Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: TP-PRE-0226-00048
Parcel: 123020840

Address:
2526 E GRANT RD

Review Status: Approved

Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1

Plan Number - TP-PRE-0226-00048
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
Fire New Construction * REVIEW COMPLETED TP-PRE-0226-00048 • Pre-Application Conference Review v1 • 2526 E GRANT RD TUCSON, AZ 85716:
Based on the information provided, TFD has the following comments:
1. Existing exterior patio does not appear to be permitted.
2. Any commercial building plans should reference the IEBC, or fire sprinklers will be required.
Questions: patricia.shelton@tucsonaz.gov
ROW Engineering Review * REVIEW COMPLETED DTM -Standard Comments based on the scope of work
1) Any work to be performed or required with in the City Right of Way will require Separate and individual ROW permit per scope of work.
2) With notation that Sidewalk and Driveways are property owners responsibility. All damaged or missing sidewalk plans or driveway panels should be repairs or replaced to maintain safety.
3) Note that proposed property does fall within the Grant Rd Widening zone 5 & 6 and may require coordination and review by the City Project Manage at the time of submission and construction. There is currently No projected Start date for Grant Rd Zone 5 & 6 widening project. Please refer to City of Tucson Web page, Department of Transportation section under https://cotgis.maps.arcgis.com/apps/dashboards/0edb305f30a34520b2e7015648a89744
https://www.grantroad.info/
4) On DP insure that you show Future Right of Way line for you project area.

Zane.Swenson@Tucsonaz.gov
Site Engineering * REVIEW COMPLETED Permit Activity Number: TP-PRE-0226-00048
Project: Restaurant remodel, and unpermitted patio
Location: 2526 E GRANT RD
Review Date: 3/11/2026
Reviewer: Dylan Molina – Engineering Associate – Site Engineering
Related Cases: TC-COM-1225-02337

*This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code.*
City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes

Site Engineering Review Comments:
1. A development package still needed to cover the unpermitted work from patio – patio adds to expansion total. Expansion <25%, however unpermitted patio changed previous parking configuration which does require submission and approval of a DP.
2. DP needs to be approved before building permit (TC-COM-1225-02337) can be approved by Site Engineering.
3. Please be advised, that future ROW must be shown on DP – provide sight visibility triangles for current and future ROW.


This review is for Pre-Application purposes. Please be aware that additional comments may be forthcoming during submission process.
If you have any questions or concerns, please contact Dylan Molina at Dylan.Molina@tucsonaz.gov.
Site Landscape * REVIEW COMPLETED PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
REVIEWER: CHAD KELLER, RLA
SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION

PROJECT: REMODELING AN EXISTING RESTAURANT; UN-PERMITTED PATIO AREA
ACTIVITY NO: TP-PRE-0226-00048
ADDRESS: 2526 E GRANT RD
ZONING: COMMERCIAL ZONE (C-2)
03.09.2026

THE COMMENTS PROVIDED ARE PRELIMINARY AND ARE NOT TO BE ASSUMED AS A COMPLETE REVIEW OF THE PROPOSAL. DURING THE DEVELOPMENT PACKAGE REVIEW PROCESS, A FULL REVIEW WILL BE MADE BY THE SITE LANDSCAPE/NPPO REVIEW SECTION TO ENSURE COMPLIANCE WITH THE APPLICABLE CITY OF TUCSON UNIFIED DEVELOPMENT CODE, TECHNICAL STANDARDS MANUAL AND ADMINISTRATIVE MANUAL REQUIREMENTS FOR SITE LANDSCAPE, NATIVE PLANTS AND RAINWATER HARVESTING.

SITE LANDSCAPE/NPPO COMMENTS:

1. Site landscape has no comments or concerns about this restaurant remodel.

Thank you.
Chad Keller, PLA
Landscape Architect
chad.keller@tucsonaz.gov
520.837.4923
Site Zoning * REVIEW COMPLETED CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review
FROM: Georgia Pennington, Lead Planner
PROJECT: Thursday Pre-submittal meeting TP-PRE-0226-00048

Parcel(s): 123020840
Zoning: C-2
Existing Use: Food Service
Proposed Use: Food Service
TRANSMITTAL DATE: 3/3/26

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 – Development Package. The Development Package is a separate submittal from the building permits, and the building permits cannot be approved until the Development Package is approved.
2. The existing zone is C-2. Food Service is permitted in C-3, subject to 4.9.4.M.1 and 4.9.13.P
3. Maximum Height: 75’
4. Setbacks:
a. 10’ from Grant
b. 0’ adjacent to non-residential zoning
5. Motor Vehicle Space requirements (7.4.4):
1 space per 100 sq. ft. GFA and outdoor seating areas.
For reductions/exceptions please visit 7.4.5 of the UDC.
6. Parking Area Access Lanes (PAAL) shall be 24 feet wide for 2-way traffic and fire access.
7. Comply with Section 7-01 Pedestrian Access in the Technical Standards Manual for new construction.
8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions, please contact me at Georgia.Pennington@tucsonaz.gov.
TW New Area Development * REVIEW COMPLETED Based on the information provided, Tucson Water has no objections to the proposed development.
The property currently receives water service through one meter, size (5/8-inch). The service is connected to an 8-inch Cement Asbestos water main (B Zone) located on the north side of the parcel ROW (E Grant Rd). Water pressure in this area is 67-74 PSI at an elevation of 2428 ft. Water pressure can vary by an additional 5 psi +/-.
There is an existing 8-inch fire hydrant right in front of the parcel.
If any new domestic water, irrigation water, or fire water services are needed to serve this proposed development, please contact Tucson Water’s New Services Section by calling 520-791-5164 or by sending an email to TW_Common@tucsonaz.gov.
The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to Kathryn Gerber (Engineering Manager) at Kathryn.Gerber@tucsonaz.gov.