Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Approved
Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1
Plan Number - TP-PRE-0524-00129
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
Fire New Construction | REVIEW COMPLETED | TP-PRE-0524-00129 • Pre-Application Conference Review v1 • 2020 W PRINCE RD TUCSON, AZ 85705: Based on the information provided, TFD has no comments at this time. Questions: patricia.shelton@tucsonaz.gov / 520.837.7082 |
|||
ROW Engineering Review | REVIEW COMPLETED | TP-PRE-0524-00129 2020 W. Prince Rd. Comments: 1. On Weymouth St, the first entrance to the property heading west from Runway, a. The existing curb and gutter needs to be checked for its condition. If it is cracked, or busted up, it’ll need to be replaced- through the width of the entrance only. b. The entrance width (width of the opening of the gate) will have to be paved from back of curb to property line. Paved with City Mix No.- with TR-22. (NOTE: Design an appropriate asphalt pavement structural section to accommodate large trucks.) 2. At the bend, where Weymouth turns north and becomes Melody Ln. There appears to be a new ingress/ egress entrance to the property. This will have the same requirements as the other entrance mentioned. a. The existing curb and gutter needs to be checked for its condition. If it is cracked, or busted up, it’ll need to be replaced- through the width of the entrance only. b. The entrance width (width of the opening of the gate) will have to be paved from back of curb to property line. Paved with City Mix No.- with TR-22. (NOTE: Design an appropriate asphalt pavement structural section to accommodate large trucks.) 3. Note: All of the rest of the “existing” ROW improvements are satisfactory. NO new sidewalk will be required. David Stiffey DTM Project Coordinator David.Stiffey@tucsonaz.gov |
|||
Site Engineering | REVIEW COMPLETED | The Design Standards for Stormwater Detention and Retention manual can be found online at https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf 1. Proposal of a pump requires compliance with all standards outlined in section 4.18 of the DSSDR. A drainage statement will be required that addresses all of the standards in section 4.18. Mike Ortiz michael.ortiz@tucsonaz.gov |
|||
Site Landscape | REVIEW COMPLETED | CDRC TRANSMITTAL PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, RLA PDSD LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: OWNER IS PROPOSING A PARTIAL CHANGE OF USE (RETAIL GOES TO STORAGE) AND PARTIAL DEMOLITION OF EXISTING BUILDING. THE PROJECT WOULD ALSO INTRODUCE MORE LOADING DOCKS AND TRUCK PARKING ACTIVITY NO: TP-PRE-0524-00129 ADDRESS/PARCEL: 2020 W PRINCE RD/ 10610005D ZONING: I-1 LIGHT INDUSTRIAL ZONE This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to ensure compliance with the applicable UDC development criteria and Technical Standards. SITE LANDSCAPE/NPPO COMMENTS: 1. Provide a landscape mitigation plan for the plants being removed due to the parking expansion. Mitigate the removed planter island plants at a 1:1 ratio. Recommended placement of the mitigation plant material is near the south border and truck parking area. 2. On the landscape mitigation plan, show supplemental drip irrigation to the new mitigation plants for plant establishment. 3. Site Landscape/NPPO have no other comments or concerns with this project. If you have any questions about these comments, I can be reached at chad.keller@tucsonaz.gov |
|||
Site Zoning | REVIEW COMPLETED | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Nicholas Martell, Principal Planner PROJECT: Thursday Pre-submittal meeting - TP-PRE-0524-00129 Address: 2020 W Prince, Parcel: 10610005D Zoning: I-1 Existing Use: Commercial Storage, Retail Trade, Administrative and Professional Office Proposed Use: Commercial Storage TRANSMITTAL DATE: June 13, 2024 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. A Commercial Storage use is allowed in the I-1 zone contingent on compliance with 4.9.10.A and 4.9.13.Q 3. Show bike parking per table 7.4.8-1 of the UDC 4. Ensure access standards found in section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met. 5. It does not appear that there will be an expansion of more than 25%. However, a change of use may initiate full code compliance. Per 7.5.3.D of the UDC. 6. Ensure the reduction of parking is in compliance with UDC 7.4.4-1 and 7.4.6 7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions about this transmittal, contact me at Nicholas.Martell@tucsonaz.gov |
|||
TW New Area Development | REVIEW COMPLETED | TP-PRE-0524-00129 - Pre-Application Conference Review v1 – 2020 W PRINCE RD Tucson Water offers the following comments for your convenience: 1. This project is not within Tucson Water service area. 2. Please contact the Flowing Wells Irrigation District with any water-related questions you may have about this project. The Flowing Wells Irrigation District may be contacted by filling out an online form at https://www.fwid.org/contact/ or by calling 520-887-4192. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |