| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Fire New Construction | REVIEW COMPLETED | TP-PRE-0125-00003 • Pre-Application Conference Review v1 • 2934 S COTTONWOOD LN TUCSON, AZ 85713: Based on the information provided, TFD has no comments at this time. Questions: patricia.shelton@tucsonaz.gov / 520.837.7082 |
|||
| ROW Engineering Review | REVIEW COMPLETED | DTM has no comments. | |||
| Site Engineering | REVIEW COMPLETED | TP-PRE-0125-00003 2934 S COTTONWOOD LN Site engineering comments are as follows: 1. Include ingress / egress access recording information on the plat that shows legal access from Cottonwood Lane. 2. Ensure the final plat meets the requirements of Administrative Manual 2-07. Ryan Insalaco – ryan.insalaco@tucsonaz.gov |
|||
| Site Landscape | REVIEW COMPLETED | CDRC TRANSMITTAL PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, RLA SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: MINOR SUBDIVISION TO SPLIT LOT INTO TWO PARCELS ACTIVITY NO: TP-PRE-0125-00003 ADDRESS: 2934 S COTTONWOOD LN ZONING: R-1 RESIDENCE ZONE This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to ensure compliance with the applicable UDC development criteria and Technical Standards. SITE LANDSCAPE/NPPO COMMENTS: 1. Prior to development of the new sites in the future, a NPPO or a NPPO Waiver will be required. 2. No other comments or concerns with the proposal to split the lot into two parcels. If you have any questions about these comments, I can be reached at chad.keller@tucsonaz.gov |
|||
| Site Zoning | REVIEW COMPLETED | CDRC TRANSMITTAL TO: Planning & Development Services Department FROM: Fernando L. García PDSD Zoning Review Section PROJECT: 2934 S Cottonwood Ln, Tucson, AZ 85713 Parcel(s): 119-18-024J Zoning: R-1 Pre-Submittal Conference (1st Review) TP-PRE-0125-00003 TRANSMITTAL DATE: January 30, 2025 1. The proposed development must comply with the City of Tucson Unified Development Code (UDC) Administrative Manual Chapter 2-06 – Development Package. Building permits can be submitted and reviewed concurrently with the development package but the building plans cannot be approved until the development package is approved and the building plans are reviewed for consistency. 2. This land division would have to be submitted as a “tentative/final plat” application 3. This parcel is zoned R-1. The minimum lot size is 7,000 sf, which would allow one single-family residence on the lot, or 10,000 sf, which would allow two on the lot. 4. The building setback requirements from any new parcel lines would be 6’ or 2/3 the height of the adjacent structure’s walls, whichever is greater. Were new parcel lines to be proposed within this setback area, a Design Development Option (DDO) or Board of Adjustment variance may be necessary to request the reduced setbacks prior to approval of the land division. For more information about the DDO or Board of Adjustment variance process, reach out to Georgia Pennington at georgia.pennington@tucsonaz.gov or 520-837-6311. 5. Per UDC Section 7.8.4.C, “if access is provided by an easement and the easement serves more than two single-family homes the City may require the easement to be developed as a street or as a parking area access lane (PAAL). The City has received numerous inquiries regarding potential further land division for other properties that utilize this easement. Given the probable increased density, as well as need for public services, development of this easement to street standard from S Cottonwood Ln to the parcel may be required. PDSD is undergoing discussion with other City Departments to make a determination as to whether this easement will require improvement to street standard per UDC 7.8.4.C. 6. No permit was found for the structure labeled as “garage” on proposed Parcel 2. An expired permit for which inspections were not completed – permit T07CM00241 from 2007 (https://pro.tucsonaz.gov/permitdetails/T07CM00241/) – includes plans that show a “ramada” in that location. A permit utilizing as-built plans would be required to be submitted and approved before this land division could be approved. 7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, the Zoning Review Section will conduct a full review to assure compliance with applicable UDC development criteria and technical standards. 8. The ingress/egress easement is written so as to exclude the subject parcel. This verbiage essentially terminates the easement at the parcel, preventing it from continuing westward. Please correct the access easement and provide proof of recordation with Pima County. 9. If you have any questions, please contact me at fernando.garcia2@tucsonaz.gov. |
|||
| TW New Area Development | REVIEW COMPLETED | Pre-Application Conference Review v1 - TP-PRE-0125-00003- 2934 S COTTONWOOD LN Tucson Water has no objections to the proposed development and offers the following comments for your convenience: 1. Each lot will need to have its own water meter. No sharing of water meters will be allowed. 2. After the proposed property split the north lot can be served by the 6 inch PVC potable water main to the north. This existing potable water main lies in the center of a 30 foot wide water and ingress/egress easement where a water meter can be installed 15 feet away from said potable water main. 3. The south lot is already being served by a water meter. 4. If any new domestic water, irrigation water, or fire water services are needed to serve this proposed development, please contact Tucson Water’s New Services Section by calling 520-791-5164 or by sending an email to TW_Common@tucsonaz.gov. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Michael Asbury, Engineering Associate Tucson Water, New Development Section 201 N. Stone Avenue, #2 Flr. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2202 michael.asbury@tucsonaz.gov |