Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Plan Number: TP-PRE-0123-00087
Parcel: 113071920
Review Status: Approved
Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1
Plan Number - TP-PRE-0123-00087
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
Fire New Construction | REVIEW COMPLETED | Building shall be classified as a R-2 occupancy (apartment/rental units); therefore, fire sprinklers shall be installed in the building. Questions: Jennifer Peel-Davis Tucson Fire Department Fire Plans Examiner Fire Inspector I, II and Fire Alarm Plans Examiner Jennifer.Peel-Davis@Tucsonaz.gov Desk: 520-837-7033 |
|||
Site Engineering | REVIEW COMPLETED | TP-PRE-0123-00087 1548 E HEDRICK DR Comments: 1. Please show waste stream calculations on your development plans. 2. Ensure the dumpster enclosure has a 25 ft vertical clearance and is free of power lines. (TSM 8-01.5.3) 3. A Floodplain Use Permit and elevation certificate will be required. 4. Please clarify the intriguingly titled imaginary property line. 5. If the imaginary line is a planned future lot split, this lot can be split as it has not been previously subdivided (and you would need a trash enclosure on each lot). Faffs Riederer Faffs.riederer@tucsonaz.gov |
|||
Site Landscape | REVIEW COMPLETED | CDRC TRANSMITTAL PROJECT: CHERRY PLACE BLDG 4 REPLACEMENT ACTIVITY NO. TP-PRE-0123-00087 ADDRESS/PARCEL: 1548 E HEDRICK DR/113-07-1920 ZONING: R-2 This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to assure compliance with the applicable UDC development criteria and Technical Standards. COMMENTS: 1. Due to size of the expansion, Landscape/NPPO has no comments on this project. If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov or 520-837-4988 |
|||
Site Zoning | REVIEW COMPLETED | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Georgia Pennington, Planner PROJECT: TP-PRE-0123-00087 Parcel(s): 113-07-1920 Current Zoning: R-2 Existing Use: Multifamily Development Proposed Use: Multifamily Development COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 – Development Package. The Development Package is a separate submittal from the building permits, and the building permits cannot be approved until the Development Package is approved. 2. The existing zone is R-2. Multifamily Development is a permitted use in the R-2 zone, subject to use-specific standards 4.9.7.B.6, .9 & .10. 3. Maximum Height: 25 Feet 4. Maximum Density: 15 Dwelling Units/Acre 5. Setbacks: a. Front Street: 20 feet or 1.5 height of proposed exterior building wall, whichever is greater b. Side Street: 10 feet c. Side/Rear: 10 feet or 2/3 height of proposed exterior building wall, whichever is greater A Design Development Option will need to be approved for the reduced east side setback. 6. Motor Vehicle Space requirements: a. 2 space/Dwelling Unit (for 2-bedroom units) 7. Bicycle Parking Requirements: a. Short term: 0.10 spaces per bedroom (min 2) b. Long term: .5 spaces per bedroom (min 2) 8. Electric Vehicle Charging Requirements: a. EV Ready- 10% required; EV Capable- 20%, 9. Parking Area Access Lanes (PAAL) shall be 24 feet wide for 2-way traffic and fire access. 10. Comply with Section 7-01 Pedestrian Access in the Technical Standards Manual for new construction. 11. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at Georgia.Pennington@tucsonaz.gov. |
|||
Traffic Engineering Review | REVIEW COMPLETED | No Comments | |||
TW Hydraulic Modeling Review | REVIEW COMPLETED | 1. Tucson Water has no objections to, or comments on, the proposed development. 2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |