Plan Review Detail
Review Status: Approved
Review Details: PRE-APPLICATION CONFERENCE RESIDENTIAL v.1
Plan Number - TP-PRE-0826-00165
Review Name: PRE-APPLICATION CONFERENCE RESIDENTIAL v.1
Review Status: Approved
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Design Review * | REVIEW COMPLETED | It's probable that no NPZ design review will be required for the project. Your building permit submittal should include a north elevation drawing of the entire parcel, with the existing home, vegetation, and the proposed structure drawn to determine visibility. | |||
| Residential Building * | REVIEW COMPLETED | PROJECT: LINDEN TRIPLEX ACTIVITY NO. TP-PRE-0826-00165 ADDRESS: 1728 E LINDEN ST/113-11-2250 If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov Please note: this is a cursory review based on what was submitted to the Pre-Application. COMMENTS: 1. City of Tucson adopted the 2024 IRC on January 1, 2026, and went into effect on January 1, 2026 – please ensure all plans adhere to those standards. 2. City of Tucson adopted the 2024 IECC on January 1, 2026, and went into effect July, 1, 2026 – please ensure that all plans adhere to those standards. 3. Ensure your building design meets all fire rating/fire separation distances. 4. There will be Outdoor Lighting Code Review on this project, please plan and ensure your engineer submits those pages are part of your submittal. https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/2012_outdoor_lighting_code_.pdf 5. Please ensure that all special inspections/deferred submittals (field reports, etc) are understood by the General Contractor who understands the timing of when they are to be approved. City of Tucson *will* withhold final C of O’s until they have been approved. They should be submitted in a timely manner that fits the sequencing of the actual construction process, i.e Post Tension Special Inspection reports should be submitted shortly after they are performed. The day before a C of O is to be sought will not give staff enough time to review these. 6. Ensure you have settled all addressing issues prior to submittal – that is contact Pima County Addressing (https://www.pima.gov/2588/Addressing) and have new addresses for these units prior to your submittal of any and all building permits. 7. Ensure you have begun the process for any and all sewer/wastewater related permits through Pima County prior to the submission of any and all new building permits related to the site. (https://www.pima.gov/1091/RWRD-Sewer-Improvement-Plan-Construction) |
|||
| Residential Zoning * | REVIEW COMPLETED | CITY OF TUCSON, AZ PLANNING AND DEVELOPMENT SERVICES DEPARTMENT (PDSD) TRANSMITTAL ZONING REVIEW Jeffrey William Cassidy jeffrey.cassidy@tucsonaz.gov Commercial Plans Examiner – Current Zoning Section PRE-APPLICATION CONFERENCE / RELATED CASE NUMBER(S): TP-PRE-0826-00165 C9-11-01: Rezoning PRE-APPLICATION CONFERENCE DATE: August 20, 2026 CUSTOMER: Elizalde, Arturo; Arthouse Construction; Bduran762@gmail.com ; (520) 838-1004 PROJECT SCOPE / SUMMARY / DESCRIPTION / NARRATIVE: Proposal for a new triplex residential development. PARCEL(S); ADDRESS; ACREAGE / SQUARE FEET: 113-11-2250; 1728 E Linden St, Tucson, AZ 85719; Approximately 0.25 acres or 10,884 square feet EXISTING USE(S) (Per UDC Article 11 Definition(s)): https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-7039 11.3.7. RESIDENTIAL USE GROUP, A. FAMILY DWELLING, 6. SINGLE-FAMILY DWELLING, DETACHED A dwelling unit that is not attached to any other dwelling unit by any structural elements, surrounded by open space and located on its own separate lot. PROPOSED USE(S) (Per UDC Article 11 Definition(s)): https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-7039 11.3.7. RESIDENTIAL USE GROUP, A. FAMILY DWELLING, 3. MIDDLE HOUSING A building or buildings with two to four dwelling units on a site , including townhomes, excluding Accessory Dwelling Units. PARCEL(S) ZONING: UDC ARTICLE 4: ZONES https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-1785 4.7.8. RESIDENCE ZONE (NR-1) This zone provides for urban, low density, single-family, and middle housing residential development, together with schools, parks, and other public services necessary for a satisfactory urban residential environment. Certain other uses, such as day care and urban agriculture, are permitted that provide reasonable compatibility with adjoining residential uses. PERMITTED USE: Confirmation that Parcel 113-11-2250 lies within the NR-1 zone and the proposed Middle Housing use, as defined under 11.3.7.A.3 is deemed as a permitted use under Table 4.8-2 https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-2077 APPLICABLE USE SPECIFIC STANDARDS: 4.9.7.B.4-.6, .8, .9, .11-.14: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-2638 Of note; 12. Parking for middle housing is required per UDC Table 7.4.4-1. Required parking may be met with on street parking or waived if the site is within a quarter-mile walking distance of an "All Ages and Abilities Bikeway" as defined by the Department of Transportation and Mobility or a public transit route. Parking provided is exempt from Section 7.6.4, Landscape Standards. Front yards are permitted one driveway no more than 20 feet in width and up to 400 square feet of additional vehicular use area. ZONING REVIEW COMMENTS SUMMARY: 1. COMMENT: PRELIMINARY REVIEW The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the permit review process, the Zoning Review Section will conduct a full review to assure compliance with applicable UDC development criteria and technical standards. 2. COMMENT: UDC ARTICLE 6: DIMENSIONAL STANDARDS & MEASUREMENTS DENSITY: 1 single family unit / 6,000 square feet (SF), 4 middle housing units / 6,000 SF LOT SITE / SITE AREA MINIMUM: 6,000 SF LOT COVERAGE: 70% (square footage of enclosed buildings and vehicular use area / Lot SF) MAXIMUM BUILDING HEIGHT: 25’-0” FRONT YARD SETBACK: 20’-0” INTERIOR SIDE YARD SETBACK, RESIDENTIAL USE ADJACENT TO RESIDENTIAL ZONE: 5’-0” Reference Table 6.3-2.A for Dimensional Standards https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-4861 3. COMMENT: UDC ARTICLE 7: DEVELOPMENT STANDARDS https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5321 Per 7.4.4. and Table 7.4.4-1: Required Number of Motor Vehicle Standards https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5445 Principal Existing Residence: One Single Family Residence – 2.25 spaces (2) per 4.9.7.B.7: Triplex: Middle Housing - 1 space per dwelling unit. Per 4.9.7.B.12., Parking for middle housing is required per UDC Table 7.4.4-1. Required parking may be met with on-street parking or waived if the site is within a quarter-mile walking distance of an "All Ages and Abilities Bikeway" as defined by the Department of Transportation and Mobility or a public transit route. Parking provided is exempt from Section 7.6.4, Landscape Standards. Front yards are permitted one driveway no more than 20 feet in width and up to 400 square feet of additional vehicular use area. Landscape Requirements: Reference 7.6.8. New Single Family, Middle Housing, and Accessory Dwelling Units https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-6131 and https://middle-housing-cotgis.hub.arcgis.com/pages/Residential-Landscaping-Code Parking is proposed at south end of the lot implying vehicle access is allowed via the existing ‘N of Lester St E’ alley. This alley does not meet the UDC 7.10.1 standard so the proposed parking will not be an option. Reference 7.10. Alleys https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-6399 4. COMMENT: PEDESTRIAN CIRCULATION Per the City of Tucson Inclusive Home Ordinance 10463: all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway, sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402-404 of the Accessibility Standards. See also TSM 7-01.4.3 for specifications, including the minimum 4ft-width, slope and permissible composition materials. 5. COMMENT: UDC ARTICLE 5: OVERLAY ZONES https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-3088 This parcel falls within the Neighborhood Preservation Zone (NPZ) overlay zone (Rita Rd) and is subject to stipulations as indicated in UDC Sections 5.10. Refer to Design reviewer comments. Reference 5.10. NEIGHBORHOOD PRESERVATION ZONE (NPZ) https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-4383 Zoning has acknowledged this property has a structure on-site with a with ‘contributing status’ with the National Register of Historic Places and advises the owner to contact the State Historic Preservation Office (HPO) to determine if this project will impact the status. Contact https://azstateparks.com/SHPO for more information. This comment is purely made as a courtesy as there may be tax implications. No action is required and is at the discretion of the owner. 6. COMMENT: CONCURRENT REVIEWS Zoning cannot approve any building permits until the Special Districts reviewer performs and approves their review. TECHNICAL STANDARDS MANUAL REFERENCES: SECTION 5: LANDSCAPING AND SCREENING https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-11368 SECTION 7: PEDESTRIAN ACCESS https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-11582 |
|||
| ROW Engineering Review * | REVIEW COMPLETED | DTM Review Comments: Full ROW Compliance to be required - At this of Development permit submission Plan to call out all ROW features for Linden St and for Alleyway- Centerline, ROW width, Utility locations & any proposed location of row impact in the right of way. ---- E Linden St frontage 1) Driveway will be require to meet PAG 206 Standard detail, TSM 10-01.4.3, and City Policy Chapter 25-38 for Residential Driveway placement 2) Sidewalk meeting PAG 200 standard detail 5' minimum width with 3' Minimum Buffer between Sidewalk and Back of Curb required 3) E Linden pavement was restored in October 2025 and will be under pavement moratorium status for 3 yrs. 4) All Work performed in the Right of Way will required separate ROW-Development permit submission per scope of work. -- Tri-plex location at rear of the Parcel off Alleyway. -- 1) Alley ROW width is 15' and will require a minimum width of 20' to be used as a primary entry point Tri-plex. As well as will require minimum of chip seal up to the proposed property and parking area. 2) Tri-plex has no shown Pedestrian Circulation connection to a ROW frontage and pedestrian route. |
|||
| Site Engineering * | REVIEW COMPLETED | Permit Activity Number: TP-PRE-0826-00165 Project: Triplex Location: 1728 E LINDEN ST Review Date: 8/20/2026 Reviewer: Ryan Insalaco – Engineering Associate - Site Engineering Related Cases: *This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code.* City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf Site Engineering Review Comments: 1. Per the City of Tucson Inclusive Home Design Ordinance https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf, all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway (or apron), sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in 2017 ICC A117.1 Sections 402-403, including the minimum 4ft-width, slope and composition materials. 2. Secondary alley access will not be permissible as the current alley width is 15ft and does not meet UDC 7.10.1. See zoning review comments. 3. Sidewalks shall be flood free for all storm discharges of up to and including a ten-year frequency flood event. Drainage flowing across all pedestrian circulation paths shall be designed and constructed to convey flows under the path for up to and including the ten-year frequency flood events, except at street intersections, pedestrian crossings, and PAAL pedestrian crossings. [TSM 7-01.4.1.E & 7-01.4.3.E] a. Provide keynotes and call-outs identifying all downspouts and sidewalk scupper locations on all related permits site plan and/or building sheets. This information is required to demonstrate compliance and to ensure coordination with building permit plan review. b. If downspouts from rooftops are to be discharged at grade-level, ensure that the stormwaters up to and including flow from a 10-year event are directed away from accessible parking stalls. *** Please note: this review is for Pre-Application purposes. Please be aware that additional comments may be forthcoming during formal review process. If you have any questions or concerns, please contact Ryan Insalaco – ryan.insalaco@tucsonaz.gov |
|||
| TW New Area Development * | REVIEW COMPLETED | Based on the information provided, Tucson Water has no objections to the proposed development. The building currently has one existing domestic water meter size (1-inch). This service is connected to the 6-inch cement asbestos water main (B Zone) located within the north side of the parcel within the right-of-way of E Linden St. The existing infrastructure should be sufficient for the proposed project. However, if any new domestic water, irrigation water, or fire water services are needed to serve this proposed development, please contact Tucson Water’s New Services Section by calling 520-791-5164 or by sending an email to TW_Common@tucsonaz.gov. Water pressure in this area is 67-74 PSI at an elevation of 2428ft. Water pressure can vary by an additional 5 psi +/-. There are plans to repave Linden Street. Please coordinate with the City of Tucson Department of Transportation and Mobility (DTM) to confirm the paving schedule and whether the proposed work will be subject to the City’s 5-year pavement cut moratorium. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to Abdullah Salman (Project Manager) at Abdullah.Salman@tucsonaz.gov |