Review Date Reviewer's Name Type of Review Description Status Comments
Site Zoning REVIEW COMPLETED CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review
FROM: Nathan Herrera, Planner
PROJECT: Thursday Pre-submittal meeting - TP-PRE-0123-00099
Address: 9139 E 22nd St, Tucson, AZ. 85710
Zoning: C-1
Existing Use: Residential-Single Family Detached
Proposed Use: Personal Storage
TRANSMITTAL DATE: April 13, 2023

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. A separate building permit and demolition permit will be needed. The Development Package will need to be approved before a building permit can be issued.
3. On development package submittal please clarify the current use, and proposed use of the property (i.e. Personal Storage, Single Family Residential with Personal Storage as an accessory use?).
a. Refer to Table 4.8.6 of the Unified Development Code to determine permitted uses within the C-1 zone and identify which use you are proposing.
4. See UDC Section 4.9.10.C & 4.9.13.O for Use Specific Standards for the Personal Storage Use in the C-1 zone.
5. Commercial vehicular and bicycle parking requirements will be required for a commercial use. See UDC Section 7.4.4 and 7.4.8 for requirements.
a. Access standards for commercial developments can be found in section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual.
b. Ensure ADA parking requirements are met per International Building Code standards.
6. In the C-1 zone non-residential uses to non-residential zones have setbacks the greater of 0’, or 1 ½ H of the proposed exterior wall. Non-residential uses to residential uses have setbacks the greater of 1 ½ H of the proposed exterior wall. Residential uses to non-residential uses have setbacks the greater of 10’ or ¾ H of the proposed exterior wall.
7. Per UDC Section 6.3-4.B, Personal Storage has a height limit of 16’ in the C-1 Zone.