Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: TP-PRE-0924-00222
Parcel: 12416158A

Address:
1050 S PARK AV

Review Status: Approved

Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1

Plan Number - TP-PRE-0924-00222
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
Fire New Construction REVIEW COMPLETED TP-PRE-0924-00222 • Pre-Application Conference Review v1 • 1050 S PARK AV TUCSON, AZ 85719:
Based on the information provided, TFD has the following comments:
Verify that the existing underground fire line is not located below the new addition.
Questions: patricia.shelton@tucsonaz.gov / 520.837.7082
ROW Engineering Review REVIEW COMPLETED TP-PRE-0924-00222 • 1050 S PARK AV

1. The existing parking spaces shown in the Park Av public right-of-way will have to be eliminated. The two parking spaces interfere with the pedestrian circulation path. Additionally, Per Sec. 5.4.5 of the UDC, no portion of the MS&R ROW may be used for complying with UDC Standards.

If you have any questions, please contact Richard Leigh at 520-403-0970 or email richard.leigh@tucsonaz.gov.
Site Engineering REVIEW COMPLETED 1. Ensure parking dimensions comply with UDC 7.4.6.
2. Provide waste stream calculations compliant with TSM Section 8
3. Pedestrian circulation is required to connect all buildings, common use areas, and the sidewalk on the street frontage per TSM 7-01.3.3. Show a continuous pedestrian path that maintains a 4-ft unobstructed width.


Chris Arrington
chris.arrrington@tucsonaz.gov
Site Landscape REVIEW COMPLETED CDRC TRANSMITTAL
PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
REVIEWER: CHAD KELLER, RLA
PDSD LANDSCAPE/NATIVE PLANT PRESERVATION SECTION

PROJECT: NEW BUILDING ADDITION WITH NEW PARKING
ACTIVITY NO: TP-PRE-0924-00222
ADDRESS: 1050 S PARK AV
ZONING: I-1 LIGHT INDUSTRIAL ZONE

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting.

The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to ensure compliance with the applicable UDC development criteria and Technical Standards.

SITE LANDSCAPE/NPPO COMMENTS:

1. Site Landscape has no comments of concerns with this building expansion.

Thank you.
Chad Keller, RLA
chad.keller@tucsonaz.gov
Site Zoning REVIEW COMPLETED CDRC Thursday Pre-Submittal Transmittal
FROM: Nicholas Martell, Principal Planner
PDSD Zoning Review
PROJECT: Pre-submittal meeting TP-PRE-0924-00222
Address: 1050 S PARK AV
Zoning: I-1
Existing Use: Residential Care Service-Rehabilitation Service or Shelter Care
Proposed Use: Residential Care Service- Rehabilitation Service or Shelter Care
TRANSMITTAL DATE: October 9, 2024

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06, Development Package
2. A Commercial – Residential Care Service- Rehabilitation Service or Shelter Care is an allowable use with adherence to use specific standards I-1: 4.9.7.J.1, 3.d, .4, .5, .6, and 4.9.13.Q
a. A board of adjustment variance will be required, as the site appears to not meet the 500 foot separation requirements to a residential zone.
3. Per UDC Table 6.3-5.A, the following dimensional standards apply:
a. Height Maximum: 75’
b. Lot Coverage: N/A
c. Lot Size: N/A
d. 0’ perimeter yard setback requirements adjacent to non-residential zones.
4. Ensure compliance with Table 7.4.4-1: Minimum Number of Motor Vehicle Spaces Required. More information is required, as parking is dependent on the number of residents at the care facility. Parking appears to be sufficient.
5. Per UDC 6.4.5.C.2.b. For nonresidential and multifamily development abutting a Local Street (21st, Park) : the minimum required street perimeter yard is 20 feet, as measured from the street property line .
6. Ensure access for the proposed southern parcel complies with section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual.
a. The pedestrian circulation paths must comply with 7-01.3: Within all development, a continuous pedestrian circulation path is required as follows:
A. This path must connect all public access areas of the development and the pedestrian circulation path located in any adjacent streets.
B. The areas within the development which must be connected include, but are not limited to, all buildings, all bicycle and vehicle parking areas, all recreation areas, all dumpster areas, and all other common use areas.
7. Ensure bike parking, per Table 7.4.8-1 of the UDC is adequate.
a. Short Term Parking Required: 0.05 spaces per bedroom. Minimum requirement is 2 spaces.
b. Long-Term Parking Required: 0.10 spaces per bedroom. Minimum requirement is 2 spaces.
c. Ensure compliance with UDC 7.4.9 – Bike Parking Design Criteria

8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions, please contact me at Nicholas.Martell@tucsonaz.gov.
TW New Area Development REVIEW COMPLETED TP-PRE-0924-00222 - Pre-Application Conference Review v1 – 1050 S PARK AV

Tucson Water has no objections to, or comments on, the proposed development.

The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:


Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov