| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Fire New Construction | REVIEW COMPLETED | TP-PRE-0624-00145 • Pre-Application Conference Review v1 • 839 W CONGRESS ST TUCSON, AZ 85745: Based on the information provided, TFD has no comments at this time. Questions: patricia.shelton@tucsonaz.gov / 520.837.7082 |
|||
| ROW Engineering Review | REVIEW COMPLETED | TP-PRE-0624-00145 (839 W CONGRESS ST TUCSON, AZ 85745) Comments: 1. No comments. Faffs Riederer Faffs.Riederer@tucsonaz.gov |
|||
| Site Engineering | REVIEW COMPLETED | Tucson codes and ordinances can be found online at: https://codelibrary.amlegal.com/codes/tucson/latest/overview The Design Standards for Stormwater Detention and Retention (DSSDR) manual can be found online at: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf 1. Maximize water harvesting by depressing landscape areas 6-9 inches and using curb cuts and flush curbs where feasible. 2. Provide the area of the new pavement in square feet. Provide calculations for the percent of expansion of impervious surfaces for the site. Per DSSDR 2.1.2: When expansion of existing development occurs, the first-flush runoff volume shall be calculated using: a. The total impervious and disturbed areas of the entire site, when more than 1 acre of new development is proposed and the new development is greater than 33% of the entire site. b. Only the impervious and disturbed area associated with the proposed expansion, when between 2,000 square feet and 1 acre of new development are proposed, or the new development is less than 33% of the entire site. Expansion area is cumulative over the life of the project. c. First-flush retention is not required when an expansion of less than 2,000 square feet is proposed. The 2,000-square-foot threshold is cumulative. 3. Please provide a hydrology report that proves that the existing storm drain has the capacity to handle the additional runoff from the new pavement for the 100-year storm event. Mike Ortiz michael.ortiz@tucsonaz.gov |
|||
| Site Landscape | REVIEW COMPLETED | CDRC TRANSMITTAL PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, RLA PDSD LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: PARKING LOT EXPANSION FOR EL RIO HEALTH CENTER ACTIVITY NO: TP-PRE-0624-00145 ADDRESS/PARCEL: 839 W CONGRESS ST / 11621302C ZONING: R-2 RESIDENCE ZONE This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to ensure compliance with the applicable UDC development criteria and Technical Standards. SITE LANDSCAPE/NPPO COMMENTS: 1. An NPPO or an NPPO waiver is required per UDC 7.7.3-B. A Native Plant Preservation Plan, Section 7.7.4, must be submitted and approved or a request for an exception from the Native Plant Preservation requirements shall be approved in accordance with Sections 7.7.3.D.3 & .4 of the UDC and Administrative Manual Section 2-11.0.0 prior to Grading Plan approval. PDSD will provide the applicant with the NPPO Waiver form upon request. 2. Provide the required number of trees in all vehicular parking areas (1 tree to 4 parking spaces) per UDC 7.6.4.B.1. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a. 3. If the required number of trees and vegetative ground cover do not meet the UDC requirements for interior landscape borders along on the north and south boundaries, then update the interior landscape borders to meet the standards per UDC 7.6.4.C-2 and Table 7.6.4-1. See UDC 7.6.4.C for landscape border requirements. 4. If the required number of trees and vegetative ground cover do not meet the UDC requirements for street landscape borders along Melwood Av, then update the street landscape border to meet the standards per UDC 7.6.4.C-2 and Table 7.6.4-1. See UDC 7.6.4.C for landscape border requirements. 5. All landscape plans shall incorporate water conserving design as defined in UDC Section 7.6.6, Use of Water, and as described in the Technical Standards Manual 5.01-5.11. 6. Depress new landscape areas within the parking lot 6 to 9 inches to maximize rainwater harvesting. If you have any questions about these comments, I can be reached at chad.keller@tucsonaz.gov |
|||
| Site Zoning | REVIEW COMPLETED | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Loran Shamis; Project Manager PROJECT: TP-PRE-0624-00145 Address: 839 W CONGRESS ST Parcel(s): 11621302C Zoning: R-2, C-3 Existing Use: Medical Service, outpatient, Community Garden Proposed Use: Medical Services, outpatient, Parking Lot expansion TRANSMITTAL DATE: June 27, 2024 COMMENTS: 1. The proposed development must comply with Administrative Manual 2-06 – Development Package. 2. The site is zoned R-2 and Medical service, excluding blood center, was permitted through a Board of Adjustment Variance C10-09-14. 3. There are multiple Variances associated with this development. Refer to DP20-0027 for the case numbers and include those numbers and descriptions on this submittal. 4. The required standard parking space dimensions are 8.5 feet wide by 18 feet long (UDC 7.4.6.D). Provide a detail of the parking spaces in the development package. 5. Provide a pedestrian circulation path that connects all areas of development and to any adjacent street frontage. The path must be ADA accessible and a minimum of 4’ wide (TSM 7-01). 6. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at Loran.Shamis@tucsonaz.gov. |
|||
| TW New Area Development | REVIEW COMPLETED | TP-PRE-0624-00145 - Pre-Application Conference Review v1 – 839 W CONGRESS ST Tucson Water has no objections to the proposed development and offers the following comments for your convenience: 1. There is an existing 5/8 inch irrigation meter on this property. If the meter needs to be relocated please contact New Services at TW_Common@tucsonaz.gov. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Michael Asbury, Engineering Associate Tucson Water, New Development Section 201 N. Stone Avenue, #2 Flr. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2202 michael.asbury@tucsonaz.gov |