Review Date Reviewer's Name Type of Review Description Status Comments
Entitlements REVIEW COMPLETED The applicant is requesting a Rezoning from Suburban Residence (SR) to Urban Residence (R-2) on 4.79 acres to accommodate a 26-lot single family residential subdivision terminating at a cul-de-sac. The proposed project has an approximate density of 5.4 dwelling units per acre with lot sizes of approximately 6,300 square feet along with two-story building heights up to 25-feet.
The proposed R-2 zoning is not compatible with the Pantano East Area Plan (PEAP) and the immediate adjacent R-1 zoned subdivisions. PEAP Policy 2A calls “Continue to promote low-density residential developments within the interior of established low-density neighborhoods.” Low density is defined as R-1 zoning. However, the proposed density of 5.4 dwelling units per acre is consistent with R-1 zoning and the PEAP definition of low-density of densities up to six (6) units per acre.
A request for R-2 zoning would require a plan amendment which is not supported by the Pantano East Area Plan.
The rezoning application will need to outline how the proposed project is compatible with the surrounding low density residential uses and preserves the integrity of the established neighborhoods.
It should be noted that the immediate adjacent residential subdivisions have R-1 zoning (see C9-85-05 and C9-74-68) with approximate densities of 3.54 and 4.21 dwelling units per acre based on 16 or 19 lots each on approximately 4.51 acres are more appropriate.
Rezoning – Planning & Development Services Pre-submittal Review Page 4 of 5
TP-PRE-0625–00122 - 9220 E Rosewood Street (Ward 2)
The current proposal will need to demonstrate how the proposed increase in units and two-story heights are compatible with the adjacent single-story residential units. Typically, residential infill projects provide one-story or combination of one and two-story structures when adjacent to single-story units, or provide design mitigation elements such as clerestory windows, enhanced landscaping, setbacks, and varied rooflines etc.
To fully comply with Plan Tucson and PEAP, the design of the proposed development must reflect sensitivity to the surrounding neighborhood condition and adjacent land uses. The use should also enhance the overall function and visual quality of the street, adjacent properties, and the community.
Key comments are as follows:
• R-2 zoning not supported
• Provide design elements to mitigate any negative impact from two-story to one-story units
• Consider Flexible Lot Development (FLD) per UDC Section 8.7.3.
Key process steps with the rezoning include:
1. Hold required neighborhood meeting
2. Rezoning application to include:
• Prepare a Design Compatibility Report (DCR), which discusses Land Use Compatibility, Design Compatibility, Drainage/Grading/Vegetation/Screening/Heat Island Mitigation, Road Improvements/Vehicular Access/Circulation, and Geotechnical Analysis;
• And prepare a Preliminary Development Plan (PDP) – including, but not limited to, calling out project density, required parking, building setbacks, and building heights per the UDC.
Rezoning process steps are:
1. Hold a Neighborhood Meeting as outlined in Section 3.2.2. of the Unified Development Code. For Rezoning Applications a single neighborhood meeting shall be held. The mailed notice must be mailed at least ten (10) days prior to the date of the meeting and sent by first class mail to property owners within 400 feet of the property, registered neighborhood associations within one (1) mile of proposal, and the Council Ward offices where the project is located. In addition, the following applies:
a. The meeting shall occur not more than 60 days prior to the date of the submittal of the application.
b. Documentation of the offer to meet and a summary of the meeting must be submitted with the application.
c. The meeting must be held at or near the subject site.
d. Mailing labels for neighborhood notice will need to be acquired from PDSD.
e. Please reach out to Ward 2 Office before the neighborhood meeting.
2. Project will need to be scheduled for a Zoning Examiner (ZE) Public Hearing as outlined in Section 3.5.3 of the Unified Development Code.
3. Mayor and Council Actions will need to occur as outlined in Section 3.5.3 of the Unified Development Code.
Fire New Construction REVIEW COMPLETED TP-PRE-0625-00122 • Pre-Application Conference Review v1 • 9220 E ROSEWOOD ST TUCSON, AZ 85710:
Based on the information provided, TFD has no comments at this time.
Questions: patricia.shelton@tucsonaz.gov / 520.837.7082
Site Engineering REVIEW COMPLETED 1. A tentative/final plat will be required for the proposed development.
2. A drainage report will be required at time of tentative plat review to review drainage design and to show compliance with balance basin detention and first flush retention requirements.
3. A SWPPP will also be required at the time of the tentative plat review and submitted with the grading plan.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
Site Landscape REVIEW COMPLETED CDRC TRANSMITTAL
PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
REVIEWER: CHAD KELLER, RLA
SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION

PROJECT: REZONING TO ALLOW FOR THE DEVELOPMENT OF A NEW SINGLE-FAMILY SUBDIVISION
ACTIVITY NO: TP-PRE-0625-00122
ADDRESS: 9220 E ROSEWOOD ST
ZONING: SR – SUBURBAN RANCH RESIDENCE ZONE

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting.

The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by the Site Landscape and NPPO section to ensure compliance with the applicable UDC development criteria and Technical Standards.

SITE LANDSCAPE/NPPO COMMENTS:

1. Add a statement to the PDP with regard to protected native plants and mitigation. STANDARD SITE LANDSCAPE COMMENT: A NPPO or a NPPO Waiver is required per UDC 7.7. SEE UDC 7.7.3. APPLICABILITY; UDC 7.7.4 NPPO GENERAL PROVISIONS AND STANDARDS; UDC 7.7.4.C. PLAN APPROVAL PRIOR TO PERMITTING; UDC 7.7.4.D. PROFESSIONAL EXPERTISE 7.7.5.C.5.

2. There are allies and it appears that walls are present at the rear of most, or all of the adjacent residential properties. With this rezoning it is requested that some kind of planting screen be implemented along the east, west and south property lines. No interior landscape borders are required, but the additional screening will be an amenity for the property owners within the new subdivision.

3. A landscape plan is required. Preparation of the landscape plan shall adhere to UDC 7.6.4 and Administrative Manual 2-10.

4. A street landscape border is required along Rosewood St per UDC 7.6.4.C-2 and Table 7.6.4-1. See UDC 7.6.4.C for landscape border requirements. Subdivision of 8 or more lots along MS&R and non-MS&R requires a 10’ street landscape border.

5. A drip irrigation plan and details are required for all proposed landscape planting areas.

6. DTM review is required for all planting and irrigation in the ROW prior to the approval of the development package. Reach out to David Marhefka (david.marhefka@tucsonaz.gov) if necessary for this project.

7. All landscape plans shall incorporate water conserving design as defined in UDC Section 7.6.6, Use of Water, and as described in the Technical Standards Manual 5.01-5.11.

8. Depress landscape planting areas on site for rainwater harvesting.

Thank you.
Chad Keller, RLA
Landscape Architect
chad.keller@tucsonaz.gov
520.837.4923
Site Zoning REVIEW COMPLETED FROM: Ramiro Olivarez
PDSD Zoning Review
PROJECT: Pre-submittal meeting TP-PRE-0625-00122
Address: 9220 E ROSEWOOD ST
Existing Zone: SR
Proposed Zoning: R-2
Existing Use: SFR
Proposed Use: SUBDIVISION / FLEXIBLE LOT DEVELOPMENT

TRANSMITTAL DATE: July 03, 2025

SUBDIVISION / FLEXIBLE LOT DEVELOPMENT COMMENTS:
1. Comment: The Preliminary Development Package (DP) reference must significantly correspond with the DP when you are formally ready to submit with Administrative Manual 2-03.3.0.

2. Comment: The proposed development must comply with the City of Tucson Unified Development Code (UDC) Administrative Manual Chapter 2-06 – Development Package. Building permits can be submitted and reviewed concurrently with the development package but the building plans cannot be approved until the development package is approved and the building plans are reviewed for consistency.

3. Comment: Flexible Lot Development use is allowed in the R-2 zone with use specific standards 8.7.3.

4. Comment: R-2 FLD Dimensional Standards, UDC Table 8.7.3-1:

a. Development Alternatives A –
i. Site Coverage = 62%
ii. Allowable Density = 8.71
iii. Building Height (ft) = 25
b. Development Alternatives B –
i. Site Coverage = 75%
ii. Allowable Density = 22
iii. Building Height (ft) = 25

5. Comment: No minimum lot size
6. Comment: Functional Open Space Standards, Table 8.7.3-2:
a. Project Size for 5 acres or less
i. Functional Open Space Requirement is 13 Dwelling Units/Acre or more = 161 SF/unit

7. Comment: A homeowners’ association or management organization shall be established by the developer to be responsible for the ownership, permanent care, and maintenance of functional open space areas. (UDC 8.7.3.F.1.d.)

8. Comment: FLD projects five acres and less. Functional open space amenities should be configured as contiguous areas but may also be incorporated into the design of other elements on the site, such as detention/retention basins and buffers, in order to make those areas functional.

9. Comment: Functional open space shall be conveniently located to and usable by the maximum number of the residential units on the site. (UDC 8.7.3.F.2.c)

11. Comment: UDC 7.11.1. Detention and retention basins shall be:

A. Located in a common area, outside the boundaries of a residential lot;
B. Owned and maintained by the homeowners organization or management organization established by the developer;
C. Located within the perimeter wall, fence, or screening surrounding the FLD project site boundaries, if provided; and,
D. Designed and constructed in compliance with the Stormwater Detention/Retention Manual.


12. Comment: Parking shall comply with Section 7.4, Motor Vehicle and Bicycle Parking, applicable sections of Section 7.6.4.B, Landscaping and Screening in Vehicular Use Areas, and the Technical Standards Manual, applicable regulations related to accessibility, and the following criteria.

13. Comment: Circulation and Connectivity, The right-of-way and pavement widths for internal ways, common parking areas , streets , roads, or other means of vehicular circulation and for surface drainage serving the FLD shall be in accordance with Section 10-01.2.4, Parking Lanes, of the Technical Standards Manual and Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC. (UDC 8.7.3.J.1)

14. Comment: UDC 8.7.3.K. Perimeter Yards Along FLD Project Site Boundaries
1. Perimeter yards along FLD project site boundaries are required in accordance the site ’s underlying zone as provided in Section 6.3.4, Dimensional Standards and Exceptions Tables.
2. Street perimeter yards along FLD project site boundaries are required in accordance with Section 6.4.5.C, Street Perimeter Yards, unless special zoning requirements dictate a greater distance or different point of measurement.

UDC 8.7.3.L. Perimeter Yards on Interior Lots
1. The perimeter yard requirements of Section 6.3.4, Dimensional Standards and Exceptions Tables, may be reduced for setbacks along interior lot lines to the extent permitted by the City’s adopted Building Codes.
2. Along interior street lot lines , street perimeter yards are required, in accordance with Section 6.4.5.C, Street Perimeter Yards. The street setback may be administratively reduced by the PDSD Director based on a finding that the reduced setback enhances the architectural design or the vehicular circulation in the FLD and a transportation statement is approved by the City’s Traffic Engineering division. A street perimeter yard reduction request is considered for approval concurrent with the processing of the plat or site plan, whichever is applicable.
3. Along parking area access lanes (PAALs) , setbacks are required in accordance with Section 7.4.6.F.2, Setbacks from Access Lanes and PAALs.

15. Comment: Architectural Variation is required for projects with 20 or more single-family detached residential units except when residential units are on lots larger than 10,000 square feet or, where dwelling units are separated by 30 feet. (UDC 8.7.3.M.1.b(1))

16. Comment: An FLD shall be prepared, processed, and have a tentative and final plat or site plan , whichever is applicable, approved prior to issuance of a building permit with the following exception. Model homes may be authorized for construction prior to recordation of the final plat in accordance with Section 8.6.4, Permits for Model Homes. (UDC 8.7.3.P)


Standard R-2 SUBDIVISION COMMENTS:


17. Comment: In the R-2 zone the minimum lot size is 5,000 SF. UDC TABLE 6.3-4.A.

18. Comment: Maximum lot coverage for residential use is 70%. UDC TABLE 6.3-4.A.

19. Comment: The height maximum is 25 feet for multifamily residential use. UDC TABLE 6.3-4.A.

20. Comment: At the proposed average lot size, 6,300 Sq. Ft. 1 unit per lot is within the requirements.

21. Comment: Setbacks for a residential use adjacent to a residential zone is 6 feet or 2/3 (H) of the proposed exterior building wall, whichever is greater. UDC TABLE 6.3-4.A.

The front street perimeter yard is 20’ measured from the street property line. (UDC 6.4.5.C.1.a)

22. Comment: Ensure compliance with Table 7.4.4-1: Minimum Number of Motor Vehicle Spaces for Single- Family Dwelling; Mobile Home Dwellings is

a. 2 spaces per dwelling unit plus visitor parking required at a ratio of 0.25 space per unit. Exception. Residential development in the R-1 zone must comply with Section 4.9.7.B.7

23. Comment: The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions, please contact me at Ramiro.Olivarez@tucsonaz.gov
Traffic Engineering Review REVIEW COMPLETED Per the ITE Trip Generation Manual, a 26 home subdivision is anticipated to generate about 22 AM peak hour trips and 28 PM peak hour trips. This amount of traffic can be accommodated for by the surrounding roadway network. No comments or concerns from DTM Traffic Engineering Division.