVISIONS AND STANDARDS; UDC 7.7.4.C. PLAN APPROVAL PRIOR TO PERMITTING; UDC 7.7.4.D. PROFESSIONAL EXPERTISE 7.7.5.C.5; ALSO SEE AM 2-11.3.0 PERMITTED EXCEPTIONS. PDSD will provide the applicant with the NPPO Waiver form upon request.

7. UDC 7.6.2. APPLICABILITY: The provisions of this section apply to the following: All new development requires the preparation of landscape plans that adhere to UDC 7.6.4 and Administrative Manual 2-10.

8. Provide the required number of trees in all vehicular parking areas (1 tree to 4 parking spaces) per UDC 7.6.4.B.1. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a.

9. A 10-foot interior landscape border is required along the east and west property lines per UDC 7.6.4.C-2 and Table 7.6.4-1. See UDC 7.6.4.C for landscape border requirements. Site Zoning required building setback from the property line will determine the required width of the interior landscape borders, otherwise the 10-foot border is required.

10. A 10-foot street landscape border is required along E Hendrick Dr per UDC 7.6.4.C-2 and Table 7.6.4-1. See UDC 7.6.4.C for landscape border requirements. A DDO may be required to offset the landscape and tree location in the southwest corner near the trash enclosure. Please reach out to Mark Castro with Current Planning for more information on the process. Mark.Castro@tucsonaz.gov.

11. A drip irrigation plan and details are required for all proposed landscape planting areas.

12. Depress Functional Open Space landscape planting areas 6 inches to maximize rainwater harvesting on site.

13. DTM review is required for all planting and irrigation in the ROW prior to the approval of the development package. Reach out to David Marhefka (david.marhefka@tucsonaz.gov) if necessary for this project.

STANDARD SITE LANDSCAPE/NPPO COMMENTS IF STANDARD MULTIFAMILY DEVELOPMENT STANDARDS NEED TO BE MET:

14. A NPPO OR A NPPO WAIVER IS REQUIRED PER UDC 7.7. SEE UDC 7.7.3. APPLICABILITY; UDC 7.7.4 NPPO GENERAL PROVISIONS AND STANDARDS; UDC 7.7.4.C. PLAN APPROVAL PRIOR TO PERMITTING; UDC 7.7.4.D. PROFESSIONAL EXPERTISE 7.7.5.C.5; ALSO SEE AM 2-11.3.0 PERMITTED EXCEPTIONS. PDSD will provide the applicant with the NPPO Waiver form upon request.

15. UDC 7.6.2. APPLICABILITY: The provisions of this section apply to the following: All new development requires the preparation of landscape plans that adhere to UDC 7.6.4 and Administrative Manual 2-10.

16. Provide the required number of trees in all vehicular parking areas (1 tree to 4 parking spaces) per UDC 7.6.4.B.1. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a.

17. A 10-foot interior landscape border is required along the east and west property lines per UDC 7.6.4.C-2 and Table 7.6.4-1. See UDC 7.6.4.C for landscape border requirements. Site Zoning required building setback from the property line will determine the required width of the interior landscape borders, otherwise the 10-foot border is required.

18. A 10-foot street landscape border is required along E Hendrick Dr per UDC 7.6.4.C-2 and Table 7.6.4-1. See UDC 7.6.4.C for landscape border requirements.

19. A drip irrigation plan and details are required for all proposed landscape planting areas.

20. All landscape plans shall incorporate water conserving design as defined in UDC Section 7.6.6, Use of Water, and as described in the Technical Standards Manual 5.01-5.11.

21. A Commercial Rainwater Harvesting plan is required: See Technical Standards Manual 4-01.3.0 RAINWATER HARVESTING PLAN. A Rainwater Harvesting Plan shall be submitted with all applications for commercial developments at which landscaping is required.

22. Coordinate the Landscape Plan, Commercial Rainwater Harvesting Plan and the Civil Grading Plans to have identical basin size, grades, spot elevations and curb cut locations.

23. Maximize rainwater harvesting across the site into all landscape areas, including the street landscape borders and planting islands for the required trees in the parking area.

24. A separate irrigation water meter is required. Please label irrigation meter as “irrigation only”. See TSM 4-01.6.0

25. DTM review is required for all planting and irrigation in the ROW prior to the approval of the development package. Reach out to David Marhefka (david.marhefka@tucsonaz.gov) if necessary for this project.

Thank you.
Chad Keller, RLA
Landscape Architect
chad.keller@tucsonaz.gov
520.837.4923
Site Zoning * REVIEW COMPLETED CDRC TRANSMITTAL

TO:
Planning & Development Services Department

FROM: Fernando L. García
PDSD Zoning Review Section

PROJECT:
1439 E Hedrick Dr, Tucson, AZ 85719
Parcel(s): 113-07-1620
Zoning: R-2
Pre-Submittal Conference (1st Review)
TP-PRE-0925-00174


TRANSMITTAL DATE: September 17, 2025

1. The proposed development must comply with the City of Tucson Unified Development Code (UDC) Administrative Manual Chapter 2-06 – Development Package. Building permits can be submitted and reviewed concurrently with the development package but the building plans cannot be approved until the development package is approved and the building plans are reviewed for consistency.

2. This site is zoned R-2. Single-family attached or detached, and multifamily residential developments utilizing the FLD provisions of the UDC are permitted in the R-2 zone.

3. The project proposes to utilize the Flexible Lot Development standards as articulated in UDC 8.7.3 under the “Maximum Density Option” indicated in 8.7.3.b. under the option for “Additional Functional Open Space”.

4. Per UDC Table 8.7.3-1, the dimensional standards for an FLD development utilizing the “Maximum Density Option” (Development Alternative B) are:

a. Site coverage maximum: 75%
b. Allowable density maximum: 22.00 dwelling units per acre
c. Building height maximum: 25’

5. Site coverage calculations per UDC Section 6.4.3. were not provided on the site map and cannot be verified.

6. Based upon a lot size of 38,186 sf, using the “Maximum Density Option” on an R-2 lot allows up to 19 dwelling units.

7. The site plan indicates that drainage basins will be used as part of the required “Functional Open Space” area. If so, per UDC 8.7.3.F.1.e, these basins must incorporate Multiple-Use Concepts and Aesthetic Design Guidelines described in Chapter IV of the Stormwater Detention/Retention Manual.

8. The required minimum building setbacks to the east property are 6’ or 2/3 the height of the adjacent building wall, whichever is greater. Provided setbacks along the eastern property line appear to be less than the required 2/3. Provide measurements for wall heights measured from design grade for both the 13’ and 22’ foot wall portions, as well as separate setback measurements for both.

Along the westside, the provided setback of 8.8’ appears to be less than that required for a wall height of 14’ 3” for the one-bedroom units.

A Design Development Option (DDO) will be required to modify any required setback distances. Apply for a DDO by submitting a Zoning Modifications subrecord within the Development Package permit for this project. Reach out to Georgia Pennington for more information about the DDO, including application and process, at georgia.pennington@tucsonaz.gov.

9. This proposal would not require an architectural variation plan.

10. Along the east and westside property lines, where this parcel abuts existing single-family homes (1433 W Hedrick and 1501 W Hedrick), privacy mitigation, as indicated in UDC 8.7.3.M.2.b through a Privacy Mitigation Plan, is required. Balconies, windows (except for clerestory and translucent windows), or any other feature on an upper floor that overlook the rear and side yards of an residence are prohibited.

11. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package/Tentative Plat review process, the Site Zoning Review Section will conduct a full review to assure compliance with applicable UDC development criteria and technical standards.

12. If you have any questions, please contact me at fernando.garcia2@tucsonaz.gov.
TW New Area Development * REVIEW COMPLETED TP-PRE-0925-00174 (1439 E HEDRICK DR TUCSON, AZ 85719)
Multi-Family FLD Site Plan.
Based on the information provided, Tucson Water has no objections to, or comments on, the proposed development.
Potentially serving this newly formed parcel is a 6in CA (cement asbestos) potable water main A zone, located on the south of the lot, ROW of E Hedrick Dr.
There is an existing 5/8" water meter currently in place this will not be sufficient for the 18units proposed. Due to the project size (multi units), this meter must be upgraded to a larger size.
The proposed project will incur costs including, but not limited to, "new meter installation", "new service line connection", and "pavement replacement"
If any new domestic water, irrigation water, or fire water services are needed to serve this proposed development, please contact Tucson Water’s New Services Section by calling 520-791-5164 or by sending an email to TW_Common@tucsonaz.gov.

The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Abdullah Salman | Project Manager
Tucson Water - New Area Development
Abdullah.Salman@tucsonaz.gov