| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Fire New Construction | REVIEW COMPLETED | TP-PRE-0724-00158 • Pre-Application Conference Review v1 • 225 W FLORES ST TUCSON, AZ 85705: Based on the information provided, TFD has the following comments: 1. Provide fire alarm as required in 2018 IFC, 907 2. Provide fire sprinkler systems following 2018 IFC, 903 3. Provide Knox boxes per 2018 IFC, 506 *This project would also require an operational permit for a State Licensed Facility. Questions: patricia.shelton@tucsonaz.gov / 520.837.7082 |
|||
| ROW Engineering Review | REVIEW COMPLETED | PRE-0724-00158 (225 W FLORES ST TUCSON, AZ 85705) 1. Existing curb and sidewalk along the property frontage that is non-compliant shall be reconstructed to meet current standards. 2. A 5’ wide sidewalk shall be provided along the property frontage of 11th Ave and Flores St, Ref. TSM 10-01.2.7, 10-01-3.3 and 10-01.4.0. 3. Driveways shall be constructed in accordance with section 4.3. of the TSM and COTC 25-39. 4. Any unused curb cuts shall be close and restored with matching curb, Ref. COTC 25-43 and PAG SD 209. 5. A curb access ramp shall be provided at the SE corner of Flores St and 11th Ave and at the alley at the SW corner of the site on 11th Ave, Ref. 10-01.2.8. 6. CMU wall, corrugated fence and other encroachments within the public right-of-way, along Flores St will have to removed, Ref. COTC Sec. 25-13. Development Code (UDC) Administrative Manual (AM), Technical Standards Manual (TSM), Street Design Guide (SDG), Pima Association of Governments Standard Details (PAG SD), Access Management Guidelines (AMG), Major Streets and Routes Plan (MS&R), City of Tucson Public Utility Administrative Manual (PUAM), City of Tucson Department of Transportation and Mobility (COT DTM). If you have any questions, please contact Richard Leigh. at 520-403-0970 or at arnold.leigh@tucsonaz.gov |
|||
| Site Engineering | REVIEW COMPLETED | 1. Engineering has no comments. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
|||
| Site Landscape | REVIEW COMPLETED | 1. Based on preliminary information, it appears that the proposed project does not require any landscape work. However, Site Zoning will make a determination regarding parking requirements, and this decision may also result in landscape requirements. Please reach out if needed based on the Site Zoning determination. Mike Ortiz michael.ortiz@tucsonaz.gov |
|||
| Site Zoning | REVIEW COMPLETED | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Georgia Pennington, Planner PROJECT: Thursday Pre-submittal meeting Parcel(s): 115-06-0180 Zoning: C-2 Existing Use: Multifamily Proposed Use: Residential Care Services TRANSMITTAL DATE: 7/18/24 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 – Development Package. The Development Package is a separate submittal from the building permits, and the building permits cannot be approved until the Development Package is approved. 2. The existing zone is C-2. Residential Care Services is a permitted use in the C-2 zone, subject to Use-Specific Standards 4.9.7.J.1, 3.d, .4, .6, & .8. 3. Maximum Height (6.3-4.A): 40 Feet 4. Maximum Density: 44 Units/Acre 5. Setbacks: a. Front Street/Side Street: 10’(6.4.5) b. Side/Rear, Non-Res Non-Res: 0’ (6.3-4.A) 6. Motor Vehicle Space requirements (7.4.4): 1 space/2 beds -Parking Reductions and Exceptions can be found here: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5452 7. Bike Parking Requirements(7.4.9): a. Short term: 0.05 spaces per bedroom . Minimum requirement is 2 spaces. b. Long term: 0.10 spaces per bedroom . Minimum requirement is 2 spaces. 8. Parking Area Access Lanes (PAAL) shall be 24 feet wide for 2-way traffic and fire access. 9. Comply with Section 7-01 Pedestrian Access in the Technical Standards Manual for new construction. 10. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at Georgia.Pennington@tucsonaz.gov. |
|||
| TW New Area Development | REVIEW COMPLETED | TP-PRE-0724-00158 - Pre-Application Conference Review v1 – 225 W FLORES ST Tucson Water has no objections to the proposed development and offers the following comments for your convenience: 1. The proposed change in use MAY make this facility subject to the requirements of Section 609 of the 2018 International Plumbing Code. Tucson Water does not enforce this code, but the City of Tucson Planning and Development Services (PDSD) does. All questions about whether Section 609 of the 2018 International Plumbing Code applies to this project, or not, should be directed to Mr. Robert Sherry of the PDSD. He can be reached via email at robert.sherry@tucsonaz.gov. Unfortunately, I do not have a telephone number for Mr. Sherry. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |