Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Plan Number: TP-PRE-0825-00164
Parcel: 11304347B

Review Status: Approved

Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1

Plan Number - TP-PRE-0825-00164
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
Entitlements * REVIEW COMPLETED Development must conform to the Preliminary Development Plan for rezoning case TP-ENT-0823-00035. The submitted plans show a substantial alteration to the approved Preliminary Development Plan. There are changes to building layout, vehicular access, solid waste facilities and parking.

It also appears the shipping container enclosure is being proposed as an outdoor event space, which would not be allowed in proximity to residential land uses per the rezoning.

Development plan should demonstrate conformance to conditions of rezoning, including flush curbs and basins in the parking and landscaping areas to demonstrate the application of passive rainwater harvesting to the greatest extent possible (Rezoning Condition 11, 12), including the proposed landscaped area east of the office area (Keynote 4).
Fire New Construction * REVIEW COMPLETED TP-PRE-0825-00164 • Pre-Application Conference Review v1 • 1145 E FORT LOWELL RD TUCSON, AZ 85719:
Based on the information provided TFD has the following comments:
1. Provide Knox access at gates. IFC 24, 503.6, 506.1
Questions: patricia.shelton@tucsonaz.gov / 520.837.7082
ROW Engineering Review * REVIEW COMPLETED DTM Review Comments

Sidewalk Installation
All proposed sidewalk installations must conform to PAG 200 standards for local and arterial roadway dimensions and must not exceed a 2% slope. (See attached PDF.)

Proposed Gate Placement – Ft. Lowell Rd (Southwest Corner)
Review the proposed gate placement at the southwest corner of the project along Ft. Lowell Rd. The gate must be set back sufficiently from the back of curb to allow a vehicle to stop completely outside the roadway. Additionally, the design should accommodate space for a vehicle to turn around in case of an emergency or gate malfunction, without requiring the vehicle to back into arterial traffic.

Unused Driveways and Curb Cuts
All unused driveways and curb cuts must be removed and the area fully built out to match the adjacent sidewalk and curb conditions.

Sidewalk – Navajo Rd (North Side of Property)
Sidewalk must be extended to the end of the property line along Navajo Rd. All associated driveway access points must be constructed to meet PAG 206 standards. (See attached PDF.)

Driveways
All proposed driveways are to be constructed with full concrete build-out and must comply with PAG 206 standards.

Fencing/Wall – Ft. Lowell Rd and Navajo Rd
Plans indicate a proposed fence/wall along Ft. Lowell Rd and Navajo Rd. Ensure that sight visibility requirements are met at the southeast corner of the property (intersection of Ft. Lowell and Navajo). Clearly note compliance with sight visibility standards and specify fencing mater

Thank you,
Zane Swenson
Engineering Associate
Dept. of Transportation and Mobility | Engineering Division
| Zane.Swenson@Tucsonaz.gov
Site Engineering * REVIEW COMPLETED Permit: TP-PRE-0825-00164
Location: 1145 E FORT LOWELL RD
Review Date: 9/4/2025
Site Engineering Comments:
1. This Site Resides within the Navajo Wash FEMA AE Floodplain. Site development will require a floodplain use permit for the work within the floodplain. Any new structures will be required to also have elevation certificates with required finish floor elevations to be determined through a required drainage report.
2. An in-depth encroachment analysis will be required. Tucson Code Chapter 26 section 26-5.2
3. Conex containers are not advisable as this area has been seen to have high flow velocities and significant flooding.
4. The western building records show that the structure has sustained substantial damage in the past. Any repairs/modifications to that structure will require that the building be brought to AZ floodplain regulations.
5. Flood venting will be required for the current perimeter CMU wall. Tucson Code Chapter 26 Section 26-8
6. Sight Visibility triangles will be required for all site entrances/exits. Fort Lowell is an Arterial Road. Technical Standards Manual 10-01.5.0
7. Pedestrian access will be required to connect to All structures, trash enclosures, and street frontage such as E Fort Lowell RD TSM 7-01.0.0
8. Waste Stream calculations will be required. Ensure to include a detail showing trash truck maneuverability TSM 8-01.0.0
9. A conceptional grading plan will be required for this development due to the floodplain status. Tucson Code Chapter 26 Section 26-8.a.3
10. It is suggested to maximize water harvesting into any landscaping.
11. This review is for Pre-Application purposes. Please be aware that additional comments may be forthcoming during submission process.

If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
Site Landscape * REVIEW COMPLETED CDRC TRANSMITTAL
PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
REVIEWER: CHAD KELLER, RLA
SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION

PROJECT: REDEVELOPMENT OF EXISTING SITE AS A COMMERCIAL EVENT SPACE & PROPOSED CONEX CONTAINERS
ACTIVITY NO: TP-PRE-0825-00164
ADDRESS: 1145 E FORT LOWELL RD
ZONING: O-3 OFFICE ZONE

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting.

The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by the Site Landscape and NPPO section to ensure compliance with the applicable UDC development criteria and Technical Standards.

REZONING COMMENTS PER PREVIOUS SITE LANDSCAPE REVIEWER FOR REFERENCE:

ACTIVITY NO: TP-ENT-0823-00035 ADDRESS/PARCEL NO: 1145 E FORT LOWELL RD/113-04-3470 ZONING: O-3, R-2 REZONING: C-2 EXISTING USE: GREEK ORTHODOX CHURCH PROPOSED USE: CORPORATE HQ TRANSMITTAL DATE: AUGUST 25TH, 2023 DUE DATE: SEPTEMBER 7TH, 2023 COMMENTS:

1. Due to the nature of the existing site, all NPPO conditions will be waived.
2. Setback reductions on the northwest portion of the site adjacent to APN 113-04-345A cannot be granted due to the lack of available space to meet any of the other landscape border areas.
3. This project will be required to have a separate water meter for irrigation.
4. Maximize the rainwater harvesting across the site into the landscape areas, including but not limited to the street landscape borders as well as the tree wells for the required trees for the parking lot.
5. As commercial rainwater harvesting will be next to impossible to achieve based on the existing conditions of the site, the applicant will have to use flush curbs and parking blocks in the parking areas to achieve the highest percentage of rainwater harvesting possible on the existing site.

SITE LANDSCAPE/NPPO COMMENTS:

1. A landscape plan is required.

2. Provide the required number of trees in all vehicular parking areas (1 tree to 4 parking spaces) per UDC 7.6.4.B.1. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a.

3. A drip irrigation plan and details are required for all proposed landscape planting areas.

4. DTM review is required for all planting and irrigation in the ROW prior to the approval of the development package. Reach out to David Marhefka (david.marhefka@tucsonaz.gov) if necessary for this project.

5. All landscape plans shall incorporate water conserving design as defined in UDC Section 7.6.6, Use of Water, and as described in the Technical Standards Manual 5.01-5.11.

Thank you.
Chad Keller, RLA
Landscape Architect
chad.keller@tucsonaz.gov
520.837.4923
Site Zoning * REVIEW COMPLETED CDRC Thursday Pre-Submittal Transmittal
FROM: Bobby Parsons, Planner
PDSD Zoning Review

PROJECT: Pre-submittal meeting TP-PRE-0825-00164
Address: 1145 E. Fort Lowell Rd. Tucson, AZ 85719
Existing Zoning: O-3/R-2 Proposed Zoning: C-2
Existing Use: Former Church
Proposed Use: Office/Educational Use

TRANSMITTAL DATE: 9/4/2025

COMMENTS:

1. Development must comply with the Administrative Manual Section 2-06, Development Package/Tentative Plat. Per the rezoning application, the Preliminary Development Plan (PDP) must be consistent with the Development Package (AM 2-06).

2. Administrative and Professional Office is an allowed use in the C-2 zone subject to Use Specific Standards UDC 4.9.13.B:
A. The principal use is restricted to hours of operation between 7am and 10pm.
Religious Use is an allowed use in the C-2 zone with no associated Use Specific Standards.

3. Per UDC Table 6.3-4.A, the following Dimensional Standards apply for the C-2 zone:
A. Lot Coverage is not applicable
B. The maximum height is 40’ measured from Design Grade.
C. Setbacks are as follows:
a. Nonresidential use to a residential zone: 1 ½ (Height of the proposed exterior wall)
b. Nonresidential use to a nonresidential zone: 0’
c. Street Perimeter Yard (UDC 6.4.5.C.2.a&b):
i. For nonresidential and multifamily development abutting an arterial or collector street, the minimum required street perimeter yard is 10’, as measured from the existing or future property line as determined by the adopted major streets and routes plan, whichever is greater.
ii. For nonresidential and multifamily abutting a local street, the minimum required street perimeter yard is 20’, as measured from the street property line.

4. Ensure compliance with UDC Table 7.4.4-1: Minimum Number of Motor Vehicle Spaces Required. Based on the parking calculations provided, an Individual Parking Plan (IPP) will be required.
A. Civic/Religious Use: 1 space per 100 sq. ft. GFA in all combined public assembly areas. (9,300 sq. ft. = 93 spaces required)
B. Office Use: 1 space per 300 sq. ft. GFA. (8,350 sq. ft. = 28 spaces required)
C. Storage Use: 1 space per 5,000 sq. ft. GFA. (4,500 sq. ft. = 1 space required)
D. Post Secondary Institution Use: 1 space per 200 sq. ft. GFA. (4,000 sq. ft. = 20 spaces required)

5. Ensure access complies with section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual.
A. The pedestrian circulation paths must comply with 7-01.3: Within all development, a continuous pedestrian circulation path is required as follows:
a. This path must connect all public access areas of the development and the pedestrian circulation path located in any adjacent streets.
b. The areas within the development which must be connected include, but are not limited to, all buildings, all bicycle and vehicle parking areas, all recreation areas, all dumpster areas, and all other common use areas.

6. EV Requirements:
A. Administrative & Professional Office: 5% EV Ready and 15% EV Capable

7. Bike Parking:
A. Religious:
a. Short Term: Spaces for 2% of the maximum expected daily attendance.
b. Long Term: 1 space per 20 employees. Minimum 2 spaces required.
B. Administrative & Professional Office:
a. Short Term: 1 space per 20,000 sq. ft. GFA. Minimum 2 spaces required.
b. Long Term: 1 space per 6,000 sq. ft. GFA. Minimum 2 spaces required.

8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions, please contact me at Robert.Parsons@tucsonaz.gov.
TW New Area Development * REVIEW COMPLETED TP-PRE-0825-00164 (1145 E FORT LOWELL RD TUCSON, AZ 85719)
Redevelopment of existing site as a commercial event space & proposed conex containers

Based on the information provided, Tucson Water has no objections to, or comments on, the proposed development.
A water meter is located at the northeast corner of the building, connected to an 8-inch (CA) cement asbestos potable water main (A zone). This meter provides the current water service to the property.

If any new domestic water, irrigation water, or fire water services are needed to serve this proposed development, please contact Tucson Water’s New Services Section by calling 520-791-5164 or by sending an email to TW_Common@tucsonaz.gov.

The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Abdullah Salman | Project Manager
Tucson Water - New Area Development
Abdullah.Salman@tucsonaz.gov