Permit Number: TE-FPU-1024-00336
Parcel: 110072790

Review Status: Requires Resubmit

Review Details: FLOODPLAIN USE REVIEW v.1

Permit Number - TE-FPU-1024-00336
Review Name: FLOODPLAIN USE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/21/2024 Site Engineering REQUIRES RESUBMIT 1. The proposed FFE is not sufficient. Interpolation between the 2-ft contours and 11 inches of assumed flooding suggests a BFE of 2433.92ft NAVD88 at the location of the ADU. The minimum FFE would be 2434.92ft NAVD88. Alternatively, the FFE shall be 2 feet above existing grade.