Permit Review Detail
Review Status: Requires Resubmit
Review Details: FLOODPLAIN USE REVIEW v.1
Permit Number - TE-FPU-1123-00378
Review Name: FLOODPLAIN USE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/06/2023 | Site Engineering | REQUIRES RESUBMIT | Indicate on the plans that the finished floor elevation is going to be one foot or higher than the base flood elevation of 2496.86 feet elevation. The elevation of the building must be certified by a registered land surveyor at two points during building: first before the pre-slab inspection, when the foundation forms are up, and second when construction is nearly complete, before any final inspections can take place. There will be holds put on the building permits that prevent these inspections until the elevation certificates are submitted to the floodplain use permit in the TDC Online portal. Lianne Evans lianne.evans@tucsonaz.gov |