Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TE-FPU-1024-00356
Parcel: 12512079C

Review Status: Requires Resubmit

Review Details: FLOODPLAIN USE REVIEW v.1

Permit Number - TE-FPU-1024-00356
Review Name: FLOODPLAIN USE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/31/2024 Site Engineering REQUIRES RESUBMIT 1. The proposed FFE of 2469.0 is not sufficient. Arizona law requires 1 foot of freeboard above the base flood elevation. The base flood elevation at the building location is 2468.97ft NAVD88. The minimum FFE for the building is 2470ft NAVD88. Show a sufficient FFE on the plans for this resubmittal as well as the development package resubmittal.

Mike Ortiz
michael.ortiz@tucsonaz.gov