Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TE-FPU-1124-00417
Parcel: 125122500

Review Status: Requires Resubmit

Review Details: FLOODPLAIN USE REVIEW v.2

Permit Number - TE-FPU-1124-00417
Review Name: FLOODPLAIN USE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/03/2025 Site Engineering REQUIRES RESUBMIT 1. Owner contacted 2.3.25 regarding cost estimate. Garage can be considered a separate structure given breezeway. If the garage will be considered a separate structure: a) please revise the cost estimate by removing all garage materials and labor, and b) please show flood vents within 1 foot of grade level that provide at least 1 square inch of venting per 1 square foot of garage, or provide a minimum finished floor elevation (FFE) of 2485.68ft NAVD88 for the garage.

Mike Ortiz
michael.ortiz@tucsonaz.gov