Plan Review Detail
Review Status: Approved
Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1
Plan Number - TP-PRE-0125-00017
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Fire New Construction | REVIEW COMPLETED | TP-PRE-0125-00017 • Pre-Application Conference Review v1 • 2102 N DRAGOON ST TUCSON, AZ 85745: Based on the information provided, TFD has no comments at this time. Questions: patricia.shelton@tucsonaz.gov / 520.837.7082 |
|||
| ROW Engineering Review | REVIEW COMPLETED | DTM has no comments. | |||
| Site Engineering | REVIEW COMPLETED | TP-PRE-0125-00017 2102 N DRAGOON Site Engineering has no comments or objections. Chris Arrington chris.arrington@tucsonaz.gov |
|||
| Site Landscape | REVIEW COMPLETED | CDRC TRANSMITTAL PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, RLA SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: INTERIOR REMODEL, TWO ADDITIONS AND MINOR EXTERIOR IMPROVEMENTS OF AN EXISTING FREE-STANDING FIRE STATION BUILDING BY THE CITY OF TUCSON ACTIVITY NO: TP-PRE-0125-00017 ADDRESS: 2102 N DRAGOON ST ZONING: L-I LIGHT INDUSTRIAL ZONE This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to ensure compliance with the applicable UDC development criteria and Technical Standards. SITE LANDSCAPE/NPPO COMMENTS: 1. Provide protective fencing at the drip line of the existing trees to the west of the new 571 SF addition. This will protect the tree roots from being compacted which could damage or kill the tree. 2. No other comments or concerns with these additions to the site. Thank you. Chad Keller, RLA Landscape Architect chad.keller@tucsonaz.gov 520.837.4923 |
|||
| Site Zoning | REVIEW COMPLETED | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Loran Shamis; Principal Planner PROJECT: TP-PRE-0125-00017 Address: 2102 N Dragoon St Parcel(s): 11519004S Zoning: I-1 Existing Use: Protective Services Proposed Use: Protective Services TRANSMITTAL DATE: February 13, 2025 COMMENTS: 1. The proposed development must comply with this checklist for Minor Changes to Existing Commercial/Industrial Sites - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/minor_changes_to_commercial_industrial_sites_.pdf 2. The site is zoned I-1 and the proposed use is civic – protective services (government owned and operated) which is permitted (UDC Table 4.8-5). 3. The minimum setback requirement to Dragoon Avenue is 20’ from the property line (UDC 6.4.5.C). The minimum setback requirement for nonresidential use adjacent to nonresidential zones is 0’ (UDC Table 6.3-5.A). 4. Per UDC 7.4.2.E, if an expansion is less than 25% or a series of expansions cumulatively results in less than 25% expansion in floor area, the requirements of Section 7.4 apply only to the proposed expansions. 5. The minimum parking requirement is 1 space per 300 square feet of gross floor area (UDC Table 7.4.4-1). 6. The minimum bicycle parking requirement is 1 short-term space per 8,000 sq. ft. GFA, minimum requirement is 2 spaces; and 1 space per 12,000 sq. ft. GFA, minimum requirement is 2 spaces (UDC Table 7.4.8-1) 7. Provide a pedestrian circulation path that connects all areas of development and to any adjacent street frontage. The path must be ADA accessible and a minimum of 4’ wide (TSM 7-01). 8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at Loran.Shamis@tucsonaz.gov. |
|||
| TW New Area Development | REVIEW COMPLETED | TP-PRE-0125-00017 - Pre-Application Conference Review v1 – 2102 N DRAGOON ST Tucson Water has no objections to the proposed development and offers the following comment for your convenience: 1. If any new domestic water, irrigation water, or fire water services are needed to serve this proposed development, please contact Tucson Water’s New Services Section by calling 520-791-5164 or by sending an email to TW_Common@tucsonaz.gov. The above comment is based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about this comment may be directed to: Michael Asbury, Engineering Associate Tucson Water, New Development Section 201 N. Stone Avenue, #2 Flr. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2202 michael.asbury@tucsonaz.gov |