Plan Review Detail
Review Status: Approved
Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1
Plan Number - TP-PRE-0623-00235
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Fire New Construction | REVIEW COMPLETED | TP-PRE-0623-00235 • Pre-Application Conference Review v1 •2481 N FREMONT AV TUCSON, AZ 85719: Based on the information provided, TFD has no comments at this time. Questions: patricia.shelton@tucsonaz.gov / 520.837.7082 | |||
| Site Engineering | REVIEW COMPLETED | 1. Maximize Water Harvesting 2. A sidewalk will be required along Fremont and Water St 3. DTM ROW approval required if driveway exceeds UDC 25-38 - maximum residential curb cut width is 20 feet. 4. Ensure pedestrian circulation to Water, Fremont, parking, and any other common areas. Joshua Garcia joshua.garcia@tucsonaz.gov |
|||
| Site Landscape | REVIEW COMPLETED | CDRC TRANSMITTAL PROJECT: ADU NEXT TO DUPLEX ACTIVITY NO. TP-PRE-0623-000235 ADDRESS/PARCEL: 2481 N FREMONT/113-09-3210 ZONING: R-2 This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to assure compliance with the applicable UDC development criteria and Technical Standards. COMMENTS: 1. There must be a NPPO or NPPO waiver. An NPPO is required per UDC 7.7.3-B. A Native Plant Preservation Plan, Section 7.7.4, is required to be submitted or approved or a request for an exception from the Native Plant Preservation requirements approved in accordance with Sections 7.7.3.D.3 & .4 of the UDC and Admin. Manual Section 2-11.0.0 prior to Grading Plan approval. 2. Ensure the required number of trees is in all vehicular parking areas (1 tree: 4 parking spaces) per UDC 7.6.4.B.1. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a. 3. See Engineering notes for Retention/Detention. 4. All landscape plans shall incorporate water conserving design as defined in UDC Section 7.6.6, Use of Water, and as described in the Technical Standards Manual 5.01-5.11. 5. Maximize the rainwater harvesting across the site into the landscape areas, including but not limited to the street landscape borders as well as the tree wells for the required trees for the parking lot. If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov or 520-837-4988 |
|||
| Site Zoning | REVIEW COMPLETED | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Wyatt Berger, Lead Planner PROJECT: Thursday Pre-submittal meeting – TP-PRE-0623-00235 Address: 2841 North Fremont Avenue Parcel(s): 113-09-3210 Zoning: R-2 “residential” Existing Use: Duplex Proposed Use: Multifamily development (new ADU) TRANSMITTAL DATE: June 21, 2023 COMMENTS: 1. Development must comply with Administrative Manual Section 2-06.0.0: Development Package (Tentative Plats and Site Plans). Building permits may be applied for concurrently with the development package; however, the development package must be approved and issued prior to approval and issuance of the associated building permits. 2. An Accessory Dwelling Unit (ADU) is a permitted use in the R-2 zone, subject to use-specific standards 4.9.7.B.6, .9, and .10, and 6.6.3. 3. Three on-site motor vehicle parking spaces are required for the development. The required parking space for the ADU may be waived if the site is located within 1,320 feet of a transit stop or an enhanced bike route as listed in the Bike Boulevard Master Plan. 4. Ensure that the proposed ADU is developed with a high albedo level (>60 SRI) or other cool roof technology per the ICC Green Construction Code (UDC 6.6.3.B.3). 5. While the development shall adhere to UDC 7.4.6 Motor Vehicle Use Area Design Criteria, the surfacing requirements of UDC 7.4.6.I are exempt. A street or alley may be utilized for access and maneuvering (UDC 7.4.6.K.1.a). 6. Per UDC Table 6.3-2.A, when a nonresidential use is adjacent to a residential zone, the required interior perimeter yard setbacks are ten feet or ¾ the height of the proposed exterior building wall, whichever is greater, measured from the property line. A Design Development Option (DDO) in accordance with UDC 3.11.1 may allow setbacks to be reduced up to one foot from the property line. Contact me if you have questions about the DDO process. 7. Lot coverage shall not exceed 75% (UDC Table 6.3-2.A). 8. Two short-term and two long-term bicycle parking spaces are required for the development (UDC Table 7.4.8-1). Bicycle parking shall adhere to UDC 7.4.9. 9. Ensure that one of the required motor vehicle parking spaces is “EV Capable” (UDC Table 7.4.11-1). 10. Ensure compliance with Technical Standards Manual Section 7-01.4.3. All sidewalks must be a minimum of four feet wide and installed to avoid any obstruction which decreases the minimum width to less than four feet. 11. Ensure access standards found in Section 7.8 of the UDC and Sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met. 12. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
|||
| Traffic Engineering Review | REVIEW COMPLETED | No Comments David Stiffey David.Stiffey@tucsonaz.gov |
|||
| TW New Area Development | REVIEW COMPLETED | TP-PRE-0623-00235 - Pre-Application Conference Review v1 – 2481 N FREMONT AV 1. Tucson Water has no objections to the proposed development and offers the following comments for your convenience. 2. There is no existing public water main in Water St. that can serve the proposed accessory dwelling unit. 3. The existing duplex on the property obtains its water from a single ⅝” water meter and ¾” water service line connected to the existing 6” public water main in Fremont Avenue. 4. The proposed accessory dwelling unit will need to obtain its water either by connecting to the the existing 6” public water main in Fremont Avenue, or by connecting to the private plumbing of the existing duplex. The latter option is acceptable if and only if the lot will never be split. 5. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |