| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Fire New Construction | REVIEW COMPLETED | TP-PRE-0923-00318 • Pre-Application Conference Review v1 • 3114 N ALVERNON WY TUCSON, AZ 85712: Based on the information provided, TFD has the following comments: 1. Verify hydrants to meet the requirements of 2018 IFC, 507.5.1. 2. Provide turn arounds in accordance with 2018 IFC, D103.4 Questions: patricia.shelton@tucsonaz.gov / 520.837.7082 |
|||
| Site Engineering | REVIEW COMPLETED | Tucson codes and ordinances can be found online at https://codelibrary.amlegal.com/codes/tucson/latest/overview The Design Standards for Stormwater Detention and Retention manual can be found online at https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf 1. The site is located in a regulatory floodplain. All buildings on the site will require floodplain use permits and must be elevated a foot above the base flood elevation. The elevation will require certification through an elevation certificate filled out by a registered land surveyor both prior to the pouring of the foundation and after the completion of construction. 2. An encroachment analysis on the floodplain will be required in the drainage report on the site 3. Balanced basin detention and first flush retention are required on the site. 4. Pedestrian circulation is required to all buildings and the trash enclosure as well as out to the street frontage. 5. There is a future road widening that encroaches into the parcel to the west by around 20 feet. No buildings can be constructed in the future right-of-way. 6. From recent clarification from Environmental Services per TSM section 8, although recycling service isn’t required the site needs to provide at minimum the enclosure space for both solid waste and recycling. A single enclosure won’t be sufficient and a double enclosure or additional single enclosures will be needed to meet this requirement. 7. A waste enclosure will be required for the proposed solid waste collection. Lianne Evans lianne.evans@tucsonaz.gov |
|||
| Site Landscape | REVIEW COMPLETED | CDRC TRANSMITTAL PROJECT: WAREHOUSE DISTRIBUTION CENTER ACTIVITY NO. TP-PRE-0923-00318 ADDRESS/PARCEL: 3114-116 N ALVERNON WY/ 110-05-002A, 110-06-0210 ZONING: MH-1 This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to assure compliance with the applicable UDC development criteria and Technical Standards. COMMENTS: 1. There must be a NPPO. An NPPO is required per UDC 7.7.3-B. A Native Plant Preservation Plan, Section 7.7.4, is required to be submitted or approved or a request for an exception from the Native Plant Preservation requirements approved in accordance with Sections 7.7.3.D.3 & .4 of the UDC and Admin. Manual Section 2-11.0.0 prior to Grading Plan approval. 2. A landscape plan is required per 7.6.2.B.1-b. The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development to submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4 and Administrative Manual 2-10. 3. There will need to be a street landscape border on N Alvernon WY per UDC 7.6.4.C-2 and Table 7.6.4-1. See UDC 7.6.4.C for landscape border requirements. 4. See Engineering notes for Retention/Detention. 5. All landscape plans shall incorporate water conserving design as defined in UDC Section 7.6.6, Use of Water, and as described in the Technical Standards Manual 5.01-5.11. 6. Maximize the rainwater harvesting across the site into the landscape areas, including but not limited to the street landscape borders as well as the tree wells for the required trees for the parking lot. If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov or 520-837-4988 |
|||
| Site Zoning | REVIEW COMPLETED | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Paul Camarena, Planner PROJECT: Thursday Pre-submittal meeting – Address: 3114 N ALVERNON WY Parcel(s): 110060210 Zoning: MH-1/R-3 Existing Use: Vacant Proposed Use: Multifamily TRANSMITTAL DATE: September 20, 2023 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The use is Multifamily Development, which is permitted in the MH-1/R-3 zone. 3. Vehicular parking requirements is based on the number of bedrooms in each unit as follows: • Studio, less than 400 sq. ft. GFA - 1.00 space per dwelling unit • Studio, more than 400 sq. ft. GFA, and 1 Bedroom - 1.50 spaces per dwelling unit • Two Bedrooms - 2.00 spaces per dwelling unit • Three Bedrooms - 2.25 spaces per dwelling unit • Four or More Bedrooms - 2.50 spaces per 4. Bicycle Parking requirements are 0.10 spaces per bedroom. Minimum requirement is 2 spaces for short term parking spaces and 0.5 spaces per bedroom. Minimum requirement is 2 spaces for long term spaces required 5. The density in the MH-1 zone is 8 units per acre, Residential density in multifamily projects developed is calculated in the following manner. Multiply the area of the site , in acreage, by the density (units per acre ratio) permitted by the underlying zoning. 6. Ensure access standards found in section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met. Pedestrian access along the street is required. Show complete pedestrian circulation for the site. 7. The required setback along Alvernon way for nonresidential and multifamily development abutting an Arterial or Collector Street the minimum required street perimeter yard is ten feet, as measured from the existing or future property line as determined by the adopted Major Streets and Routes Plan , whichever is greater. 7A. The interior setback are the greater of 10ft or ¾ the height of the structure. Lot coverage max 70%, maximum height is 25ft. 8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at Paul.Camarena@tucsonaz.gov |
|||
| Traffic Engineering Review | REVIEW COMPLETED | TP-PRE-0923-00318 3114 N. Alvernon Way Comments: 1. The existing curb, sidewalk and driveway apron may remain if it is within tolerance of current standards. 2. Structures, (buildings, walls, posts, signs, parking, etc.) are not allowed to be constructed in the “Future Right of Way,” within 600’ of an intersection in accordance with the MS&R. David Stiffey DTM Project Coordinator David.Stiffey@tucsonaz.gov |
|||
| TW New Area Development | REVIEW COMPLETED | TP-PRE-0923-00318 - Pre-Application Conference Review v1 – 3114 N ALVERNON WY Tucson Water has no objections to the proposed development and offers the following comments for your convenience: 1. There is an existing 8” ductile iron water main Alvernon Way that can serve this development. 2. If these single family dwellings are to be rental units, they may all be connected to a single master water meter. 3. Tucson Water’s records indicate this site is currently served by an existing 1½” water meter connected to the existing 8” water main by a 1½” HDPE water service line. Please contact Tucson Water’s New Services Section by sending them an e-mail at tw common@tucsonaz.gov to see if the existing water meter is large enough to serve the proposed development. They will need to know how many water fixture units will be in your project as calculated using the 2018 International Plumbing Code. 4. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |