Permit Review Detail
Review Status: Requires Resubmit
Review Details: FLOODPLAIN USE REVIEW v.1
Permit Number - TE-FPU-1025-00390
Review Name: FLOODPLAIN USE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/05/2025 | Site Engineering | REQUIRES RESUBMIT | Permit: TE-FPU-1025-00390 Location: 934 W CALLE MEDINA Review Date: 11/05/2025 Residential Engineering comments: The structure resides in a FEMA AE Flood Zone. The current estimate of the Full Cash Value (FCV) of the home and property is $170,302 according to the Pima County Assessor. We look at 65% of FCV to determine value of property ($170,302 x 65% = $110,696.30) The proposed home addition and remodel quote is $73,950. The estimated maximum value for this project to remain “Non-Substantial” is $55,348.15. If the increase in the value of the structure is over the non-substantial threshold, the entire structure may need to be brought to current floodplain standards. There are a few options: 1. Provide a cost estimate from the contractor that is lower than the substantial threshold (< $55,247.) 2. Provide an appraisal for the structure in excess of two times the cost estimate of the project. 3. Provide documentation from a registered land surveyor that the finished floor of the existing structure is already at or above 2488.5-ft NAVD88. If you have any questions or concerns, please contact Dylan Molina Dylan.Molina@tucsonaz.gov |