Plan Review Detail
Review Status: Approved
Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1
Plan Number - TP-PRE-0224-00040
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Fire New Construction | REVIEW COMPLETED | TP-PRE-0224-00040 • Pre-Application Conference Review v1 • 124 N MELWOOD AV TUCSON, AZ 85745: Based on the information provided, TFD has the following comments: 1. Will need to provide fire apparatus access following 2018 IFC, 503. Questions: patricia.shelton@tucsonaz.gov / 520.837.7082 |
|||
| ROW Engineering Review | REVIEW COMPLETED | No Comments David Stiffey David.Stiffey@tucsonaz.gov |
|||
| Site Engineering | REVIEW COMPLETED | 1. Because the site has been previously altered from its original subdivision, it must be split as a minor subdivision. Lianne Evans lianne.evans@tucsonaz.gov |
|||
| Site Landscape | REVIEW COMPLETED | CDRC TRANSMITTAL PROJECT: RESIDENTIAL LOT SPLIT AT 124 N MELWOOD AVENUE ACTIVITY NO. TP-PRE-0224-00030 ADDRESS: 124 N MELWOOD AVENUE ZONING: R-2 1. No landscape comments currently. If you have any questions about these comments, I can be reached at chad.keller@tucsonaz.gov |
|||
| Site Zoning | REVIEW COMPLETED | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Nathan Herrera- Planner PROJECT: Thursday Pre-submittal meeting - TP-PRE-0224-00040 Address: Parcel 116-18-185B Zoning: R-2 Existing Use: Single Family Proposed Use: Minor Subdivision TRANSMITTAL DATE: March 07, 2024 COMMENTS: 1. Per UDC Article 11.4.20, A subdivision is defined a, “Any division of land, improved or unimproved, for the purpose of financing, sales, or lease, whether immediate or future: Any property whose boundaries are fixed by a recorded plat, which is divided into more than two parts.” 2. The proposed lot split of the property meets the definition of a subdivision and will require Minor Subdivision process. Information on the Minor Subdivision process can be found in UDC Article 8.4.3, and the Administrative Manual Section 2-07.0.0. 3. Per UDC Table 6.3-2.A, the minimum lot size in the R2 zone is 5,000 square feet. All proposed lots will need to be a minimum 5,000 square feet. 4. A Supplemental Site Plan showing the current location of structures on the property will be required with the Minor Subdivision submittal to ensure compliance with R2 zoning setback and height standards. Per UDC Table 6.3-2.A, the required setbacks are the greater of 6 feet or 2/3 the height of the building wall. The maximum allowable height in the R2 zone is 25 feet. 5. Per UDC Article 6.6.3.C, Detached accessory buildings, including accessory dwelling units, are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line. Accessory Dwelling Units (ADU) must comply with this requirement. In the R-2 zone a unit is allowed for every 2,904 square feet of property. If the proposed new lot is at least 5,808 square feet two independent units would be permitted, and ADU rules would not have to be followed. 6. Per UDC Article 7.4.6.K.A.2, An alley, when used for access, must be a minimum of 20 feet wide, free of obstructions, and surfaced with a dust control method that is acceptable to the Tucson Department of Transportation and Mobility. The alley that off of Melwood Ave, that provides access to the parcel is only 16 feet wide and is not able to act as the primary access to the parcel. 7. Any development of the property, or proposed property, that would result in 3 or more units on a single parcel will require a Development Package process. Development Package submittals must comply with the Administrative Manual Section 2-06 - Development Package. More information on the Development Package process can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Development-Package 8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions about this transmittal, contact me at Nathan.Herrera@tucsonaz.gov |
|||
| TW New Area Development | REVIEW COMPLETED | TP-PRE-0224-00040 - Pre-Application Conference Review v1 – 124 N MELWOOD AV Tucson Water offers the following comments for your convenience: 1. The proposed lot configurations do not meet the requirements of Tucson Water’s Remote Meter Policy No. IV-B.08, Eff. 07/14/2009. To comply with Tucson Water’s Remote Meter Policy, each of the proposed lots must have a minimum of 15’ of real property frontage onto a public or private street, public alley, or a public utility or water easement granted to the City of Tucson that contains a water line that can serve the lot. The easternmost lot does not have such real property frontage. And, an easement to the street is not real property frontage. 2. There is an existing 6” cement asbestos water main on the west side of Melwood Avenue constructed under Plan Number 044-1986 in 1986. 3. To keep this proposed lot configuration, the Applicant will need to construct approximately 200’ of new 4” water main in the alley on the south side of the property from the above referenced water main to the new lot line. 4. A copy of the ‘as-built’ plans referenced in these comments may be obtained from Tucson Water’s Mapping & GIS Center by sending an e-mail request for them to TWMapInfo@tucsonaz.gov. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |