Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: FLOODPLAIN USE REVIEW v.1
Permit Number - TE-FPU-1023-00364
Review Name: FLOODPLAIN USE REVIEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/19/2023 | Site Engineering | REQUIRES RESUBMIT | 1. Please submit a site plan that indicates that the finished floor elevation of the proposed building will be at or higher than 2466.11 feet elevation. The base flood elevation in this location is 2465.11 feet elevation and Arizona State Regulations require that the building be elevated a foot above the base flood elevation. The elevation of the building must be certified by a registered land surveyor at two points during building: first before the pre-slab inspection, when the foundation forms are up, and second when construction is nearly complete, before any final inspections can take place. There will be holds put on the building permits that prevent these inspections until the elevation certificates are submitted to the floodplain use permit in the TDC Online portal. Lianne Evans lianne.evans@tucsonaz.gov |