Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TE-FPU-0926-00361
Parcel: 126061800

Review Status: Requires Resubmit

Review Details: FLOODPLAIN USE REVIEW v.1

Permit Number - TE-FPU-0926-00361
Review Name: FLOODPLAIN USE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/04/2026 Site Engineering REQUIRES RESUBMIT Site Engineering Review

TE-FPU-0926-00361
720 N LONGFELLOW AV

Date of Transmittal: 9/4/2026

Description: Conversion of existing residence into an assisted living home. Including accessible ramp and accessible restroom.

City of Tucson Code:
https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes

Site Engineering comments are as follows:

1. This Floodplain Use (FPU) Permit, TE-FPU-0926-00361, was created on the applicant’s behalf because the project exists within a COT recognized floodplain associated with the Alvernon Wash. This project cost adds to the Substantial Improvement calculation and needs to address the following:
2. The contractor must provide a detailed cost estimate in accordance with Substantial Improvement and Substantial Damage (SI/SD) requirements. The cost estimate must be submitted on official company/contractor letterhead and shall itemize all costs associated with the proposed scope of work, broken down into separate line items including, but not limited to:
• Labor (all trades)
• Materials and Equipment
• Overhead and Profit
• Warranties, Permits, and Fees

3. NOTE: the added fire protection for sprinklers must be included. This can be provided as an additional cost estimate if it was completed by a separate contractor and it will also add to the Substantial Improvement Calculation.
4. The cost estimate must reflect the full market value cost to complete the proposed work. Estimates that reflect only partial scopes, discounted rates, or owner-supplied labor must still account for the fair market value of all work performed. NOTE: Lease agreements, payment plans, financing agreements, or any other financial instrument will not be accepted as a substitute for a bona fide contractor cost estimate.
5. Please only provide a finalized cost estimate document file to this FPU permit.
6. The added improvement may exceed the 50% threshold for Substantial Improvement based on the value of the structure per the Pima County Assessor’s data. To remain within floodplain compliance the cost for improvements must remain under 50% OR the structure must comply with the regulatory floor elevation. Should the improvements exceed the 50% threshold, we will discuss options to remain in compliance with City of Tucson Floodplain Regulation.
7. The required cost estimate must be submitted and approved prior to TC-COM-0826-01297 receiving final approval and issuance.

To re-submit, visit the Tucson Development Center Online at:
https://tdc-online.tucsonaz.gov/#/home

Engineering Associate: Ryan Insalaco
ryan.insalaco@tucsonaz.gov