Permit Review Detail
Review Status: Requires Resubmit
Review Details: FIRE OPERATIONAL REVIEW v.1
Permit Number - TF-FOP-0825-01140
Review Name: FIRE OPERATIONAL REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/10/2025 | Fire Code Enforcement Fast | IN REVIEW | |||
| 09/10/2025 | Commercial Structural Express | REQUIRES RESUBMIT | ACTIVITY NO. TF-FOP-0825-01140 ADDRESS/PARCEL: (1148 N MAIN AV TUCSON, AZ 85705) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. COMMENTS: 1. Per emails and voicemails sent to you, please see the example attached to the email of submittals to be submitted. The City of Tucson is looking for ways to speed the review process, however… we did not get a response from you. 2. Floor Plan (For inspection purposes by Tucson Fire Department) a. Please submit a floor plan containing the following. i. LOCATE/LABEL THE FOLLOWING ON THE PLAN: 1. LIGHTED EXIT LIGHTS WITH POWER BACKUP 2. EMERGENCY LIGHTS WITH POWER BACKUP 3. FIRE EXTINGUISHERS 4. NO SMOKING 5. ELECTRIC POWER GENERATOR(S) - IF USED 3. NOTE: Structural members size Calculations exhibits and Anchoring System used shall be sealed/signed/dated by an Arizona licensed Structural Engineer. 4. Awnings & canopies shall comply to the fire propagation performance criteria Test 1 or 2 of NFPA 701 and Flame Spread Index not greater than 25 per ASTM E84 or UL 723 and comply to NFPA 286 per IBC 3105.3 a. Please submit documentation. 5. Anchoring System used. a. No information of the anchoring system used. i. Please submit exhibit drawings. ii. If stakes are used. 1. Provide length and diameter of stake. a. Provide resistance capacity. 2. Provide how many stakes per post. a. Provide calculation on total resistance. b. Provide lateral forces to be resisted by the anchoring system at each post. b. No information as to how the structure is anchored onto soil/earth. i. Please submit exhibit drawings. c. No post bottom plate information. i. Please submit exhibit drawings. 6. Please resubmit. Should you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976 |
||
| 08/28/2025 | TFD Application Completeness Check Express | REVIEW COMPLETED |