Design Review | REVIEW COMPLETED | The property is within the boundaries of the Grant Road Investment District (GRID), Fontana Center District. If the GRID is going to be used as a tool for redevelopment, please send me at email ASAP to maria.gayosso@tucsonaz.gov, so we can include the Design Professional in this presubmittal meeting. Here's a link to the GRID's handout: https://www.tucsonaz.gov/files/sharedassets/public/city-services/planning-development-services/documents/grid_handout.pdf , and here's a link to the GRID document: https://www.tucsonaz.gov/files/sharedassets/public/city-services/planning-development-services/documents/ordinance_11581_and_exhibit_a.pdf . Thanks. | |||
Fire New Construction | REVIEW COMPLETED | TP-PRE-0623-00256 • Pre-Application Conference Review v1 • 355 E SAHUARO ST TUCSON, AZ 85705: Based on the information provided, TFD has the following comments: 1. Units classified as an R-2 per 2018 IBC, will require fire sprinklers in accordance with 2018 IFC, 903.3. 2. Gate width to be minimum 20’-0” in accordance with 2018 IFC, D103.5 3. Knox key switch/box in accordance with 2018 IFC, 506 Questions: patricia.shelton@tucsonaz.gov / 520.837.7082 |
|||
Site Engineering | REVIEW COMPLETED | Tucson codes and ordinances can be found online at https://codelibrary.amlegal.com/codes/tucson/latest/overview The Stormwater Retention-Detention Manual can be found online at https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf 1. A lot combination will be required prior to development. 2. Balanced basin detention and first flush retention is required. 3. Maximize water harvesting to all landscaped areas through the use of curb cuts and flush curbs. 4. A waste enclosure compliant with TSM 8-01 is required. 5. Provide pedestrian circulation to the proposed solid waste location and out to the sidewalk along the street frontage. 6. A back-up spur is compliant with UDC 7.4.6 F is required for parking spaces 12 and 13. 7. 1. From recent clarification from Environmental Services per TSM section 8, although recycling service isn’t required the site needs to provide at minimum the enclosure space for both solid waste and recycling. A single enclosure won’t be sufficient and a double enclosure or additional single enclosures will be needed to meet this requirement. It is also important to point out per TSM section 8-01.4.I - required parking may be reduced for existing development when solid waste and recycling enclosures are provided. Lianne Evans lianne.evans@tucsonaz.gov |
|||
Site Landscape | REVIEW COMPLETED | CDRC TRANSMITTAL PROJECT: SAHUARO APTS ACTIVITY NO. TP-PRE-0623-00256 ADDRESS/PARCEL: 355 & 365 E SAHUARO ST/ 115-01-151C & 115-01-1500 ZONING: R-2 This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to assure compliance with the applicable UDC development criteria and Technical Standards. COMMENTS: 1. There must be an NPPO waiver due to the existing nature of the site. An NPPO is required per UDC 7.7.3-B. A Native Plant Preservation Plan, Section 7.7.4, is required to be submitted or approved or a request for an exception from the Native Plant Preservation requirements approved in accordance with Sections 7.7.3.D.3 & .4 of the UDC and Admin. Manual Section 2-11.0.0 prior to Grading Plan approval. 2. A landscape plan is required per 7.6.2.B.1-b. The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development to submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4 and Administrative Manual 2-10. 3. Ensure the required number of trees is in all vehicular parking areas (1 tree: 4 parking spaces) per UDC 7.6.4.B.1. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a. This includes the parking area on the east side of the site. 4. There will need to be a street landscape border on E Sahuaro St per UDC 7.6.4.C-2 and Table 7.6.4-1. See UDC 7.6.4.C for landscape border requirements. 5. There will need to be an interior landscape border on the North side of the site per UDC 7.6.4.C-2 and Table 7.6.4-1. due to the difference in zoning between the parcels. See UDC 7.6.4.C for landscape border requirements. 6. While Landscape/NPPO recognizes that the drawings presented are conceptual, please note that the City of Tucson instituted an ornamental turf ban, which all of the green space located on the presented drawings is. Please ensure that this is not part of your submittal, otherwise it will be rejected outright. 7. See Engineering notes for Retention/Detention. 8. All landscape plans shall incorporate water conserving design as defined in UDC Section 7.6.6, Use of Water, and as described in the Technical Standards Manual 5.01-5.11. 9. The Landscape Plan should match the Commercial Rainwater Harvesting Plan as well as the Grading Plan. Landscape plan should have spot elevations in the detention/retention areas as well as in all water harvesting areas in the Landscape Plan. 10. Maximize the rainwater harvesting across the site into the landscape areas, including but not limited to the street landscape borders as well as the tree wells for the required trees for the parking lot. 11. A Commercial Rainwater Harvesting plan is required per UDC Technical Standards Manual – Section 4-01.3.0. and Section 5-01.0.0 Landscaping and Screening. Adherence to the Low Impact Development Standards outlined in Section 5 of the PCRFCD Design Standards for Stormwater Detention and Retention is required and shall work in conjunction with the Commercial Rainwater Harvesting design. Using Low Impact Development design and water harvesting provides critical basin detention and first flush retention for all new development and impervious area. The newly adopted Detention/Retention Manual can be found: https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-final-201406-manual.pdf With CoT edits to the manual are found at: https://www.tucsonaz.gov/files/pdsd/codes/Detention_Retention_Manual_Tech_Standards_Amemdments.pdf 12. The Commercial Rainwater Harvesting Plan must utilize the Site Water Budget (located here: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Water-Energy-Conservation) See TSM 4-01.0.0 Exhibit A. If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov or 520-837-4988 |
|||
Site Zoning | REVIEW COMPLETED | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Loran Shamis; Lead Planner PROJECT: Thursday Pre-submittal meeting – TP-PRE-0623-00256 Address: 355 and 365 E Sahuaro St Parcel(s): 11501151C and 115011500 Zoning: R-2 Overlay Zoning: Grant Road Urban Overlay District – Fontana Center Existing Use: Vacant Proposed Use: Multifamily development TRANSMITTAL DATE: July 20, 2023 COMMENTS: 1. The proposed development must comply with Administrative Manual 2-06 – Development Package. 2. The site is zoned R-2 and the use is multifamily development which is permitted subject to use specific standards 4.9.7.B.6, .9, & .10. 3. The site is within the optional Grant Road Urban Overlay District and some of the standards in the underlying zoning can be modified by opting into overlay district. Contact Maria Gayosso for more information - maria.gayosso@tucsonaz.gov. 4. A lot combination will be required to be processed through Pima County Assessors - https://www.asr.pima.gov/Downloads/Forms/ComboRequest.pdf 5. The maximum residential density is 15 dwelling units per acre. The site plan states the site is 0.86 acres which permits 12 dwelling units. 6. The setbacks are as follows: a. West, North, East (nonresidential adjacent to residential and nonresidential zones) – the greater of 10’ or ¾ the height of the proposed structure wall measured to the property line. b. South (street perimeter yard) – 20’ from the existing or future property line. 7. The vehicle parking ratio is 2.25 spaces per dwelling unit, required number of vehicle parking spaces is 27 spaces with 2 ADA compliant parking spaces and at least one should be van accessible. See UDC 7.4.6 Motor Vehicle Design Criteria. 8. 10% of the required parking must be EV ready and 20% EV capable. EV ready is A parking space within 6 feet of a suitable circuit termination point, and EV Capable is conduit is to 'future proof' for future EV charging at a site. See UDC 7.4.12. for EV Parking Design Criteria. 9. The short-term bicycle parking ratio is 0.10 spaces per bedroom, the long-term bicycle parking ratio is 0.5 per bedroom. The short-term bicycle parking must be within 50’ of the public entrance. The long-term bicycle parking requirement can be in the unit. See UDC 7.4.9 Bicycle Parking Design Criteria. 10. The maximum permitted height is 25’. 11. Provide a pedestrian circulation path within the site that complies with Technical Standards Manual 7-01. The path should be a minimum of 4’. 12. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at Loran.Shamis@tucsonaz.gov. |
|||
Traffic Engineering Review | REVIEW COMPLETED | TP-PRE-0623-00256 355 E. Sahuaro St. Comments: 1. Existing curb may remain if it is within tolerance of current standards. 2. New concrete Driveway Apron per P.A.G. standard 206. 3. New 5’ wide sidewalk per P.A.G. standard 200. 4. At least one sidewalk is required to connect the onsite circulation path to sidewalk in the ROW. 5. Where adjoining sidewalk from the property ties to sidewalk along the ROW frontage, a 60” X 60” ADA landing is required. Landings shall be 60” X 60” and not to exceed a 2% cross slope in all directions. 6. 3’ minimum buffer between curb and sidewalk, unless ROW is limited. David Stiffey DTM Project Coordinator David.Stiffey@tucsonaz.gov |
|||
TW New Area Development | REVIEW COMPLETED | TP-PRE-0623-00256 - Pre-Application Conference Review v1 – 355 E SAHUARO ST 1. Based on the information provided, Tucson Water has no objections to, or comments on, the proposed development. 2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |