Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TE-FPU-1025-00390
Parcel: 138041240

Review Status: Requires Resubmit

Review Details: FLOODPLAIN USE REVIEW v.1

Permit Number - TE-FPU-1025-00390
Review Name: FLOODPLAIN USE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/05/2025 Site Engineering REQUIRES RESUBMIT Permit: TE-FPU-1025-00390
Location: 934 W CALLE MEDINA
Review Date: 11/05/2025

Residential Engineering comments:
The structure resides in a FEMA AE Flood Zone.
The current estimate of the Full Cash Value (FCV) of the home and property is $170,302 according to the Pima County Assessor. We look at 65% of FCV to determine value of property ($170,302 x 65% = $110,696.30)

The proposed home addition and remodel quote is $73,950. The estimated maximum value for this project to remain “Non-Substantial” is $55,348.15. If the increase in the value of the structure is over the non-substantial threshold, the entire structure may need to be brought to current floodplain standards.
There are a few options:
1. Provide a cost estimate from the contractor that is lower than the substantial threshold (< $55,247.)

2. Provide an appraisal for the structure in excess of two times the cost estimate of the project.

3. Provide documentation from a registered land surveyor that the finished floor of the existing structure is already at or above 2488.5-ft NAVD88.

If you have any questions or concerns, please contact
Dylan Molina
Dylan.Molina@tucsonaz.gov