Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Plan Number: TP-PRE-0124-00007
Parcel: 13817032A

Address:
302 E CORONA RD

Review Status: Approved

Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1

Plan Number - TP-PRE-0124-00007
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
Fire New Construction REVIEW COMPLETED TP-PRE-0124-00007 • Pre-Application Conference Review v1 • 302 E CORONA RD TUCSON, AZ 85756:
Based on the information provided, TFD has no comments at this time.
Questions: patricia.shelton@tucsonaz.gov / 520.837.7082
ROW Engineering Review REVIEW COMPLETED TP-PRE-0124-00007
302 E. Corona Rd.

Comments:
1. A PIA is going to be required for this project. https://www.tucsonaz.gov/tdot/private-improvement-agreement Contact TDOT Engineering for information. DOT-Engineering-Review-Section@tucsonaz.gov Or call. 520-791-5100 Jesus Villezcas
2. Please provide the PIA number for approval of the DP

David Stiffey
DTM Project Coordinator
David.Stiffey@tucsonaz.gov
Site Engineering REVIEW COMPLETED 1.The project is within a 100-year flood hazard zone and may not be eligible for a minor subdivision (UDC 8.4.3.B.6). A hydrology report done by a registered professional engineer will be required to determine whether this flood hazard zone is a regulatory floodplain. If the hazard is a regulatory floodplain, it is not eligible for a minor subdivision.
2. Lots 4 and 5 are within a recognized flood hazard area. Any work done in the flood hazard area will require a floodplain use permit, and any buildings must be elevated one foot above the flood hazard elevation (the flood hazard elevation is 6 inches above existing grade).

Lianne Evans
lianne.evans@tucsonaz.gov
Site Landscape REVIEW COMPLETED ACTIVITY NO. TP-PRE-0124-00007
ADDRESS/PARCEL: 138-17-032A
ZONING: R-2

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.
The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to assure compliance with the applicable UDC development criteria and Technical Standards.

COMMENTS:
1. There must be a NPPO or NPPO waiver. An NPPO is required per UDC 7.7.3-B. A Native Plant Preservation Plan, Section 7.7.4, is required to be submitted or approved or a request for an exception from the Native Plant Preservation requirements approved in accordance with Sections 7.7.3.D.3 & .4 of the UDC and Admin. Manual Section 2-11.0.0 prior to Grading Plan approval.

If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov or 520-837-4988
Site Zoning REVIEW COMPLETED CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Wyatt Berger, Lead Planner

PROJECT: Thursday Pre-application Conference – TP-PRE-0124-00007
Address: 302 and 322 East Corona Road
Parcel(s): 138-17-032A
Zoning: R-2 “Residential”
Existing Use: Undeveloped
Proposed Use: Single-family residential (minor subdivision)

TRANSMITTAL DATE: January 24, 2024

COMMENTS:
1. The project is within a 100-year regulatory floodplain area or erosion hazard setback and is not eligible for a minor subdivision (UDC 8.4.3.B.6). A tentative plat and a final plat are required for this proposal.

2. Development must comply with Administrative Manual Sections 2-06 and 2-07. Building permits may be applied for concurrently with the tentative and final plats; however, the tentative and final plats must be approved prior to zoning approval of any associated building permits.

3. A single-family residence is a permitted use in the R-2 zone, subject to use-specific standards 4.9.7.B.6, .9, and .10.

4. Per UDC Table 6.3-2.A, when a residential use is adjacent to a residential zone, the required perimeter yard is six feet or 2/3 the height of the exterior building wall, whichever is greater. Front street and side street perimeter yards appear to be met.

5. The maximum permitted lot coverage in the R-2 zone is 70% (UDC Table 6.3-2.A).

6. A portion of the site is within the Airport Hazard District for the TIA Environs. The proposed maximum building heights do not exceed the height limitations by the Airport Hazard Districts.

7. Minimum lot size requirements are met with the proposal.

8. Ensure access standards found in Section 7.8 of the UDC and Sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met.

9. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions, please contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951.
TW New Area Development REVIEW COMPLETED TP-PRE-0124-00007 - Pre-Application Conference Review v1 – 302 E CORONA RD

Tucson Water has no objections to the proposed development and offers the following comments for your convenience:

1. There is an existing 8” cement asbestos public water main in Corona Road constructed in 1965 under Plan No. PN 037-1965, and existing 6” public water mains of various materials in Geronimo Avenue that the single-family residential lots in this project may connect to. See Tucson Water’s SE131513 valve map for additional details.

2. Tucson Water no longer allows split connections to it’s water mains. Each of the proposed lots will need to have its own water service line from the water main to the water meter.’

3. Copies of the valve map(s) and ‘as-built’ plans referenced in these comments may be obtained from Tucson Water’s Mapping & GIS Center by sending an e-mail request for them to TWMapInfo@tucsonaz.gov.

The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov