Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: TP-PRE-0623-00228
Parcel: 141185840

Review Status: Approved

Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1

Plan Number - TP-PRE-0623-00228
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
Fire New Construction REVIEW COMPLETED TP-PRE-0623-00228 - Pre-Application Conference Review v1 - 10051 E OLD VAIL RD TUCSON, AZ 85747: Based on the information provided, TFD has no comments at this time. Questions: patricia.shelton@tucsonaz.gov / 520.837.7082
Site Engineering REVIEW COMPLETED 1. Ensure detention requirements follow the Old Vail Drainage Plan
2. First flush retention regulations are required. Please refer to the updated retention/detention manual at: https://www.tucsonaz.gov/files/pdsd/updated-retention-detention-manual/updated-retention-detention-manual.pdf With amendments listed at: https://www.tucsonaz.gov/files/pdsd/codes/Detention_Retention_Manual_Tech_Standards_Amemdments.pdf
3. Maximize water harvesting into any landscaping through the use of curb cuts, scuppers, and flush curbs
4. Ensure sufficient vehicle wheel stops or sidewalk width to maintain a 4' pedestrian path with a 2.5' vehicle overhang in sidewalk adjacent to parking spots (TSM 7-01.4)
5. From recent clarification from Environmental Services, per TSM section 8, although recycling service isn’t required the site needs to provide at minimum the enclosure space for both solid waste and recycling. So a single enclosure won’t be sufficient and a double enclosure or an additional single enclosure will be needed to meet this requirement. It is also important to point out per TSM section 8-01.4.I - required parking may be reduced for existing development when solid waste and recycle enclosures are provided.
6. Ensure waste design and maneuverability per TSM 8-01
Joshua Garcia
joshua.garcia@tucsonaz.gov
Site Landscape REVIEW COMPLETED CDRC TRANSMITTAL
PROJECT: KFC
ACTIVITY NO. TP-PRE-0623-00228
ADDRESS/PARCEL: 10051 E OLD VAIL RD/ 141-18-5840
ZONING: I-1

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.
The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to assure compliance with the applicable UDC development criteria and Technical Standards.

COMMENTS:
1. Due to the existing nature of the site and the small building envelope of the actual site (KFC does not own the parking areas, just the building envelope of the actual restaurant), landscape has no concerns or questions about this site.
2. Maximize the rainwater harvesting (for first flush retention) across the site into the landscape areas, including but not limited to the street landscape borders as well as the tree wells for the required trees for the parking lot.

If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov or 520-837-4988
Site Zoning REVIEW COMPLETED CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review
FROM: Paul Camarena, Planner
PROJECT: Thursday Pre-submittal meeting – TP-PRE-0623-00228
Address: 10051 E OLD VAIL RD
Parcel(s): 141185840
Zoning: I-1
Existing Use: Vacant
Proposed Use: Food Service
TRANSMITTAL DATE: 6/21/2023

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. This site is subject to DP14-0248. The proposed use is Food service which is permitted in the I-1 zone. Base on DP14-0284 this lot has been approved as a retail use, since this lot is going to be a food service use a revision to the approved DP will be required.
3. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions, please contact me at Paul.Camarena@tucsonaz.gov
Traffic Engineering Review REVIEW COMPLETED No Comments

David Stiffey

David.Stiffey@tucsonaz.gov
TW New Area Development REVIEW COMPLETED TP-PRE-0623-00228 - Pre-Application Conference Review v1 – 10051 E OLD VAIL RD

1. Tucson Water has no objections to the proposed development and offers the following comments for your convenience.

2. The water meter must be located within the public water easement created by Seq. No. 20112770309, and the existing 2” copper service line located between the water meter and the existing public water main is public, not private.

3. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov