Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TE-FPU-0926-00386
Parcel: 140442040

Review Status: Requires Resubmit

Review Details: FLOODPLAIN USE REVIEW v.1

Permit Number - TE-FPU-0926-00386
Review Name: FLOODPLAIN USE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/23/2026 Site Engineering REQUIRES RESUBMIT Site Engineering Review

TE-FPU-0926-00386
6017 E FARMSTEAD DR

Date of Transmittal: 9/23/2026

Description: Three Room Addition
Reference: TC-RES-0926-05025

City of Tucson Code:
https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes

Final Plat for Wilmot Farms Lots 1 thru 121, Book 49, Page 74, Sequence Number 97107342
https://gis.pima.gov/maps/subdiv/select.cfm?null=&bkpg=49074&seqnum=97107342

Site Engineering comments are as follows:

1. This parcel, Lot 113 of the Wilmot Farms subdivision, is subject to floodplain regulations. [General Note 14 Final Plat for Wilmot Farms Lots 1 thru 121, Book 49, Page 74, Sequence Number 97107342]
2. A floodplain use (FPU) permit has been created on your behalf and resubmittal of the FPU will be required.
3. Provide pictures and descriptions of the shade cover materials over the horse shades for the resubmittal of the FPU. It must be determined whether the structures add to impervious cover. Pictures and descriptions of the vertical construction materials are also required to be resubmitted to the FPU in order to determine whether the structures “reduce the flow capacity of the channels.” [General Note 12 Final Plat for Wilmot Farms Lots 1 thru 121, Book 49, Page 74, Sequence Number 97107342]
4. Provide total impervious lot coverage calculations on the next submittal of the site. This includes the proposed permitted areas, as well as all unpermitted impervious covering. The structures along the north, (the shed, shipping container, and horse shades), as well as the concrete apron which appears on aerial imagery in 2022 all contribute to this calculation. “Exceeding the 7% impervious coverage is a violation of Floodplain Regulations and may only be remedied by removing the excess impervious cover and restoring the disturbed area to its predeveloped natural condition.” [General Note 13 Final Plat for Wilmot Farms Lots 1 thru 121, Book 49, Page 74, Sequence Number 97107342]
5. Note 8.14 of the Covenants, Conditions, and Restrictions document for Wilmot Farms defers back to the plat and may be found at sequence number 97107343 of the Pima County Recorder’s office.
6. Additional comments may be forthcoming depending on the content of files submitted for subsequent review cycles.

*Please submit revised drawings along with a detailed response letter stating how each resubmittal comment has been addressed*

To re-submit, visit the Tucson Development Center Online at:
https://tdc-online.tucsonaz.gov/#/home

Engineering Associate: Ryan Insalaco
ryan.insalaco@tucsonaz.gov