Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Plan Number: TP-PRE-0823-00298
Parcel: 12904138A

Address:
24 N NORRIS AV

Review Status: Approved

Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1

Plan Number - TP-PRE-0823-00298
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
Design Review REVIEW COMPLETED This property is within the boundaries of the Sunshine Mile Urban Overlay District (SMD), Mid-Century Subdistrict. The two structures on site are designated contributors to the Sunshine Mile National Historic District. If the SMD will be used as a tool for redevelopment, please send me an email to maria.gayosso@tucsonaz.gov so we can schedule a presubmital meeting with the Design Professional, the Historic Preservation Officer, and other staff as needed. Here's an overview of the SMD: https://www.tucsonaz.gov/files/sharedassets/public/city-services/planning-development-services/documents/smd_handout_forweb.pdf. Here's the SMD document: https://www.tucsonaz.gov/files/sharedassets/public/city-services/planning-development-services/documents/smd_document_final_9-14-21.pdf . Thank you.
Fire New Construction REVIEW COMPLETED TP-PRE-0823-00298 • Pre-Application Conference Review v1 • 24 N NORRIS AV TUCSON, AZ 85719: Based on the information provided, TFD has the following comments:
1. Provide fire sprinkler systems in accordance with 2018 IFC, 903.3.
2. Provide fire alarm systems in accordance with 2018 IFC, 907.
Questions: patricia.shelton@tucsonaz.gov / 520.837.7082
Historic REVIEW COMPLETED Property is listed as a contributing resource to the Sunshine Mile National Register Historic District (NRHD) and Urban Overlay District (UOD).
Since the property is city-owned and within a NRHD, AD 1-07.7 requires review by the Plans Review Subcommittee. When submitting for the permit, please provide the updated documentation.
Demolition of the contributing resource eliminates the use of the UOD as noted in the Sunshine Mile UOD document, unless it can be relocated. Per Section K.3.c(2), if relocation proves physically or economically infeasible demolition may be
allowed after preparation of a Historic American Buildings Survey (“HABS”)
Level III report (to be reviewed and approved by the CHPO) and pursuant
to UDC Section 5.8.10.E., Demolition Review for Historic Contributing
Properties and Historic Landmarks. Section 5.8.10.E provides all the documents that will be need to show economic infeasibility that will need to be provided.
Site Engineering REVIEW COMPLETED Tucson codes and ordinances can be found online at https://codelibrary.amlegal.com/codes/tucson/latest/overview
The Design Standards for Stormwater Detention and Retention manual can be found online at https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf

1. APC and alley use will required ES approval, please reach out to andy.vera@tucsonaz.gov
2. Pedestrian circulation will be required out to the waste enclosure as well as to Broadway and Norris
3. Balanced basin detention and first flush retention will be required based on any new disturbed and impervious area.
4. Maximize water harvesting into any landscaping through the use of curb cuts, flush curbs, or scuppers
5. Provide adequate area in front of gate for someone without gate access to maneuver and turn around without needing to back into the right of way. Vehicles cannot back out into the MS&R per Tucson Code 25-16.2

Lianne Evans
lianne.evans@tucsonaz.gov
Site Landscape REVIEW COMPLETED CDRC TRANSMITTAL
PROJECT: FIRE STATION 3
ACTIVITY NO. TP-PRE-0823-00298
ADDRESS/PARCEL: 24 N NORRIS AV/129-04-138A
ZONING: R-2

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.

The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to assure compliance with the applicable UDC development criteria and Technical Standards.

COMMENTS:
1. If the landscape architect is from outside of the City of Tucson and is unfamiliar with the development code requirements around landscaping, it is HIGHLY recommended they reach out to Matthew Carlton at their earlies convenience to work through any submittal issues that may arise.
2. There must be a NPPO waiver. An NPPO is required per UDC 7.7.3-B. A Native Plant Preservation Plan, Section 7.7.4, is required to be submitted or approved or a request for an exception from the Native Plant Preservation requirements approved in accordance with Sections 7.7.3.D.3 & .4 of the UDC and Admin. Manual Section 2-11.0.0 prior to Grading Plan approval.
3. A landscape plan is required per 7.6.2.B.1-b. The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development to submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4 and Administrative Manual 2-10.
4. There also needs to be an irrigation plan and all associated details.
5. Ensure the required number of trees is in all vehicular parking areas (1 tree: 4 parking spaces) per UDC 7.6.4.B.1. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a. In the case of this protective services building, Landscape/NPPO will allow parking diamonds to achieve this.
6. There will need to be a street landscape border on Norris Av & UDC 7.6.4.C-2 and Table 7.6.4-1. See UDC 7.6.4.C for landscape border requirements.
7. See Engineering notes for Retention/Detention.
8. All landscape plans shall incorporate water conserving design as defined in UDC Section 7.6.6, Use of Water, and as described in the Technical Standards Manual 5.01-5.11.
9. Maximize the rainwater harvesting across the site into the landscape areas, including but not limited to the street landscape borders as well as the tree wells for the required trees for the parking lot.
10. A Commercial Rainwater Harvesting plan is required per UDC Technical Standards Manual – Section 4-01.3.0. and Section 5-01.0.0 Landscaping and Screening. Adherence to the Low Impact Development Standards outlined in Section 5 of the PCRFCD Design Standards for Stormwater Detention and Retention is required and shall work in conjunction with the Commercial Rainwater Harvesting design. Using Low Impact Development design and water harvesting provides critical basin detention and first flush retention for all new development and impervious area. The newly adopted Detention/Retention Manual can be found: https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-final-201406-manual.pdf

With CoT edits to the manual are found at: https://www.tucsonaz.gov/files/pdsd/codes/Detention_Retention_Manual_Tech_Standards_Amemdments.pdf
11. The Commercial Rainwater Harvesting Plan must utilize the Site Water Budget (located here: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Water-Energy-Conservation). See TSM 4-01.0.0 Exhibit A. The Site Water Budget is how the Water Dept tracks the irrigation water use on-site, not first flush retention volume charts.

If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov or 520-837-4988
Site Zoning REVIEW COMPLETED CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Loran Shamis; Lead Planner

PROJECT: TP-PRE-0823-00298 – Fire Station No. 3
Address: 24 N Norris Av
Parcel(s): 12904138A
Zoning: R-2
Existing Use: civic – protective services
Proposed Use: civic – protective services

TRANSMITTAL DATE: August 31, 2023

COMMENTS:
1. The proposed development must comply with Administrative Manual 2-06 – Development Package. The Development Package and Building Permits may be submitted for concurrent review, however, the Building Permit cannot be approved prior to the Development Package approval.
2. The site is zoned R-2 and the proposed use is civic – protective services subject to use specific standard 4.9.13.F
a. In addition to the requirements of Section 7.6.5, Screening Standards, there shall be a screen wall at least five feet in height between this use and any residential.
3. The site is within the optional Sunshine Mile Urban Overlay District – Mid-Century Subdistrict, and some of the following standards required per the underlying zoning may be modified if the proposal opts into the SMD Overlay. Clarify if you will be opting into the SMD Overlay. Contact Maria Gayosso for more information – maria.gayosso@tucsonaz.gov.
4. Protectives services within the R-2 zone require a minimum lot size of 20,000 square feet and the lot coverage maximum is 60% (UDC 6.3.4, Table 6.3-2.A).
5. The maximum height permitted is 25’ (UDC 6.3.4, Table 6.3-2.A).
6. The minimum required setbacks for a nonresidential use adjacent to a nonresidential zone is the greater of 10’ or ¾ the height of the proposed building wall (UDC 6.3.4, Table 6.3-2.A). The setback along Broadway is 10’ from the future property line and the setback along Norris and Olsen is 20’ from the property line (UDC 6.4.5.C).
7. The required vehicle parking ratio for civic uses is 1 space per 300 square feet of gross floor area (UDC 7.4.4, Table 7.4.4-1).
8. The required bicycle parking ratio for short-term bicycle parking is 1 space per 8,000 square feet of gross floor area, a minimum requirement of 2 spaces. The required bicycle parking ratio for long-term bicycle parking is 1 space per 12,000 square feet of gross floor area, minimum requirement is 2 spaces (UDC 7.4.8, Table 7.4.8-1). See Design Criteria in UDC 7.4.9.
9. Provide a pedestrian circulation path that connects all areas of development and to any adjacent street frontage. The path must be ADA accessible and a minimum of 4’ wide (TSM 7-01).
10. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions, please contact me at Loran.Shamis@tucsonaz.gov.
Traffic Engineering Review REVIEW COMPLETED TP-PRE-0823-00298
24 N. Norris Ave.

Comments:
1. Existing pedestrian access along Norris Ave needs to be maintained. (Not the existing sidewalk, just ADA compliant access north along Norris.)
2. New entrances on Norris Ave will need to be ADA compliant for pedestrian travel north bound along Norris.
3. The tie-in at the alley on Norris needs to also be ADA compliant.
4. Concerning the angled entrance off of Broadway. The “Gate” posse’s potential problems if a random vehicle were to pull in, they would have to back out onto Broadway. This is not allowed. Options are,
a. Do not install the gate. Vehicles unintentionally pulling in there could then pull through out on to Norris and not have to back out into Broadway.
b. Provide an adequate turn-around at the end of the entrance. This would need to be drawn on the DP with dimensions and a standard single cab truck used to depict a Three-Point turn.

David Stiffey
DTM Project Coordinator
David.Stiffey@tucsonaz.gov
TW New Area Development REVIEW COMPLETED TP-PRE-0823-00298 - Pre-Application Conference Review v1 – 24 N NORRIS AV

1. Based on the information provided, Tucson Water has no objections to, or comments on, the proposed development.

2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov