Plan Review Detail
Review Status: Approved
Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1
Plan Number - TP-PRE-0824-00187
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
Design Review | REVIEW COMPLETED | Design Professional's review PDF file has been uploaded into TDC and PRO. Design Professional will not be available the first two weeks of September 2024; if you would like to discuss with him his review, please let me know times that work best for you during the week of Sept. 16 or Sept. 23: maria.gayosso@tucsonaz.gov. Thank you, | |||
External Reviewers - COT Environmental Services | REVIEW COMPLETED | 1. Provide detail, with dimensions, of the trash room storage area and path to the container staging/collection area. Refer to TSM 8-01.4.0 and 8-01.5.0 for enclosure/storage specifications and access and maneuvering requirements. 2. Clarify if there will be chutes running from the top floor to the trash room and whether equipped with a compactor. Also, identify the proposed size of the containers and how many. 3. The proposed collection area should not obstruct vehicle traffic on Bonita Ave. Feel free to contact me regarding my review comments. Andy Vera (520) 837-3798 Andy.Vera@tucsonaz.gov |
|||
Fire New Construction | REVIEW COMPLETED | TP-PRE-0824-00187 • Pre-Application Conference Review v1 • 701 W CONGRESS ST TUCSON, AZ 85745: Based on the information provided, TFD has no comments at this time. * Prior to submittal please update plan to include no covered parking is permitted at the south side of the parking area, due to the reduction of fire lane for aerial access. Questions: patricia.shelton@tucsonaz.gov / 520.837.7082 |
|||
Historic | REVIEW COMPLETED | This is a contributor to Menlo Park National Register Historic District. The concept plan recognizes the importance of the adjacent contributing resource, only the lower section is close to the resource and ample distance is given between the properties. With no elevations provided the privacy concern and impacts on exterior changes could not be evaluated. Need to comply with historic guidelines per the Secretary of the Interior (SI). Contact: Michael.Taku@tucsonaz.gov |
|||
ROW Engineering Review | REVIEW COMPLETED | TP-PRE-0824-00187 • 701 W CONGRESS ST 1. The pedestrian circulation path along projects property frontage shall be brought into compliance with Sec. 10-01.4.0. of the UDC Technical Standards Manual. This includes replacing any out of compliance curb access ramp and replacing any sidewalk sections that are broken/cracked or where the cross slope exceeds 2%. 2. All abandoned curb openings will have to be closed with matching curb. If you have any questions, please contact Richard Leigh at 520-403-0970 or email richard.leigh@tucsonaz.gov. |
|||
Site Engineering | REVIEW COMPLETED | Tucson codes and ordinances can be found online at: https://codelibrary.amlegal.com/codes/tucson/latest/overview The Design Standards for Stormwater Detention and Retention (DSSDR) manual can be found online at: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf 1. Please include area of disturbance and cut/fill quantities on the plan set. 2. A Floodplain Use Permit with Elevation Certificate will be required for the building in this development. The base flood elevation is 2346.81 feet NAVD88. Therefore, the minimum finished floor elevation shall be 2347.81 feet NAVD88. 3. Maximize rainwater harvesting by depressing landscape areas 6-9 inches, grading towards them, and using curb cuts or flush curbs where feasible. 4. Please provide ADA parking spaces compliant with ADA Accessibility Standards Chapters 208 and 502. A minimum of three ADA spaces are required with the current number of proposed parking spaces, and at least one ADA space must be van-capable. 5. The refuse collection proposal is not standard. Please provide approval from Andy Vera (Andy.vera@tucsonaz.gov ) for the refuse collection proposal. Mike Ortiz michael.ortiz@tucsonaz.gov |
|||
Site Landscape | REVIEW COMPLETED | CDRC TRANSMITTAL PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, RLA PDSD LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: 5 STORY MULTIFAMILY DEVELOPMENT WITH 47 UNITS ACTIVITY NO: TP-PRE-0824-00187 ADDRESS: 701 W CONGRESS ST ZONING: C-3 LAND USE: MULTIFAMILY/COMMERCIAL This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to ensure compliance with the applicable UDC development criteria and Technical Standards. SITE LANDSCAPE/NPPO COMMENTS: 1. A NPPO Waiver is required per UDC 7.7.3-B. A Native Plant Preservation Plan, Section 7.7.4, must be submitted and approved or a request for an exception from the Native Plant Preservation requirements shall be approved in accordance with Sections 7.7.3.D.3 & .4 of the UDC and Administrative Manual Section 2-11.0.0 prior to Grading Plan approval. PDSD will provide the applicant with the NPPO Waiver form upon request. 2. A landscape plan is required per UDC 7.6.2.B.1-b. The Unified Development Code requires all new development, or an expansion of greater than 25% of an existing development to submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4 and Administrative Manual 2-10. 3. Provide the required number of trees in all vehicular parking areas (1 tree to 4 parking spaces) per UDC 7.6.4.B.1. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a. 4. A street landscape border is required on W Congress St and along W Bonita Av per UDC 7.6.4.C-2 and Table 7.6.4-1. See UDC 7.6.4.C for landscape border requirements. 5. DTM approval is required for all planting and irrigation in the ROW prior to the approval of the development package. Reach out to David Marhefka (David.marhefka@tucsonaz.gov) if necessary for this project. 6. All landscape plans shall incorporate water conserving design as defined in UDC Section 7.6.6, Use of Water, and as described in the Technical Standards Manual 5.01-5.11. 7. A Commercial Rainwater Harvesting plan is required per UDC Technical Standards Manual – Section 4-01.3.0. and Section 5-01.0.0 Landscaping and Screening. Adherence to the Low Impact Development Standards outlined in Section 5 of the PCRFCD Design Standards is required. 8. The Landscape Plan should match the Commercial Rainwater Harvesting Plan as well as the Grading Plan. The Landscape Plan should have spot elevations in the detention/retention areas as well as in all water harvesting areas in the Landscape Plan. 9. Maximize the rainwater harvesting across the site into all landscape areas, including the street landscape borders and planting islands for the required trees in the parking area. 10. The Commercial Rainwater Harvesting Plan must utilize the Site Water Budget. See TSM 4-01.3.1 Exhibit A. If a copy of the water budget spreadsheet is needed, please reach out to Site Landscape/NPPO and I will provide the spreadsheet. The Site Water Budget is how the Water Department tracks the irrigation water use on-site. 11. A separate irrigation water meter is required. Please label irrigation meter as “irrigation only”. See TSM 4-01.6.0 GENERAL IID COMMENTS: 12. Streetscape design must comply with the design in the Technical Manual and the Streetscape Design Policy. 13. Except as provided below, shade shall be provided for at least 50% of all sidewalks and pedestrian access paths as measured at 12:00 p.m. on June 21 when the sun is 80 degrees above the horizon. Shade may be provided by trees, arcades or canopies provided their location and design characteristics are compatible with the historic design context and the architectural integrity. The use of plantings and shade is permitted to meet this standard, with the approval of DTM. The shade provided may serve to meet this standard. - b. Exception - The PDSD Director may approve an IID Plan providing less than 50% shade, where compliance is not feasible due to a location and/or orientation and the applicant has made a reasonable attempt to comply with this standard. If you have any questions about these comments, I can be reached at chad.keller@tucsonaz.gov |
|||
Site Zoning | REVIEW COMPLETED | CDRC TRANSMITTAL TO: Planning & Development Services Department FROM: Fernando L. García PDSD Zoning Review Section PROJECT: 701 W Congress St., Tucson, AZ 85745 Parcel(s): 116-19-131A Zoning: C-3 Commercial Pre-Submittal Conference (1st Review) TP-PRE-0824-00187 TRANSMITTAL DATE: August 5, 2024 DUE DATE: August 5, 2024 1. The proposed development must comply with the City of Tucson Unified Development Code (UDC) Administrative Manual Chapter 2-06 – Development Package. Building permits can be submitted and reviewed concurrently with the development package but the building plans cannot be approved until the development package is approved and the building plans are reviewed for consistency. 2. The project is located within the Greater Infill Incentive Subdistrict (GIIS) of the Downtown Area Infill Incentive District (IID) Urban Overlay Zone. Pre-application documents indicate that the applicant intends to pursue development of the site(s) under the guidelines of the IID overlay. If you are planning to use the IID as a tool for development/redevelopment, please submit a special districts application as a sub-record of the development package, once submitted. In addition, please refer to the Special Districts Application Process guide for a complete list of materials required for this project. https://www.tucsonaz.gov/files/pdsd/forms/Special_Districts_Application_Instructions.pdf. The IID is regulated by UDC Section 5.12; the GIIS is specifically cited in UDC Section 5.12.9. 3. The following dimensional standards apply to the C-3 zone prior to any IID-related modifications. Per UDC Table 6.3-4.A, residential density in a C-3 zone is 87/acre. There is no lot coverage maximum. Height is limited to 75’. Setbacks to the north where the property abuts a residential zone are 1.5 time the building wall height. Setbacks to Bonita, a local street, are 20’. Setbacks to Congress, an arterial road, are 10’. Setbacks to the west are 10’. 4. Per UDC Table 7.4.4-1, the minimum number of motor vehicle spaces required is 61 prior to any reductions. Accessible parking space requirements are based on pre-reduction parking spaces requirements and cannot be reduced by the IID. Two standard accessible spaces and one van-accessible space is required. 5. Per UDC Table 7.4.8-1, the minimum required number of short-term bicycle parking spaces is 5. The minimum required number of long-term bicycle parking spaces is 24. 6. Per UDC Table 7.4.11-1, 10% of motor vehicle parking spaces are required to be EV Ready. 20% are required to be EV Capable. 7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, the Zoning Review Section will conduct a full review to assure compliance with applicable UDC development criteria and technical standards. If you have any questions, please contact me at fernando.garcia2@tucsonaz.gov. |
|||
TW New Area Development | REVIEW COMPLETED | TP-PRE-0824-00187 - Pre-Application Conference Review v1 – 701 W CONGRESS ST - Multifamily Development Tucson Water offers the following comments for your convenience: 1. There is an existing 6” cement asbestos water main in Bonita Ave that should be able to supply this project’s domestic potable water and irrigation water needs. But, to get the amount of fire flow you will need for this project you may need to connect this project’s fire service to the existing 10” water main in Congress Street. 2. The ‘as-built’ plan numbers for these existing water mains are shown on Tucson Water’s NE141413 valve map. Copies of the valve maps and ‘as-built’ plans referenced in these comments may be obtained from Tucson Water’s Mapping & GIS Center by sending an e-mail request for them to TWMapInfo@tucsonaz.gov. 3. Based on the elevation of the site, the water pressure at ground level is expected to be in the 63-70 psi range. 4. The required water meter size for each commercial building will be determined by a water fixture count conducted in accordance with the 2018 International Plumbing Code and Tucson Water’s Water Meter Sizing Guidelines. Tucson Water’s Water Meter Sizing Guidelines are available at https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/tucson-water/documents/signed_meter_sizing_guidelines_march_2020.pdf 5. If a 3” or larger water meter is needed for this development, the water meter will need to be located within a large meter enclosure that is a minimum of 25’ long x 10’ wide x 5’ high per Tucson Water Standard Detail SD-314. The entire large meter enclosure must be located on the property in a water easement granted to the City of Tucson. 6. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |