Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: TP-PRE-0623-00240
Parcel: 11918030F

Address:
1202 W AJO WY

Review Status: Approved

Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1

Plan Number - TP-PRE-0623-00240
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
Fire New Construction REVIEW COMPLETED TP-PRE-0623-00240 • Pre-Application Conference Review v1 • 1202 W AJO WY TUCSON, AZ 85713: Based on the information provided, TFD has no comments at this time. Questions: patricia.shelton@tucsonaz.gov / 520.837.7082
Site Engineering REVIEW COMPLETED Tucson codes and ordinances can be found online at https://codelibrary.amlegal.com/codes/tucson/latest/overview
The Stormwater Retention-Detention Manual can be found online at https://www.tucsonaz.gov/files/pdsd/updated-retention-detention-manual/updated-retention-detention-manual.pdf

1. Balanced basin detention is required on this site.
2. First flush retention is required on this site.
3. Maximize water harvesting to landscaped areas through use of curb cuts and flush curbs.
4. The City of Tucson encourages Low Impact Design (LID) practices for storm water management as defined by the Stormwater Retention Detention Manual. These standards discourage the use of large retention/detention basins and encourage the use of smaller basins and planted bioretention basins throughout the site. The goal is to achieve the same volume of detention while attempting to mimic natural hydrologic processes and increase land available for development.Pima County's LID software (https://www.pima.gov/1727/Software) is useful as a tool to show compliance with these standards.
5. If a lot split is proposed, a cross-use agreement will be required for shared use of the waste enclosure.

Lianne Evans
lianne.evans@tucsonaz.gov
Site Landscape REVIEW COMPLETED CDRC TRANSMITTAL
PROJECT: RESTAURANT/RETAIL
ACTIVITY NO. TP-PRE-0623-00240
ADDRESS/PARCEL: 1202 W AJO WY/119-18-030F
ZONING: C-1

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.

The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to assure compliance with the applicable UDC development criteria and Technical Standards.

COMMENTS:
1. There must be a NPPO or NPPO waiver. An NPPO is required per UDC 7.7.3-B. A Native Plant Preservation Plan, Section 7.7.4, is required to be submitted or approved or a request for an exception from the Native Plant Preservation requirements approved in accordance with Sections 7.7.3.D.3 & .4 of the UDC and Admin. Manual Section 2-11.0.0 prior to Grading Plan approval.
2. A landscape plan is required per 7.6.2.B.1-b. The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development to submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4 and Administrative Manual 2-10.
3. Ensure the required number of trees is in all vehicular parking areas (1 tree: 4 parking spaces) per UDC 7.6.4.B.1. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a.
4. There will need to be a street landscape border on Cottonwood Ln & W Ajo Wy per UDC 7.6.4.C-2 and Table 7.6.4-1. See UDC 7.6.4.C for landscape border requirements.
5. There will need to be a interior landscape border on the north & east sides of the site per UDC 7.6.4.C-2 and Table 7.6.4-1. See UDC 7.6.4.C for landscape border requirements.
6. See Engineering notes for Retention/Detention.
7. All landscape plans shall incorporate water conserving design as defined in UDC Section 7.6.6, Use of Water, and as described in the Technical Standards Manual 5.01-5.11.
8. The Landscape Plan should match the Commercial Rainwater Harvesting Plan as well as the Grading Plan. Landscape plan should have spot elevations in the detention/retention areas as well as in all water harvesting areas in the Landscape Plan.
9. Maximize the rainwater harvesting across the site into the landscape areas, including but not limited to the street landscape borders as well as the tree wells for the required trees for the parking lot.
10. Commercial Rainwater Harvesting plan is required per UDC Technical Standards Manual – Section 4-01.3.0. and Section 5-01.0.0 Landscaping and Screening. Adherence to the Low Impact Development Standards outlined in Section 5 of the PCRFCD Design Standards for Stormwater Detention and Retention is required and shall work in conjunction with the Commercial Rainwater Harvesting design. Using Low Impact Development design and water harvesting provides critical basin detention and first flush retention for all new development and impervious area. The newly adopted Detention/Retention Manual can be found: https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-final-201406-manual.pdf

With CoT edits to the manual are found at: https://www.tucsonaz.gov/files/pdsd/codes/Detention_Retention_Manual_Tech_Standards_Amemdments.pdf

If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov or 520-837-4988
Site Zoning REVIEW COMPLETED CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review
FROM: Nicholas Martell, Principal Planner
PROJECT: Thursday Pre-submittal meeting - TP-PRE-0623-00240
Address: Parcel 11918030F
Zoning: C-1
Existing Use: Vacant
Proposed Use: Commercial-Food Service, Retail-Food and Beverage Sales
TRANSMITTAL DATE: June 29, 2023

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. Commercial-Food Service is an allowed use in the C-1 sone, subject to 4.9.4.M.1 & 5 and 4.9.13.O
3. Retail-Food and Beverage Sales is an allowed use in the C-1 zone, subject to 4.9.13.O
4. It is noted that the applicant is attempting to use the Food and Beverage sales use, as opposed to the Food Service use. Approval of the concept is pending Zoning Administrator review and determination.
5. Parking is calculated as follows (Table 7.4.4-1 UDC);
a. Food Service: 1 space per 100 sq. ft. GFA and outdoor seating areas
b. Food and Beverage Sales: 1 space per 300 sq. ft
5. Non-residential uses adjacent to non-residential zones have 0’ setbacks adjacent to interior lots. Non-residential uses adjacent to residential zones require a 1½(H) setback.
6. For nonresidential and multifamily development abutting an Arterial or Collector Street the minimum required street perimeter yard is ten feet, as measured from the existing or future property line as determined by the adopted Major Streets and Routes Plan , whichever is greater.
b. For nonresidential and multifamily development abutting a Local Street : the minimum required street perimeter yard is 20 feet, as measured from the street property line (6.4.5.)
7. The maximum building height for a commercial use in the C-1 zone is 30’ (6.3-4.A UDC)
8. Ensure access standards found in section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met.
9. If a land split is proposed, a cross access agreement will be required to approve the Development Package as shown on the site plan.
10. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.
If you have any questions about this transmittal, contact me at Nicholas.Martell@tucsonaz.gov
Traffic Engineering Review REVIEW COMPLETED TP-PRE-0623-00240
1202 W. Ajo Way

Comments:
1. Any existing curb, sidewalk or curb access ramps which are non-compliant will be reconstructed to meet current standards.
2. Close unused curb cuts with P.A.G. standard 209 Concrete Curb and P.A.G. standard 200 Concrete Sidewalk.
3. New concrete Driveway Apron per P.A.G. standard 206.
4. Modify existing Driveway Apron per P.A.G standard 206.
5. At least one sidewalk is required to connect the onsite circulation path to sidewalk in the ROW.
6. Where adjoining sidewalk from the property ties to sidewalk along the ROW frontage, a 60” X 60” ADA landing is required. Landings shall be 60” X 60” and not to exceed a 2% cross slope in all directions.
7. Protect in place existing streetlights.
8. Protect in place existing catch basins.

David Stiffey
DTM Project Coordinator
David.Stiffey@tucsonaz.gov
TW New Area Development REVIEW COMPLETED TP-PRE-0623-00240 - Pre-Application Conference Review v1 – 1202 W AJO WY

1. Based on the information provided, Tucson Water has no objections to the proposed development and offers the following comments for your convenience:

2. At this time. I personally do not expect the existing water easement on the property will ever be needed. Please submit a written request to Ms. Kathryn Gerber, Tucson Water’s Planning Section’s Engineering Manager asking permission to proceed with the release of this existing water easement. And if cannot be released, whether trees and the drive thru line may be located within this easement. Ms. Gerber’s e-mail address is kathryn.gerber@tucsonaz.gov.

3. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
Zoning Administration REVIEW COMPLETED Staff recommends the landscape and screening modifications requests be combined in one application for the Board of Adjustment Variance process. A full review of the DP will be required prior to applying for the variances. If you have questions, you can email me at Mark.Castro@tucsonaz.gov