Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: TP-PRE-0226-00052
Parcel: 10511061A

Address:
4570 N ORACLE RD

Review Status: Approved

Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1

Plan Number - TP-PRE-0226-00052
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
Fire New Construction * REVIEW COMPLETED TP-PRE-0226-00052 • Pre-Application Conference Review v1 • 4570 N ORACLE RD TUCSON, AZ 85705:
Based on the information provided, TFD has no comments at this time.
Questions: patricia.shelton@tucsonaz.gov / 520.837.7082
ROW Engineering Review * REVIEW COMPLETED Oracle Rdis ADOT ROW. Traffic statement will be required for change of use.
Site Engineering * REVIEW COMPLETED Permit Activity Number: TP-PRE-0226-00052
Project: Loading Area Addition/Tenant Improvement
Location: 4570 N ORACLE RD
Review Date: 3/17/2026

*This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code.*

City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes

Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf

Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf

Site Engineering Review Comments:
1. Redesign vehicular use area to current standards if trucks do not require the full parking area for maneuverability.
2. Depressed loading areas are subject to strict drainage regulations to prevent flooding, particularly relevant in heavy commercial or industrial zones. If the loading dock areas are depressed, oil and sand separators will be required. If a pump is required to drain a depressed area it must conform to Tucson Water standard specs, Section 1204 and DSSDR Section 4.18. Please direct all pump discharge into the nearest landscaped areas.
3. Show the truck route from the ROW with offsite options included for maneuverability.
4. Possible sign for no local access/trucks only at the desired entrance of loading dock area.

This review is for Pre-Application purposes. Please be aware that additional comments may be forthcoming during submission process.

If you have any questions or concerns, please contact Joe Macaulay at Joe.Macaulay@tucsonaz.gov.
Site Landscape * REVIEW COMPLETED PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
REVIEWER: CHAD KELLER, PLA
SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION

PROJECT: TENANT IMPROVEMENTS OF AN EXISTING VACANT COMMERCIAL BUILDING
ACTIVITY NO: TP-PRE-0226-00052
ADDRESS: 4570 N ORACLE RD
ZONING: COMMERCIAL ZONE (C-3)
LAND USE: COMMERCIAL
03.16.2026

THE COMMENTS PROVIDED ARE PRELIMINARY AND ARE NOT TO BE ASSUMED AS A COMPLETE REVIEW OF THE PROPOSAL. DURING THE DEVELOPMENT PACKAGE REVIEW PROCESS, A FULL REVIEW WILL BE MADE BY THE SITE LANDSCAPE/NPPO REVIEW SECTION TO ENSURE COMPLIANCE WITH THE APPLICABLE CITY OF TUCSON UNIFIED DEVELOPMENT CODE, TECHNICAL STANDARDS MANUAL AND ADMINISTRATIVE MANUAL REQUIREMENTS FOR SITE LANDSCAPE, NATIVE PLANTS AND RAINWATER HARVESTING.

SITE LANDSCAPE/NPPO COMMENTS:

1. No comments or concerns with regard to this loading dock and tenant improvement project.

Thank you.
Chad Keller, PLA
Landscape Architect
chad.keller@tucsonaz.gov
520.837.4923
Site Zoning * REVIEW COMPLETED CDRC TRANSMITTAL

TO:
Planning & Development Services Department

FROM: Fernando L. García
Site Zoning Review Section

PROJECT:
4570 N Oracle Rd, Tucson, AZ 85705
Parcel: 10511061A
Pre-Submittal Conference
TP-PRE-0226-00052

TRANSMITTAL DATE: March 19, 2026

1. The proposed development must comply with the City of Tucson Unified Development Code (UDC) Administrative Manual Chapter 2-06 – Development Package. Building permits can be submitted and reviewed concurrently with the development package but the building plans cannot be approved until the development package is approved and the building plans are reviewed for consistency.

2. The zoning for this parcel is C-3. The proposed use is “Retail Land Use Group – General Merchandise Sales”, a permitted use in this zone.

3. As the proposal shows the elimination of motor vehicle parking spaces, the development package will be required to submit an updated parking calculations table for the full Tucson Mall site demonstrating that, with the reduction of parking spaces, it still provides the minimum required parking.

4. Although the site itself is legal nonconforming, any changes and improvements to the site, including to the motor vehicle use area, must abide by current code. Motor vehicle area design is subject to compliance with UDC Article 7.4.6.

5. Clearly indicate that a long-haul trailer is able to safely maneuver from a public street to the proposed loading area without impeding traffic off or on-site or otherwise negatively impacting other improvements on site, including landscaping.

6. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package/Tentative Plat review process, the Site Zoning Review Section will conduct a full review to assure compliance with applicable UDC development criteria and technical standards.

7. If you have any questions, please contact me at fernando.garcia2@tucsonaz.gov.
TW New Area Development * REVIEW COMPLETED Based on the information provided, Tucson Water has no objections to the proposed development.
If new domestic, irrigation, or fire water services are required for the development, please contact Tucson Water’s New Services Section at 520-791-5164 or via email at TW_Common@tucsonaz.gov.
These comments are based on the limited preliminary information provided by the applicant and should not be considered a comprehensive review of the proposed project. Any questions or concerns regarding these comments should be directed to Kathryn Gerber, Engineering Manager, at Kathryn.Gerber@tucsonaz.gov