Plan Number: TP-PRE-0425-00069
Parcel: 11302001H

Review Status: Approved

Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1

Plan Number - TP-PRE-0425-00069
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
Fire New Construction REVIEW COMPLETED TP-PRE-0425-00069 • Pre-Application Conference Review v1 • 3957 N MOUNTAIN AV TUCSON, AZ 85719:
Based on the information provided, TFD has the following comments:
1. Verify hydrant coverage. IFC 24, 507.5.1
Questions: patricia.shelton@tucsonaz.gov / 520.837.7082
ROW Engineering Review REVIEW COMPLETED Roger Road and Mountain Ave are both collectors on MS&R Map, existing ROW limits and future limits should be shown.
Curb and sidewalk required along Roger Rd.
Unused existing curb openings shall be closed.
Site Engineering REVIEW COMPLETED TP-PRE-0425-00069
3957 N MOUNTAIN AV

1. The N Mtn Ave Wash is on the east portion of the property. Please show the delineated floodplain on site plans. Depending on the location of the FP will determine FUP requirements.
2. Please include area of disturbance & cut/fill quantities on the plan set.
3. First flush retention and balanced basin detention compliant with sections 2 and 3 of the DSSDR will be required. A drainage report will be required to establish that these requirements are being met.
4. Show locations of roof downspouts. Stormwater from roof drains may not pass over sidewalks per TSM 7-01.4.3E.
5. Show that the interior road cross section is being met per TSM 10-01.9.0
6. Sidewalks should be in a common area & not on individual lots.



Chris Arrington
chris.arrington@tucsonaz.gov
Site Landscape REVIEW COMPLETED CDRC TRANSMITTAL
PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
REVIEWER: CHAD KELLER, RLA
SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION

PROJECT: FLEXIBLE LOT DEVELOPMENT (FLD)
ACTIVITY NO: TP-PRE-0425-00069
ADDRESS: 3957 N MOUNTAIN AV
ZONING: R-2 RESIDENCE ZONE
LAND USE: FLEXIBLE LOT DEVELOPMENT (RESIDENTIAL)

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting.

The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to ensure compliance with the applicable UDC development criteria and Technical Standards.

FLEXIBLE LOT DEVELOPMENT SITE LANDSCAPE COMMENTS:
1. See UDC 8.7.3.H -- LANDSCAPING, SCREENING AND WALL REQUIREMENTS:
1. FLD projects shall comply with Section 7.6, Landscaping and Screening Standards, except as otherwise provided by this section.
2. One canopy tree shall be provided for every 40 feet of pedestrian circulation systems, excluding crossings with streets, alleys, and driveways. If providing canopy trees every 40 feet is not achievable, the applicant shall:
a. Provide the equivalent number of trees that would be obtained using the 40-foot increment measure; and,
b. Distribute the trees within the FLD project site along pedestrian circulation systems and within functional open space areas.
3. Landscape plans shall incorporate water-conserving design as defined in Section 7.6.6, Use of Water, and as described in the Technical Standards Manual.
4. Water harvesting techniques shall be incorporated as part of the landscape design based on the Water Harvesting Guidance Manual prepared for the City of Tucson Transportation Department Stormwater Section.
5. Mechanical equipment, utility boxes, irrigation equipment and similar elements shall be screened from adjacent streets exterior to the project and from adjacent existing residential development. Screening shall be architecturally integrated with the overall design of the FLD.
6. If a perimeter wall is proposed along an existing public right-of-way, it shall be constructed of, or painted with, graffiti-resistant materials. The wall shall incorporate one or more of the following decorative materials:
a. Tile;
b. Stone;
c. Brick;
d. Adobe;
e. A textured material such as stucco or plaster; or,
f. Metal.

2. See UDC 8.7.3.F: OPEN SPACE REQUIREMENTS. See Table 8.7.3-2 for Functional Open Space Standards.

3. UDC 8.7.3.F.2 CONFIGURATION AND LOCATION OF FUNCTIONAL OPEN SPACE WITHIN AN FLD PROJECT ARE AS FOLLOWS:
a. FLD projects five acres and less. Functional open space amenities should be configured as contiguous areas but may also be incorporated into the design of other elements on the site, such as detention/retention basins and buffers, to make those areas functional.
b. FLD projects more than five acres. Functional open space may be divided into smaller areas if they are distributed throughout the project site and conveniently located for residents of the FLD project.
c. Functional open space shall be conveniently located to and usable by the maximum number of residential units on the site.
d. To the greatest extent possible, functional open space should not be comprised of remnant areas that are not usable by residents of the FLD project.
e. Where the project is located near a public preserve, or can provide connections to open space areas or areas of environmentally or culturally significant features, the open space shall be configured in a manner to preserve this connectivity

4. Depress Functional Open Space landscape planting areas 6 inches to maximize rainwater harvesting on site.

5. A NPPO or a NPPO Waiver is required per UDC 7.7.3-B. A Native Plant Preservation Plan, Section 7.7.4, must be submitted and approved or a request for an exception from the Native Plant Preservation requirements shall be approved in accordance with Sections 7.7.3.D.3 & .4 of the UDC and Administrative Manual Section 2-11.0.0 prior to Grading Plan approval. PDSD Landscape Architect will provide the applicant with the NPPO Waiver form upon request.

6. A landscape plan is required per UDC 7.6.2.B.1-b. The Unified Development Code requires all new development, or an expansion of greater than 25% of an existing development to submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4 and Administrative Manual 2-10.

7. The south parking area requires a 5’ masonry wall along the property line for the entire width of the parking area located on the property line. For more information on the location of the screen wall and landscape border requirements see UDC 7.6.5.C.

8. A street landscape border is required along E Roger Rd and along N Mountain Av per UDC 7.6.4.C-2 and Table 7.6.4-1. See UDC 7.6.4.C for landscape border requirements.

9. DTM approval is required for all planting and irrigation in the ROW. Contact David Marhefka with DTM if necessary for this project. (david.marhefka@tucsonaz.gov)

Thank you.
Chad Keller, RLA
Landscape Architect
chad.keller@tucsonaz.gov
Site Zoning REVIEW COMPLETED CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Loran Shamis; Principal Planner

PROJECT: TP-PRE-0425-00069
Address: 3957 N Mountain Av
Parcel(s): 11302001H
Zoning: R-2
Existing Use: Vacant
Proposed Use: Single Family Residential – FLD (Tentative and Final Plat)

TRANSMITTAL DATE: April 24, 2025

COMMENTS:
1. The proposed development must comply with Administrative Manual 2-06 – Development Package (Tentative Plat and Site Plans).
2. Per 8.7.3.P, an applicant shall hold a neighborhood meeting in accordance with Section 3.2.2.C.1.b prior to submitting a FLD application.
3. A Final Plat complying with AM 2-07 is required.
4. The site is zoned R-2 and the proposed use is single family residential which is permitted subject to use specific standards UDC 4.9.7.B.6, .9, & .10 (UDC Table 4.8-2).
5. Flexible Lot Development (FLD) shall comply with UDC Section 8.7.3.
6. The maximum site coverage for FLDs zoned R-2 is 62%. Site Coverage includes buildings, storage areas, and vehicular use areas (UDC Table 8.7.3-1).
7. The maximum height permitted in R-2 is 25’ (UDC Table 8.7.3-1).
8. The maximum permitted residential density is 8.71 units per acre. The site is 0.6 acres which allows 5 dwelling units. Consider exploring the Maximum Density Option for FLDs in accordance with UDC 8.7.3.C.3.b, or the Community Corridors Tool.
9. FLDs that are 5 acres or less with less than 13 dwelling units per acre, the minimum Functional Open Space requirement is 109 square feet per unit (UDC Table 8.7.3-2). Functional Open Space shall be for an active recreational, passive recreational or scenic purpose. It is unclear if the design of the FLD is meeting this standard.
10. Per UDC 6.4.5.C.1.d.3 – if accessed from the front or parallel to a street with an ADT of 140 or less, the distance from the back of curb to the garage or carport may be eight feet or less. The garage or carport must be setback a minimum of one foot from the property line.
11. The minimum setback along the project boundary to the west and south is the greater of 6’ or 2/3 the height of the proposed structure wall (UDC 8.7.3.K and UDC Table 6.3-2.A)
12. The minimum setback along the property boundary to the north and the east is 10’ from the property line (UDC 6.4.5.C)
13. The interior setbacks within the property boundary shall comply with building code (UDC 8.7.3.L).
14. The minimum parking requirement is 2.25 spaces per dwelling unit.
15. The sidewalk is required to be in the common area/right of way and the cross section of right of way shall comply with Technical Standards Manual Section 10-01-9.
16. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions, please contact me at Loran.Shamis@tucsonaz.gov.
TW New Area Development REVIEW COMPLETED TP-PRE-0425-00069 -Pre-Application Conference Review v1 – 3957 N MOUNTAIN

Tucson Water has no objections to the proposed development and offers the following comments for your convenience:

1. The property is currently being served by 4 active potable water meters and 1 irrigation meter from an 8 inch PVC water main from the far north side of Roger Rd.
2. Your development plan shows a total of 7 potable water meters on the north end of the property. Due to the 36in reclaimed water main and 30in sewer main along Roger Rd. we suggest that you consider tapping the 12 inch CA (Cement Asbestos) potable water main to the east along Mountain Ave. for the additional 3 water meters and leave the existing 4 meters where they are.
3. If any new domestic water, irrigation water, or fire water services are needed to serve this proposed development, please contact Tucson Water’s New Services Section by calling 520-791-5164 or by sending an email to TW_Common@tucsonaz.gov.

The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Michael Asbury, Senior Engineering Associate
Tucson Water, Planning and Engineering
310 W Alameda St
Tucson, AZ 85701
(520) 837-2202
michael.asbury@tucsonaz.gov