Review Date Reviewer's Name Type of Review Description Status Comments
Fire New Construction * NOT REQUIRED
Real Estate * PENDING ASSIGNMENT
Entitlements * REVIEW COMPLETED
ROW Engineering Review * REVIEW COMPLETED Unable to determine location of proposed site tower, please provide site plan for appoximate location.
Site Engineering * REVIEW COMPLETED 1. Site Engineering has no comments.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
Site Landscape * REVIEW COMPLETED PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
REVIEWER: CHAD KELLER, PLA
SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION

PROJECT: 70' WIRELESS COMMUNICATION FACILITY OF MONOPOLE DESIGN
ACTIVITY NO: TP-PRE-0326-00057
PARCEL: 13337002A
ZONING: RESIDENCE ZONE (R-1)
LAND USE: UTILITY SERVICE
03.17.2026

THE COMMENTS PROVIDED ARE PRELIMINARY AND ARE NOT TO BE ASSUMED AS A COMPLETE REVIEW OF THE PROPOSAL. DURING THE DEVELOPMENT PACKAGE REVIEW PROCESS, A FULL REVIEW WILL BE MADE BY THE SITE LANDSCAPE/NPPO REVIEW SECTION TO ENSURE COMPLIANCE WITH THE APPLICABLE CITY OF TUCSON UNIFIED DEVELOPMENT CODE, TECHNICAL STANDARDS MANUAL AND ADMINISTRATIVE MANUAL REQUIREMENTS FOR SITE LANDSCAPE, NATIVE PLANTS AND RAINWATER HARVESTING.

SITE LANDSCAPE/NPPO COMMENTS:

1. No comments or concerns with this proposed cell tower being placed on the existing City owned parcel No. 13337002A with the existing masonry wall surround.

Thank you.
Chad Keller, PLA
Landscape Architect
chad.keller@tucsonaz.gov
520.837.4923
Site Zoning * REVIEW COMPLETED CDRC Entitlements Pre-Application Transmittal
PDSD Zoning Review

FROM: Loran Shamis; Principal Planner

PROJECT: TP-PRE-0326-00057
Address: N/A
Parcel(s): 13337002A
Existing Zoning: R-1
Proposed Zoning: R-1
Overlay Zones: Environmental Resource Zone, Major Streets and Routes – Scenic Corridor
Existing Use: Vacant
Proposed Use: Commercial – Wireless Communications

TRANSMITTAL DATE: March 25, 2026

COMMENTS:
1. COMMENT: A development package that complies with Administrative Manual 2-06 is required for formal submittal.
2. COMMENT: The site is zoned R-1 and the proposed use is Commercial – Wireless Communication, limited to wireless communication towers and antennas, which is permitted through a Special Exception Procedure. Based on the proposed height of the structure, Mayor and Council Special Exception Procedure is required, subject to UDC 4.9.4.I.2, .3 &.8.
3. COMMENT: The site is located within the mandatory Major Streets and Routes Scenic Corridor Overlay. Per Use Specific Standard UDC 4.9.4.I.3.d, no new towers shall be permitted within 400 feet of a designated Scenic Route. It does not appear the proposal could comply with this requirement.
4. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions, please contact me at Loran.Shamis@tucsonaz.gov.
Traffic Engineering Review * REVIEW COMPLETED No comments
TW New Area Development * REVIEW COMPLETED This project cannot move forward without coordination with Tucson Water. This is a Tucson Water wellsite.
Contact Kathryn.Gerber@tucsonaz.gov of Tucson Water’s System Planning section to coordinate communication with water resources and Tucson Water Security.
The site is considered critical infrastructure: fencing, controlled access, and coordination with Tucson Water required. Telecom equipment must not compromise site security.
Separation / Clearance: Maintain safe distances from wellhead, electrical equipment, and chlorination or treatment facilities (if present). A new well may be drilled at this site. Tucson Water coordination will determine what facilities must remain and where new facilities are planned.
Additional considerations include:
No possible impact to water quality,
No hazardous materials or spill risks near wellhead,
Must not conflict with existing utility easements or underground infrastructure.
The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to Kathryn Gerber (Engineering Manager) at Kathryn.Gerber@tucsonaz.gov.