| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Design Review | REVIEW COMPLETED | Design Professional - Preliminary Review for CDRC Date: 9 Aug 2023 From: R. Fe Tom, AIA Project: CDRC Pre-Application Review IID Case #: TBD Project Name: 1417 S 6th Ave, Adaptive Reuse Artist Studios Address: 1415, 1417 & 1419 S. 6th Ave. Pre-Application Activity Number: TP-PRE-0823-00284 Re: Design Professional Pre-submittal Review Comments for CDRC Review The purpose of this review is to provide Preliminary Comments for pre-submittal documents at the above address. The site is zoned C-3 and is within the Downtown Infill Incentive District (IID) and Greater Infill Incentive Sub-Area. This property contains historic buildings consisting of a single family residence, a store, a large garage, and a small detached garage. This property has the goal to meet a community need for multiple affordable 200-1000 sq/ft artist studio space and to offer revitalized commercial space on S. 6th Ave. Comments: Please have the Architect provide a Design Information Package for the above project to the Design Professional with the following information: A. Introduction to the above Project B. Provide photos for the context around the Project Site C. Provide Building Elevations (including dimensions of all building heights) and Material Finishes D. List Waivers or Exceptions to Development Standards requested E. This Project may require a Major IID Review if the proposal meets any two or more criteria listed in UDC 5.12.6.B.1 and/or UDC 5.12.6.B.2 F. Show compliance with the UDC Sections for the following items: 1. UDC 5.12.8: General IID Zoning Option Design Standards 2. UDC 5.12.9: Greater Infill Incentive Sub-District (GIIS) This concludes my Preliminary Review Comments for 1415, 1417 & 1419 6th Ave (Parcel 118122450). Further detailed review will be provided upon the submittal of the formal IID application. Fe Tom Richard Fe Tom, AIA COT Design Professional Reviewer |
|||
| Fire New Construction | REVIEW COMPLETED | TP-PRE-0823-00284 • Pre-Application Conference Review v1 • 1417 S 6TH AV TUCSON, AZ 85713: Based on the information provided, TFD has no comments at this time. Questions: patricia.shelton@tucsonaz.gov / 520.837.7082 |
|||
| Site Engineering | REVIEW COMPLETED | Tucson codes and ordinances can be found online at https://codelibrary.amlegal.com/codes/tucson/latest/overview The Design Standards for Stormwater Detention and Retention manual can be found online at https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf 1. Ensure solid waste enclosure design and maneuverability per TSM 8-01. 2. A back up spur will be required on the north side of the parking lot for maneuverability per UDC 7.4.6 F. 3. Ensure parking surfacing requirements meet UDC 7.4.6 I. Lianne Evans lianne.evans@tucsonaz.gov |
|||
| Site Landscape | REVIEW COMPLETED | Due to the existing nature of this site and the lack of any real changes to grading/drainage/landscape, Landscape/NPPO has no real concerns or questions about this project. If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov or 520-837-4988 |
|||
| Site Zoning | REVIEW COMPLETED | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Nicholas Martell, Principal Planner PROJECT: Thursday Pre-submittal meeting - TP-PRE-0823-00284 Address: 1417 S 6TH AV Parcel: 118122450 Zoning: C-3 Existing Use: Residential-Single Family Proposed Use: Commercial-Technical Service TRANSMITTAL DATE: August 9, 2023 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. Multifamily residential is permitted in the C-3 with the following use-specific standards: a. 4.9.4.W.2- The maximum permitted gross floor area is 3,500 square feet. b. Gross Floor Area is defined here: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-7793 c. Due to the limited GFA allowed for a Technical Service use in the C-3 zone, a variance may be an option. Otherwise; d. A Commercial-Artisan Residence use could be explored, subject to 4.9.4.E.1, .2, .3, .4, & .5: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-2222 3. The site is in the Greater Infill Incentive District (IID). Some zoning standards may be waived or modified with a complete application. Please contact Maria.Gayosso@tucsonaz.gov for more information. 4. Required parking is calculated as follows (Table 7.4.4-1 UDC); a. Commercial-Technical Services and Artisan Residence: 1 Space per 300 Square Feet Gross Floor Area. Parking may be waived through the IID. b. ADA spaces may only be waived through a Building Official waiver. 5.Perimeter Yard Requirements (6.4.5.A): Non-residential uses adjacent to non-residential zones (north and south) have 0’ setbacks adjacent to interior lots. a. Non-residential uses adjacent to residential zones (east) are required to maintain a 1 ½ (Height) distance away from the property line. 6. Street Setback Requirement (6.4.5.C): For nonresidential and multifamily development abutting an Arterial or Collector Street the minimum required street perimeter yard is ten feet, as measured from the existing or future property line as determined by the adopted Major Streets and Routes Plan, whichever is greater. a. 6th Avenue is a Major Street with a proposed width of 90’. Please confirm whether there is a plan to widen 6th avenue with a member of the Department of Transportation and Mobility (DTM). 7. The maximum height in the C-3 zone is 75’ (TABLE 6.3-4.A). 8. Ensure access standards found in section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met. 9. Please provide ADA parking per the building code. 10. The site may be eligible for adaptive re-use per 3.3.3.H of the UDC. While there appear to be small site improvements since May 1, 2005, zoning may be able to work with the applicant to gauge applicability 11. Please reach out to heather.thrall@tucsonaz.gov to discuss sign placement. 12. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions about this transmittal, contact me at Nicholas.Martell@tucsonaz.gov |
|||
| Traffic Engineering Review | REVIEW COMPLETED | No Comments David Stiffey David.Stiffey@tucsonaz.gov |
|||
| TW New Area Development | REVIEW COMPLETED | PRE-0823-00284 - Pre-Application Conference Review v1 – 1417 S 6TH AV 1. Based on the information provided, Tucson Water has no objections to, or comments on, the proposed development. 2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |