Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TE-FPU-0926-00392
Parcel: 134240310

Review Status: Requires Resubmit

Review Details: FLOODPLAIN USE REVIEW v.1

Permit Number - TE-FPU-0926-00392
Review Name: FLOODPLAIN USE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/25/2026 Site Engineering REQUIRES RESUBMIT A floodplain use (FPU) permit with elevation certificate has been started for the project related to TC-RES-0326-01375.

A licensed Arizona Civil Engineer must prepare, sign, and stamp a grading plan in accordance with the City of Tucson Technical Standards Manual (TSM) Section 2-01.0.0. The grading plan must include:
1. Existing Conditions: Existing topography with contour intervals (typically 1- or 2-foot), benchmark, and datum reference (NAVD 88).
2. Proposed Grading: Proposed contours and/or spot elevations throughout the site, including at all building corners, parking areas, and drainage structures.
3. Limits of Disturbance: Full extent of all proposed grading work, including all areas associated with required drainage improvements.
4. Cut & Fill Quantities: Total disturbed area (in square feet) and total cut and fill quantities.
5. Cross-Section Detail – South Side (ADU & Perimeter Wall): Provide a north-south cross-section showing the proposed ADU and site disturbance area. Include the clearance distance between the ADU and all adjacent grading fill and perimeter walls to ensure the structure is protected from slope failures or erosion from adjacent fill areas. Show both existing and proposed elevations.
6. Cross-Section Detail – West Side (ADU & Perimeter Wall): Provide a west-east cross-section with the same information as above.
7. Floodplain Compliance: The base flood elevation (BFE) of 2597.0-FT NAVD88, was determined using contours of the property and a regulatory finished floor must be (at a minimum) FFE =2598.0-FT NAVD88. NOTE: If a more conservative elevation is determined by the engineer, then that value will be used.