| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Fire New Construction * | REVIEW COMPLETED | TP-PRE-0825-00167 • Pre-Application Conference Review v1 • 1541 E 2ND ST TUCSON, AZ 85719: 1. Provide aerial access in accordance with IFC 2024, Appendix D 105.1 (please note TFD will not accept trees with mature height over 20' on the aerial access side of the building.) Questions: patricia.shelton@tucsonaz.gov / 520.837.7082 |
|||
| ROW Engineering Review * | REVIEW COMPLETED | No comments | |||
| Site Engineering * | REVIEW COMPLETED | Permit: TP-PRE-0825-00167 Location: 1541 E 2ND ST Review Date: 9/10/2025 Site Engineering Comments: 1. A grading plan with cut/fill quantities and area of disturbance will be required with this project. 2. Provide Waste Stream Calculations as well as Trash Enclosure detail. Technical Standards Manual 8-01.8.0 3. First Flush Retention/balanced basin detention will be required for this development, A drainage report will be required to show compliance with Design Standards for Stormwater Detention and Retention Manual Chapters 2, 3, and 4. 4. Pedestrian Circulation will be required to connect all buildings, dumpster areas, common areas and the sidewalk on the street frontages per TSM 7-01.3. 3. 5. ADA parking will be required. 6. This review is for Pre-Application purposes. Please be aware that additional comments may be forthcoming during submission process. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
|||
| Site Landscape * | REVIEW COMPLETED | CDRC TRANSMITTAL PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, RLA SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: DEMOLISH OLD SORORITY HOUSE AND REPLACE WITH NEW AND IMPROVED SORORITY HOUSE ACTIVITY NO: TP-PRE-0825-00167 ADDRESS: 1541 E 2ND ST ZONING: R-3 RESIDENCE ZONE LAND USE: RESIDENTIAL This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by the Site Landscape and NPPO section to ensure compliance with the applicable UDC development criteria and Technical Standards. SITE LANDSCAPE/NPPO COMMENTS: 1. The Site Landscape and NPPO review section has no comments or concerns with the rebuild of this house in the university area. Thank you. Chad Keller, RLA Landscape Architect chad.keller@tucsonaz.gov 520.837.4923 |
|||
| Site Zoning * | REVIEW COMPLETED | CDRC Thursday Pre-Submittal Transmittal FROM: Ramiro Olivarez PDSD Zoning Review Section PROJECT: Pre-submittal meeting TP-PRE-0825-00167 Address: 1541 E 2ND ST Zoning: R-3 Existing Use: Sorority Proposed Use: Group Dwelling | Sorority TRANSMITTAL DATE: September 11, 2025 COMMENTS: 1. Comment: The proposed development must comply with the City of Tucson Unified Development Code (UDC) Administrative Manual Chapter 2-06 – Development Package. Building permits (and demo) can be submitted and reviewed concurrently with the development package but the building plans cannot be approved until the development package is approved and the building plans are reviewed for consistency. 2. Comment: If applicable - Building, portions of buildings, or structures that are 50 years of age or older must be architecturally documented prior to demolition. Documentation will be reviewed and approved by the Historic Preservation Office before a permit is issued. Demolition (Historic Structures) Application and General Information may be downloaded at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Historic-Preservation/Historic-F…. Please submit the completed documentation under the permit number via your TDC online account. 3. Comment: Group dwelling sorority is an allowed use in the R-3 zone with the following Use Specific Standard 4.9.7.B.6. 4. Comment: In the R-3 zone there is not a minimum lot size. UDC TABLE 6.3-4.A. 5. Comment: Lot Size (min.) = N/A 6. Comment: Maximum lot coverage is 70%. 7. Comment: Setbacks for Nonresidential Use to Residential zone (min.) = 10’ or ¾(H) Without a west building height elevation, we are unable to determine the minimum required setback to the west property line. 8. Comment: All street setbacks are 20’. 6.4.5.C.2.b. For nonresidential and multifamily development abutting a Local Street: the minimum required street perimeter yard is 20 feet, as measured from the street property line. A Design Development Option (DDO) minimum will be required to reduce the both street setbacks. 9. Comment: The height maximum is 40 feet for nonresidential use. UDC TABLE 6.3-4.A. 10. Comment: Ensure compliance with Table 7.4.4-1: Minimum Number of Motor Vehicle Spaces Required for Group Dwelling - Sorority 0.7 space per resident. On projects where rent/lease of space is by the bedroom, the requirement is 0.85 space per bedroom or 2.00 spaces per dwelling unit, whichever is greater. Identify the ADA Van Accessible Parking spaces. 11. Comment: Per UDC 7.4.6.K.A., A street or alley cannot be used for maneuvering directly into or from any parking space located wholly or partially outside the public right-of-way. As the site is being demoed and redeveloped, the site will need to be brought up to full code compliance including vehicle parking. The depicted vehicle parking is not compliant with UDC 7.4.6.K.A. A Variance or Zoning Determination Letter (from the Zoning Administrator) may be required based on the existing vehicle parking and historic precedent. 12. Comment: Ensure compliance with Table 7.4.8-1: Minimum Required Bicycle Parking Spaces – a. For Group Dwellings - Short-term Bicycle Parking is 0.10 spaces per bedroom and the minimum requirement is 2 spaces. b. For Group Dwellings - Long-term Bicycle Parking is 0.5 spaces per bedroom and the minimum requirement is 2 spaces. Upon formal submittal clearly identify short and long-term bicycle parking. 13. Comment: Ensure bike parking design is compliant with 7.4.9 of the UDC. 14. Comment: Ensure compliance with Table 7.4.11-1: Minimum Required EVSE – a. Group dwellings EV Installed is not required. b. Group dwellings EV Ready Required is 10%. c. Group dwellings EV Capable Required is 20%. 15. Comment: Ensure EV Parking Design is compliant with 7.4.12 of the UDC. 16. Comment: While loading zones are not required, the depicted loading zone must comply with UDC section 7.5.4. Design Criteria. 17. Comment: Ensure the site complies with section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual. a. The pedestrian circulation paths must comply with 7-01.3: Within all development, a continuous pedestrian circulation path is required as follows: A. This path must connect all public access areas of the development and the pedestrian circulation path located in any adjacent streets. B. The areas within the development which must be connected include, but are not limited to, all buildings, all bicycle and vehicle parking areas, all recreation areas, all dumpster areas, and all other common use areas. The proposed pedestrian circulation appears to comply with section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual. 18. Comment: The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the review process, a full review will be made by Zoning to ensure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at Ramiro.Olivarez@tucsonaz.gov |
|||
| TW New Area Development * | REVIEW COMPLETED | TP-PRE-0825-00167 (1541 E 2ND ST TUCSON, AZ 85719) Plans to demolish old sorority house and replace with new and improved sorority house with more modern design Based on the information provided, Tucson Water has no objections to, or comments on, the proposed development. There are two existing meters located on the southeast side of the building. Based on the plan sketch provided, it appears that these existing meters will be sufficient to accommodate the requirements of the proposed project. If any new domestic water, irrigation water, or fire water services are needed to serve this proposed development, please contact Tucson Water’s New Services Section by calling 520-791-5164 or by sending an email to TW_Common@tucsonaz.gov. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Abdullah Salman | Project Manager Tucson Water - New Area Development Abdullah.Salman@tucsonaz.gov |